{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/14730"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/14730","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"A total absorption spectrometer for gamma rays","abstract":"A description of a total-absorption spectrometer for gamma rays is given. The spectrometer depends on the Cherenkov radiation emitted in 14 inches of lead glass by the shower electron-positron pairs formed by an incident gamma ray. The Cherenkov radiation is detected only when four photomultiplier s looking at the glass operate in coincidence. The added output of the photomultipliers is analyzed with a ten-channel pulse-height analyzer. The relative pulse-height output of the spectrometer varies linearly as the energy of incident monoenergetic electrons is varied from 42 Mev to 319 Mev. The energy resolution is about 30%. It is believed that the useful range of the spectrometer will extend to several Bev.","abstract_html":"A description of a total-absorption spectrometer for gamma rays is given. The spectrometer depends on the Cherenkov radiation emitted in 14 inches of lead glass by the shower electron-positron pairs formed by an incident gamma ray. The Cherenkov radiation is detected only when four photomultiplier s looking at the glass operate in coincidence. The added output of the photomultipliers is analyzed with a ten-channel pulse-height analyzer. The relative pulse-height output of the spectrometer varies linearly as the energy of incident monoenergetic electrons is varied from 42 Mev to 319 Mev. The energy resolution is about 30%. It is believed that the useful range of the spectrometer will extend to several Bev.","abstract_has_math":false,"creators":["Jester, Malvern H. L."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Physics","degree_level":"Masters","degree_discipline":null,"degree_department":"Physics (PH)","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1955,"date_issued":"1955","date_published":"1955","updated_at":"2026-11-21T22:36:33Z","subjects":["Nuclear physics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["ocm640316929"],"render_values":[{"text":"ocm640316929","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/14730","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/14730","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F14730","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Physics (PH)"]},{"key":"dc:creator","label":"Author","values":["Jester, Malvern H. L."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-10-10T20:01:57Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-10-10T20:01:57Z"]},{"key":"dc:date.issued","label":"Date","values":["1955"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["0966cedc-9b4d-44f6-932d-51786e48444d"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Nuclear physics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["ocm640316929"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/14730"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A description of a total-absorption spectrometer for gamma rays is given. The spectrometer depends on the Cherenkov radiation emitted in 14 inches of lead glass by the shower electron-positron pairs formed by an incident gamma ray. The Cherenkov radiation is detected only when four photomultiplier s looking at the glass operate in coincidence. The added output of the photomultipliers is analyzed with a ten-channel pulse-height analyzer. The relative pulse-height output of the spectrometer varies linearly as the energy of incident monoenergetic electrons is varied from 42 Mev to 319 Mev. The energy resolution is about 30%. It is believed that the useful range of the spectrometer will extend to several Bev."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/atotalbsorptions1094514730"]},{"key":"dc:title","label":"Title","values":["A total absorption spectrometer for gamma rays"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.department":["Physics (PH)"],"dc:creator":["Jester, Malvern H. L."],"dc:date.accessioned":["2012-10-10T20:01:57Z"],"dc:date.available":["2012-10-10T20:01:57Z"],"dc:date.issued":["1955"],"dc:description.abstract":["A description of a total-absorption spectrometer for gamma rays is given. The spectrometer depends on the Cherenkov radiation emitted in 14 inches of lead glass by the shower electron-positron pairs formed by an incident gamma ray. The Cherenkov radiation is detected only when four photomultiplier s looking at the glass operate in coincidence. The added output of the photomultipliers is analyzed with a ten-channel pulse-height analyzer. The relative pulse-height output of the spectrometer varies linearly as the energy of incident monoenergetic electrons is varied from 42 Mev to 319 Mev. The energy resolution is about 30%. It is believed that the useful range of the spectrometer will extend to several Bev."],"dc:description.uri":["http://archive.org/details/atotalbsorptions1094514730"],"dc:identifier.oclc":["ocm640316929"],"dc:identifier.uri":["https://hdl.handle.net/10945/14730"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.orgunit":["0966cedc-9b4d-44f6-932d-51786e48444d"],"dc:subject.lcsh":["Nuclear physics"],"dc:title":["A total absorption spectrometer for gamma rays"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Physics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T22:36:33Z"}