{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/14538"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/14538","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Pumpability of aircraft turbine lubricants at low temperatures","abstract":"Questions regarding the principles governing flow characteristics of lubricating oils in the vicinity of the pour point have led to an investigation into the behavior of a series of typical aircraft gas turbine lubricants in a simple system at temperatures down to —70 F. The lubricants tested in- cluded two oils of military specification MIL-O-6081B (a 1005 grade and a 1010 grade), a sample equivalent in other properties to 1005 grade but having a — 15 F. pour point, di(2-ethylhexyl) sebacate, and an SAE lOW motor oil with a — 30 F. pour point. Results indicated that laminar flow relationships were satisfactory for predicting flow characteristics down to the pour point so long as proper attention was paid to pump inlet conditions. In addition, there was evidence that fluids with so-called waxy pour points could be satisfactorily pumped to temperatures lower than the pour point, a conclusion which may be of significance.","abstract_html":"Questions regarding the principles governing flow characteristics of lubricating oils in the vicinity of the pour point have led to an investigation into the behavior of a series of typical aircraft gas turbine lubricants in a simple system at temperatures down to —70 F. The lubricants tested in- cluded two oils of military specification MIL-O-6081B (a 1005 grade and a 1010 grade), a sample equivalent in other properties to 1005 grade but having a — 15 F. pour point, di(2-ethylhexyl) sebacate, and an SAE lOW motor oil with a — 30 F. pour point. Results indicated that laminar flow relationships were satisfactory for predicting flow characteristics down to the pour point so long as proper attention was paid to pump inlet conditions. In addition, there was evidence that fluids with so-called waxy pour points could be satisfactorily pumped to temperatures lower than the pour point, a conclusion which may be of significance.","abstract_has_math":false,"creators":["Bridges, J.H.","Starkman, E.S."],"institution":"University of California, Berkeley","degree_name":"M.S. in Engineering","degree_level":"Masters","degree_discipline":"Petroleum","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1954,"date_issued":"1954","date_published":"1954","updated_at":"2026-11-19T06:04:46Z","subjects":["Aeronautics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["ocm640306374"],"render_values":[{"text":"ocm640306374","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/14538","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/14538","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F14538","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F14538","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Bridges, J.H.","Starkman, E.S."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-10-10T20:00:51Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-10-10T20:00:51Z"]},{"key":"dc:date.issued","label":"Date","values":["1954"]},{"key":"dc:publisher","label":"Institution","values":["University of California, Berkeley"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","Conference Paper"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Petroleum"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of California at Berkeley"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Aeronautics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["ocm640306374"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/14538"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This paper was presented at the ASLE 10th Annual Meeting, Chicago, April 15, 1955."]},{"key":"dc:description.abstract","label":"Abstract","values":["Questions regarding the principles governing flow characteristics of lubricating oils in the vicinity of the pour point have led to an investigation into the behavior of a series of typical aircraft gas turbine lubricants in a simple system at temperatures down to —70 F. The lubricants tested in- cluded two oils of military specification MIL-O-6081B (a 1005 grade and a 1010 grade), a sample equivalent in other properties to 1005 grade but having a — 15 F. pour point, di(2-ethylhexyl) sebacate, and an SAE lOW motor oil with a — 30 F. pour point. Results indicated that laminar flow relationships were satisfactory for predicting flow characteristics down to the pour point so long as proper attention was paid to pump inlet conditions. In addition, there was evidence that fluids with so-called waxy pour points could be satisfactorily pumped to temperatures lower than the pour point, a conclusion which may be of significance."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/pumpabilityofirc1094514538"]},{"key":"dc:title","label":"Title","values":["Pumpability of aircraft turbine lubricants at low temperatures"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:creator":["Bridges, J.H.","Starkman, E.S."],"dc:date.accessioned":["2012-10-10T20:00:51Z"],"dc:date.available":["2012-10-10T20:00:51Z"],"dc:date.issued":["1954"],"dc:description":["This paper was presented at the ASLE 10th Annual Meeting, Chicago, April 15, 1955."],"dc:description.abstract":["Questions regarding the principles governing flow characteristics of lubricating oils in the vicinity of the pour point have led to an investigation into the behavior of a series of typical aircraft gas turbine lubricants in a simple system at temperatures down to —70 F. The lubricants tested in- cluded two oils of military specification MIL-O-6081B (a 1005 grade and a 1010 grade), a sample equivalent in other properties to 1005 grade but having a — 15 F. pour point, di(2-ethylhexyl) sebacate, and an SAE lOW motor oil with a — 30 F. pour point. Results indicated that laminar flow relationships were satisfactory for predicting flow characteristics down to the pour point so long as proper attention was paid to pump inlet conditions. In addition, there was evidence that fluids with so-called waxy pour points could be satisfactorily pumped to temperatures lower than the pour point, a conclusion which may be of significance."],"dc:description.uri":["http://archive.org/details/pumpabilityofirc1094514538"],"dc:identifier.oclc":["ocm640306374"],"dc:identifier.uri":["https://hdl.handle.net/10945/14538"],"dc:publisher":["University of California, Berkeley"],"dc:subject.lcsh":["Aeronautics"],"dc:title":["Pumpability of aircraft turbine lubricants at low temperatures"],"dc:type":["Thesis","Conference Paper"],"dspace:entity.type":["Publication"],"thesis:degree_discipline":["Petroleum"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Engineering"],"thesis:institution_name":["University of California at Berkeley"]},"updated_at":"2026-11-19T06:04:46Z"}