{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/14101"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/14101","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"The effect of non-sinusoidal impressed voltages on A.C. servo motors","abstract":"In response to a suggestion by the Bureau of Ships, Navy Department, Washington, D. C, investigation as to the effects of non-sinusoidal impressed voltages on the operation of alternating current servo motors was undertaken in October 1954 at the Electrical Engineering Laboratory, U.S. Naval Postgraduate School, Monterey, California. Inter-related with the effects of non-sinusoidal impressed voltages are the effects of space harmonics of magneto-motive force, the latter producing such phenomena as asynchronous crawling and sub-synchronous locking. Bearing this in mind, an effort was made to detect adverse effects upon the operation of several two-phase induction servo motors which might be attributable to either time or space harmonics, or possibly a combination of the two. The motors tested were standard production models except where one modification was made in an endeavor to specifically create an unfavorable design situation. The results of this investigation indicated that wave form, balanced or unbalanced, had no seriously adverse effect upon the torque-speed characteristics of the motors tested. This might have been anticipated of production models where design features would certainly tend to eliminate or minimize such effects.","abstract_html":"In response to a suggestion by the Bureau of Ships, Navy Department, Washington, D. C, investigation as to the effects of non-sinusoidal impressed voltages on the operation of alternating current servo motors was undertaken in October 1954 at the Electrical Engineering Laboratory, U.S. Naval Postgraduate School, Monterey, California. Inter-related with the effects of non-sinusoidal impressed voltages are the effects of space harmonics of magneto-motive force, the latter producing such phenomena as asynchronous crawling and sub-synchronous locking. Bearing this in mind, an effort was made to detect adverse effects upon the operation of several two-phase induction servo motors which might be attributable to either time or space harmonics, or possibly a combination of the two. The motors tested were standard production models except where one modification was made in an endeavor to specifically create an unfavorable design situation. The results of this investigation indicated that wave form, balanced or unbalanced, had no seriously adverse effect upon the torque-speed characteristics of the motors tested. This might have been anticipated of production models where design features would certainly tend to eliminate or minimize such effects.","abstract_has_math":false,"creators":["Busey, Charles W.","Barton, William R.,"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Electrical Engineering","degree_level":"Masters","degree_discipline":null,"degree_department":"Electrical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1955,"date_issued":"1955","date_published":"1955","updated_at":"2026-11-19T06:04:39Z","subjects":["Mechanical engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["ocn640309345"],"render_values":[{"text":"ocn640309345","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/14101","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/14101","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F14101","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Electrical Engineering"]},{"key":"dc:creator","label":"Author","values":["Busey, Charles W.","Barton, William R.,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-10-10T19:58:22Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-10-10T19:58:22Z"]},{"key":"dc:date.issued","label":"Date","values":["1955"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Electrical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Mechanical engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["ocn640309345"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/14101"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In response to a suggestion by the Bureau of Ships, Navy Department, Washington, D. C, investigation as to the effects of non-sinusoidal impressed voltages on the operation of alternating current servo motors was undertaken in October 1954 at the Electrical Engineering Laboratory, U.S. Naval Postgraduate School, Monterey, California. Inter-related with the effects of non-sinusoidal impressed voltages are the effects of space harmonics of magneto-motive force, the latter producing such phenomena as asynchronous crawling and sub-synchronous locking. Bearing this in mind, an effort was made to detect adverse effects upon the operation of several two-phase induction servo motors which might be attributable to either time or space harmonics, or possibly a combination of the two. The motors tested were standard production models except where one modification was made in an endeavor to specifically create an unfavorable design situation. The results of this investigation indicated that wave form, balanced or unbalanced, had no seriously adverse effect upon the torque-speed characteristics of the motors tested. This might have been anticipated of production models where design features would certainly tend to eliminate or minimize such effects."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/theeffectofnonsi1094514101"]},{"key":"dc:title","label":"Title","values":["The effect of non-sinusoidal impressed voltages on A.C. servo motors"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.department":["Electrical Engineering"],"dc:creator":["Busey, Charles W.","Barton, William R.,"],"dc:date.accessioned":["2012-10-10T19:58:22Z"],"dc:date.available":["2012-10-10T19:58:22Z"],"dc:date.issued":["1955"],"dc:description.abstract":["In response to a suggestion by the Bureau of Ships, Navy Department, Washington, D. C, investigation as to the effects of non-sinusoidal impressed voltages on the operation of alternating current servo motors was undertaken in October 1954 at the Electrical Engineering Laboratory, U.S. Naval Postgraduate School, Monterey, California. Inter-related with the effects of non-sinusoidal impressed voltages are the effects of space harmonics of magneto-motive force, the latter producing such phenomena as asynchronous crawling and sub-synchronous locking. Bearing this in mind, an effort was made to detect adverse effects upon the operation of several two-phase induction servo motors which might be attributable to either time or space harmonics, or possibly a combination of the two. The motors tested were standard production models except where one modification was made in an endeavor to specifically create an unfavorable design situation. The results of this investigation indicated that wave form, balanced or unbalanced, had no seriously adverse effect upon the torque-speed characteristics of the motors tested. This might have been anticipated of production models where design features would certainly tend to eliminate or minimize such effects."],"dc:description.uri":["http://archive.org/details/theeffectofnonsi1094514101"],"dc:identifier.oclc":["ocn640309345"],"dc:identifier.uri":["https://hdl.handle.net/10945/14101"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:subject.lcsh":["Mechanical engineering"],"dc:title":["The effect of non-sinusoidal impressed voltages on A.C. servo motors"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Electrical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:04:39Z"}