{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/14036"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/14036","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Design and construction of instrumentation for investigating the optical dispersion of gases by infrared interferometry","abstract":"The design and construction of a modified Rayleigh Interferometer and allied systems was undertaken at the U. S. Naval Postgraduate School by Lieutenant Commander William G, Eaton, USN, and Captain Frederick H. Thomas, USAF. The inherent weakness of low radiation intensity associated with Rayleigh type interferometers, especially in the infrared region, when measuring the refractive indices of gases led to the design and construction of a multi-chambered refTactometer . The theory of this design was based on the gain in intensity achieved by multiple slit interferometry Optical components, capable of allowing investigation in the infrared region between one and 25 microns, were installed in the optical system. The vacuum and gas admission system, which provides a pressure differential of at least one atmosphere, incorporates fractional distillation for gas purification. Time limitations prohibited an actual determination of the index of refraction of a gas with this system, however, it is hoped that future investigations will be made utilizing this instrumentation, and that the results justify the theoretical forecast.","abstract_html":"The design and construction of a modified Rayleigh Interferometer and allied systems was undertaken at the U. S. Naval Postgraduate School by Lieutenant Commander William G, Eaton, USN, and Captain Frederick H. Thomas, USAF. The inherent weakness of low radiation intensity associated with Rayleigh type interferometers, especially in the infrared region, when measuring the refractive indices of gases led to the design and construction of a multi-chambered refTactometer . The theory of this design was based on the gain in intensity achieved by multiple slit interferometry Optical components, capable of allowing investigation in the infrared region between one and 25 microns, were installed in the optical system. The vacuum and gas admission system, which provides a pressure differential of at least one atmosphere, incorporates fractional distillation for gas purification. Time limitations prohibited an actual determination of the index of refraction of a gas with this system, however, it is hoped that future investigations will be made utilizing this instrumentation, and that the results justify the theoretical forecast.","abstract_has_math":false,"creators":["Eaton, William G.","Thomas, Frederick H."],"institution":"Naval Postgraduate School","degree_name":"Master of Science in Physics","degree_level":"Masters","degree_discipline":null,"degree_department":"Physics (PH)","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1959,"date_issued":"1959","date_published":"1959","updated_at":"2026-11-21T22:45:10Z","subjects":["Physics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["ocm10858519"],"render_values":[{"text":"ocm10858519","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/14036","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/14036","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F14036","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F14036","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Physics (PH)"]},{"key":"dc:creator","label":"Author","values":["Eaton, William G.","Thomas, Frederick H."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-10-10T19:57:56Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-10-10T19:57:56Z"]},{"key":"dc:date.issued","label":"Date","values":["1959"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["0966cedc-9b4d-44f6-932d-51786e48444d"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Physics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["ocm10858519"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/14036"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The design and construction of a modified Rayleigh Interferometer and allied systems was undertaken at the U. S. Naval Postgraduate School by Lieutenant Commander William G, Eaton, USN, and Captain Frederick H. Thomas, USAF. The inherent weakness of low radiation intensity associated with Rayleigh type interferometers, especially in the infrared region, when measuring the refractive indices of gases led to the design and construction of a multi-chambered refTactometer . The theory of this design was based on the gain in intensity achieved by multiple slit interferometry Optical components, capable of allowing investigation in the infrared region between one and 25 microns, were installed in the optical system. The vacuum and gas admission system, which provides a pressure differential of at least one atmosphere, incorporates fractional distillation for gas purification. Time limitations prohibited an actual determination of the index of refraction of a gas with this system, however, it is hoped that future investigations will be made utilizing this instrumentation, and that the results justify the theoretical forecast."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/designndconstruc1094514036"]},{"key":"dc:title","label":"Title","values":["Design and construction of instrumentation for investigating the optical dispersion of gases by infrared interferometry"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant Commander, United States Navy","Captain, United States Air Force"]}]}],"canonical_facts":{"dc:contributor.department":["Physics (PH)"],"dc:creator":["Eaton, William G.","Thomas, Frederick H."],"dc:date.accessioned":["2012-10-10T19:57:56Z"],"dc:date.available":["2012-10-10T19:57:56Z"],"dc:date.issued":["1959"],"dc:description.abstract":["The design and construction of a modified Rayleigh Interferometer and allied systems was undertaken at the U. S. Naval Postgraduate School by Lieutenant Commander William G, Eaton, USN, and Captain Frederick H. Thomas, USAF. The inherent weakness of low radiation intensity associated with Rayleigh type interferometers, especially in the infrared region, when measuring the refractive indices of gases led to the design and construction of a multi-chambered refTactometer . The theory of this design was based on the gain in intensity achieved by multiple slit interferometry Optical components, capable of allowing investigation in the infrared region between one and 25 microns, were installed in the optical system. The vacuum and gas admission system, which provides a pressure differential of at least one atmosphere, incorporates fractional distillation for gas purification. Time limitations prohibited an actual determination of the index of refraction of a gas with this system, however, it is hoped that future investigations will be made utilizing this instrumentation, and that the results justify the theoretical forecast."],"dc:description.uri":["http://archive.org/details/designndconstruc1094514036"],"dc:identifier.oclc":["ocm10858519"],"dc:identifier.uri":["https://hdl.handle.net/10945/14036"],"dc:relation.orgunit":["0966cedc-9b4d-44f6-932d-51786e48444d"],"dc:subject.lcsh":["Physics"],"dc:title":["Design and construction of instrumentation for investigating the optical dispersion of gases by infrared interferometry"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant Commander, United States Navy","Captain, United States Air Force"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Physics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T22:45:10Z"}