{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/13510"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/13510","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Design criteria for DC link filters in a synchronous generator-phase controlled rectifier-filter-load system","abstract":"Power electronics have advanced to the point that they can be considered for use in large, high power dc electrical distribution systems. The proposed Navy DC Zonal Electrical Distribution System (DC ZEDS) being designed for the new DD-21 utilizes a rectified ac generator output which is filtered and stepped to usable voltages by local dc-dc converters. One characteristic of the high bandwidth converters is a negative input impedance, which when coupled with an LC input filter, can lead to system instabilities. This thesis examines various stability criteria for determining parameters of the dc link filter. Comparisons between a simplified system model, a model using subsystem impedances and an Advanced Continuous Simulation Language (ACSL) model of a reduced order system are made. Simulations were conducted to verify the validity of the stability criteria. The ACSL model provides an extremely useful tool in evaluating the response of various system parameters to changes in design values. The design criteria examined in this thesis can be ultimately used to provide design specifications to future vendors.","abstract_html":"Power electronics have advanced to the point that they can be considered for use in large, high power dc electrical distribution systems. The proposed Navy DC Zonal Electrical Distribution System (DC ZEDS) being designed for the new DD-21 utilizes a rectified ac generator output which is filtered and stepped to usable voltages by local dc-dc converters. One characteristic of the high bandwidth converters is a negative input impedance, which when coupled with an LC input filter, can lead to system instabilities. This thesis examines various stability criteria for determining parameters of the dc link filter. Comparisons between a simplified system model, a model using subsystem impedances and an Advanced Continuous Simulation Language (ACSL) model of a reduced order system are made. Simulations were conducted to verify the validity of the stability criteria. The ACSL model provides an extremely useful tool in evaluating the response of various system parameters to changes in design values. The design criteria examined in this thesis can be ultimately used to provide design specifications to future vendors.","abstract_has_math":false,"creators":["Greseth, Gregory J."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S. in Electrical Engineering","degree_level":"Masters","degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Ciezki, John G.","Ashton, Robert W."],"committee_chairs":[],"committee_members":[],"year":1999,"date_issued":"1999-06","date_published":"1999-06","updated_at":"2026-11-26T00:17:29Z","subjects":[],"languages":[],"rights":["Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/13510","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/13510","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F13510","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F13510","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ciezki, John G.","Ashton, Robert W."]},{"key":"dc:creator","label":"Author","values":["Greseth, Gregory J."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["June, 1999"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-09-07T15:34:33Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-09-07T15:34:33Z"]},{"key":"dc:date.issued","label":"Date","values":["1999-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Electrical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/13510"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Power electronics have advanced to the point that they can be considered for use in large, high power dc electrical distribution systems. The proposed Navy DC Zonal Electrical Distribution System (DC ZEDS) being designed for the new DD-21 utilizes a rectified ac generator output which is filtered and stepped to usable voltages by local dc-dc converters. One characteristic of the high bandwidth converters is a negative input impedance, which when coupled with an LC input filter, can lead to system instabilities. This thesis examines various stability criteria for determining parameters of the dc link filter. Comparisons between a simplified system model, a model using subsystem impedances and an Advanced Continuous Simulation Language (ACSL) model of a reduced order system are made. Simulations were conducted to verify the validity of the stability criteria. The ACSL model provides an extremely useful tool in evaluating the response of various system parameters to changes in design values. The design criteria examined in this thesis can be ultimately used to provide design specifications to future vendors."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/designcriterifor1094513510"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["viii, 107 p.;28 cm."]},{"key":"dc:title","label":"Title","values":["Design criteria for DC link filters in a synchronous generator-phase controlled rectifier-filter-load system"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["U.S. Navy (U.S.N.) author."]}]}],"canonical_facts":{"dc:contributor.advisor":["Ciezki, John G.","Ashton, Robert W."],"dc:creator":["Greseth, Gregory J."],"dc:date":["June, 1999"],"dc:date.accessioned":["2012-09-07T15:34:33Z"],"dc:date.available":["2012-09-07T15:34:33Z"],"dc:date.issued":["1999-06"],"dc:description.abstract":["Power electronics have advanced to the point that they can be considered for use in large, high power dc electrical distribution systems. The proposed Navy DC Zonal Electrical Distribution System (DC ZEDS) being designed for the new DD-21 utilizes a rectified ac generator output which is filtered and stepped to usable voltages by local dc-dc converters. One characteristic of the high bandwidth converters is a negative input impedance, which when coupled with an LC input filter, can lead to system instabilities. This thesis examines various stability criteria for determining parameters of the dc link filter. Comparisons between a simplified system model, a model using subsystem impedances and an Advanced Continuous Simulation Language (ACSL) model of a reduced order system are made. Simulations were conducted to verify the validity of the stability criteria. The ACSL model provides an extremely useful tool in evaluating the response of various system parameters to changes in design values. The design criteria examined in this thesis can be ultimately used to provide design specifications to future vendors."],"dc:description.uri":["http://archive.org/details/designcriterifor1094513510"],"dc:format.extent":["viii, 107 p.;28 cm."],"dc:identifier.uri":["https://hdl.handle.net/10945/13510"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["Approved for public release; distribution is unlimited."],"dc:title":["Design criteria for DC link filters in a synchronous generator-phase controlled rectifier-filter-load system"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["U.S. Navy (U.S.N.) author."],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Electrical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-26T00:17:29Z"}