{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/14409"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/14409","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"A maser stabilized K-band signal generator.","abstract":"A stable K-band signal generator which uses an ammonia beam maser as a reference is described. The signal generator has a stability of one part in 10⁷ over periods of one hour or more and one part in 10⁸ for shorter periods. Improved circuitry in the i-f portions of the stabilization loop would give stabilities of one part in 10⁹ or better. The tuning range of the signal generator is from two megacycles per second below the reference signal to two megacycles per second above the reference. A technique for Q measurements on high Q cavities using the signal generator is discussed and the results of three such measurements are reported. A method for measuring the gain of a maser amplifier to within 0.5 db using the signal generator is presented and some preliminary results are reported. Several other applications of the signal generator are considered.","abstract_html":"A stable K-band signal generator which uses an ammonia beam maser as a reference is described. The signal generator has a stability of one part in 10⁷ over periods of one hour or more and one part in 10⁸ for shorter periods. Improved circuitry in the i-f portions of the stabilization loop would give stabilities of one part in 10⁹ or better. The tuning range of the signal generator is from two megacycles per second below the reference signal to two megacycles per second above the reference. A technique for Q measurements on high Q cavities using the signal generator is discussed and the results of three such measurements are reported. A method for measuring the gain of a maser amplifier to within 0.5 db using the signal generator is presented and some preliminary results are reported. Several other applications of the signal generator are considered.","abstract_has_math":false,"creators":["Garner, William G."],"institution":"Naval Postgraduate School","degree_name":"M.S. in Engineering Electronics","degree_level":"Masters","degree_discipline":"electrical engineering","degree_department":"Electronics","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1959,"date_issued":"1959","date_published":"1959","updated_at":"2026-11-21T23:32:18Z","subjects":["Electronics"],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/14409","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/14409","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F14409","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F14409","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Electronics"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Garner, William G."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1959"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-10-10T20:00:09Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-10-10T20:00:09Z"]},{"key":"dc:date.issued","label":"Date","values":["1959"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["electrical engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Engineering Electronics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Electronics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/14409"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A stable K-band signal generator which uses an ammonia beam maser as a reference is described. The signal generator has a stability of one part in 10⁷ over periods of one hour or more and one part in 10⁸ for shorter periods. Improved circuitry in the i-f portions of the stabilization loop would give stabilities of one part in 10⁹ or better. The tuning range of the signal generator is from two megacycles per second below the reference signal to two megacycles per second above the reference. A technique for Q measurements on high Q cavities using the signal generator is discussed and the results of three such measurements are reported. A method for measuring the gain of a maser amplifier to within 0.5 db using the signal generator is presented and some preliminary results are reported. Several other applications of the signal generator are considered."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/amaserstabilized1094514409"]},{"key":"dc:title","label":"Title","values":["A maser stabilized K-band signal generator."]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Captain, United States Marine Corps"]}]}],"canonical_facts":{"dc:contributor.department":["Electronics"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Garner, William G."],"dc:date":["1959"],"dc:date.accessioned":["2012-10-10T20:00:09Z"],"dc:date.available":["2012-10-10T20:00:09Z"],"dc:date.issued":["1959"],"dc:description.abstract":["A stable K-band signal generator which uses an ammonia beam maser as a reference is described. The signal generator has a stability of one part in 10⁷ over periods of one hour or more and one part in 10⁸ for shorter periods. Improved circuitry in the i-f portions of the stabilization loop would give stabilities of one part in 10⁹ or better. The tuning range of the signal generator is from two megacycles per second below the reference signal to two megacycles per second above the reference. A technique for Q measurements on high Q cavities using the signal generator is discussed and the results of three such measurements are reported. A method for measuring the gain of a maser amplifier to within 0.5 db using the signal generator is presented and some preliminary results are reported. Several other applications of the signal generator are considered."],"dc:description.uri":["http://archive.org/details/amaserstabilized1094514409"],"dc:identifier.uri":["https://hdl.handle.net/10945/14409"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.lcsh":["Electronics"],"dc:title":["A maser stabilized K-band signal generator."],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Captain, United States Marine Corps"],"thesis:degree_discipline":["electrical engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Engineering Electronics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T23:32:18Z"}