{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/14412"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/14412","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Measurement of boron in boron-iron by danger coefficient method","abstract":"It has been proposed that the danger coefficient method be used with a low power research reactor to measure minute quantities of boron in iron-boron alloys. An investigation of the limits and accuracy of detection of boron in iron was undertaken using five iron-boron alloys containing different concentrations of boron. Samples of various sizes were introduced in turn into the AGN-201 reactor and the resulting changes in reactivity were determined. A change in reactivity of 4.62 x 10(-8) per microgram of boron was found. The method is sensitive to a change in reactivity of +/- 1.1 x 10(-6) for the AGN-201 reactor, giving a threshold of detection of 23.8 micrograms of boron under the experimental conditions employed. The relative error in the determination of boron content decreases with increasing sample size or boron concentration. The method offers a marked improvement in accuracy of measurement of low concentrations of boron-in-iron over that of conventional techniques. Extension of the methods employed here might be used for more complex ferrous alloys such as boron-steels.","abstract_html":"It has been proposed that the danger coefficient method be used with a low power research reactor to measure minute quantities of boron in iron-boron alloys. An investigation of the limits and accuracy of detection of boron in iron was undertaken using five iron-boron alloys containing different concentrations of boron. Samples of various sizes were introduced in turn into the AGN-201 reactor and the resulting changes in reactivity were determined. A change in reactivity of 4.62 x 10(-8) per microgram of boron was found. The method is sensitive to a change in reactivity of +/- 1.1 x 10(-6) for the AGN-201 reactor, giving a threshold of detection of 23.8 micrograms of boron under the experimental conditions employed. The relative error in the determination of boron content decreases with increasing sample size or boron concentration. The method offers a marked improvement in accuracy of measurement of low concentrations of boron-in-iron over that of conventional techniques. Extension of the methods employed here might be used for more complex ferrous alloys such as boron-steels.","abstract_has_math":false,"creators":["Carew, Thomas E.","Mow, Douglas F."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Physics","degree_level":"Masters","degree_discipline":null,"degree_department":"Physics (PH)","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1958,"date_issued":"1958","date_published":"1958","updated_at":"2026-11-21T22:32:13Z","subjects":["Physics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["ocn640309121"],"render_values":[{"text":"ocn640309121","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/14412","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/14412","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F14412","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F14412","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Physics (PH)"]},{"key":"dc:creator","label":"Author","values":["Carew, Thomas E.","Mow, Douglas F."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-10-10T20:00:10Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-10-10T20:00:10Z"]},{"key":"dc:date.issued","label":"Date","values":["1958"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["0966cedc-9b4d-44f6-932d-51786e48444d"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Physics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["ocn640309121"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/14412"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["It has been proposed that the danger coefficient method be used with a low power research reactor to measure minute quantities of boron in iron-boron alloys. An investigation of the limits and accuracy of detection of boron in iron was undertaken using five iron-boron alloys containing different concentrations of boron. Samples of various sizes were introduced in turn into the AGN-201 reactor and the resulting changes in reactivity were determined. A change in reactivity of 4.62 x 10(-8) per microgram of boron was found. The method is sensitive to a change in reactivity of +/- 1.1 x 10(-6) for the AGN-201 reactor, giving a threshold of detection of 23.8 micrograms of boron under the experimental conditions employed. The relative error in the determination of boron content decreases with increasing sample size or boron concentration. The method offers a marked improvement in accuracy of measurement of low concentrations of boron-in-iron over that of conventional techniques. Extension of the methods employed here might be used for more complex ferrous alloys such as boron-steels."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/measurementofbor1094514412"]},{"key":"dc:title","label":"Title","values":["Measurement of boron in boron-iron by danger coefficient method"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Major, Infantry, United States Army","Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.department":["Physics (PH)"],"dc:creator":["Carew, Thomas E.","Mow, Douglas F."],"dc:date.accessioned":["2012-10-10T20:00:10Z"],"dc:date.available":["2012-10-10T20:00:10Z"],"dc:date.issued":["1958"],"dc:description.abstract":["It has been proposed that the danger coefficient method be used with a low power research reactor to measure minute quantities of boron in iron-boron alloys. An investigation of the limits and accuracy of detection of boron in iron was undertaken using five iron-boron alloys containing different concentrations of boron. Samples of various sizes were introduced in turn into the AGN-201 reactor and the resulting changes in reactivity were determined. A change in reactivity of 4.62 x 10(-8) per microgram of boron was found. The method is sensitive to a change in reactivity of +/- 1.1 x 10(-6) for the AGN-201 reactor, giving a threshold of detection of 23.8 micrograms of boron under the experimental conditions employed. The relative error in the determination of boron content decreases with increasing sample size or boron concentration. The method offers a marked improvement in accuracy of measurement of low concentrations of boron-in-iron over that of conventional techniques. Extension of the methods employed here might be used for more complex ferrous alloys such as boron-steels."],"dc:description.uri":["http://archive.org/details/measurementofbor1094514412"],"dc:identifier.oclc":["ocn640309121"],"dc:identifier.uri":["https://hdl.handle.net/10945/14412"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.orgunit":["0966cedc-9b4d-44f6-932d-51786e48444d"],"dc:subject.lcsh":["Physics"],"dc:title":["Measurement of boron in boron-iron by danger coefficient method"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Major, Infantry, United States Army","Lieutenant, United States Navy"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Physics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T22:32:13Z"}