{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/14995"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/14995","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"The experimental design and operation of a rotating wickless heat pipe","abstract":"An experimental rotating wickless heat pipe apparatus was designed and machined. The apparatus includes a rotating heat pipe assembly, test stand, spray cooling assembly, safety shielding, and instrumentation. A revised condensing limit for the operation of the rotating heat pipe was obtained by modifying Ballbeck's Nusselt film condensation theory to include the effects of a thermal resistance in the condenser wall and in the condenser outside surface cooling mechanism. Approximate results, obtained for half-cone angles of 1, 2, and 3 degrees, show that less heat can be removed than originally predicted by Ballback, and that the outside heat transfer coefficient can significantly alter the condensing limit. An improved Nusselt theory was developed which applies for all half-cone angles, and which includes the effects of the thermal resistances in the condenser wall and in the condenser outside surface cooling mechanism. This formulation led to a second-order non-linear differential equation for the film thickness which was numerically integrated using a free-overfall boundary condition at the condenser exit. Results obtained for a half-cone angle of 0 degrees are substantially less than the results obtained from the approximate solution for half-cone degrees of 1, 2, and 3 degrees.","abstract_html":"An experimental rotating wickless heat pipe apparatus was designed and machined. The apparatus includes a rotating heat pipe assembly, test stand, spray cooling assembly, safety shielding, and instrumentation. A revised condensing limit for the operation of the rotating heat pipe was obtained by modifying Ballbeck&#x27;s Nusselt film condensation theory to include the effects of a thermal resistance in the condenser wall and in the condenser outside surface cooling mechanism. Approximate results, obtained for half-cone angles of 1, 2, and 3 degrees, show that less heat can be removed than originally predicted by Ballback, and that the outside heat transfer coefficient can significantly alter the condensing limit. An improved Nusselt theory was developed which applies for all half-cone angles, and which includes the effects of the thermal resistances in the condenser wall and in the condenser outside surface cooling mechanism. This formulation led to a second-order non-linear differential equation for the film thickness which was numerically integrated using a free-overfall boundary condition at the condenser exit. Results obtained for a half-cone angle of 0 degrees are substantially less than the results obtained from the approximate solution for half-cone degrees of 1, 2, and 3 degrees.","abstract_has_math":false,"creators":["Daley, Thomas James"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S. in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Marto, Paul J."],"committee_chairs":[],"committee_members":[],"year":1970,"date_issued":"1970-06","date_published":"1970-06","updated_at":"2026-11-26T00:14:38Z","subjects":["Mechanical engineering"],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/14995","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/14995","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F14995","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F14995","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Marto, Paul J."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School"]},{"key":"dc:creator","label":"Author","values":["Daley, Thomas James"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["June 1970"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-01T22:54:47Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-01T22:54:47Z"]},{"key":"dc:date.issued","label":"Date","values":["1970-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Heat pipe, rotating","Heat pipe, wickless","Film condensation"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/14995"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An experimental rotating wickless heat pipe apparatus was designed and machined. The apparatus includes a rotating heat pipe assembly, test stand, spray cooling assembly, safety shielding, and instrumentation. A revised condensing limit for the operation of the rotating heat pipe was obtained by modifying Ballbeck's Nusselt film condensation theory to include the effects of a thermal resistance in the condenser wall and in the condenser outside surface cooling mechanism. Approximate results, obtained for half-cone angles of 1, 2, and 3 degrees, show that less heat can be removed than originally predicted by Ballback, and that the outside heat transfer coefficient can significantly alter the condensing limit. An improved Nusselt theory was developed which applies for all half-cone angles, and which includes the effects of the thermal resistances in the condenser wall and in the condenser outside surface cooling mechanism. This formulation led to a second-order non-linear differential equation for the film thickness which was numerically integrated using a free-overfall boundary condition at the condenser exit. Results obtained for a half-cone angle of 0 degrees are substantially less than the results obtained from the approximate solution for half-cone degrees of 1, 2, and 3 degrees."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/theexperimentald1094514995"]},{"key":"dc:title","label":"Title","values":["The experimental design and operation of a rotating wickless heat pipe"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant Junior Grade, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Marto, Paul J."],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["Naval Postgraduate School"],"dc:creator":["Daley, Thomas James"],"dc:date":["June 1970"],"dc:date.accessioned":["2012-11-01T22:54:47Z"],"dc:date.available":["2012-11-01T22:54:47Z"],"dc:date.issued":["1970-06"],"dc:description.abstract":["An experimental rotating wickless heat pipe apparatus was designed and machined. The apparatus includes a rotating heat pipe assembly, test stand, spray cooling assembly, safety shielding, and instrumentation. A revised condensing limit for the operation of the rotating heat pipe was obtained by modifying Ballbeck's Nusselt film condensation theory to include the effects of a thermal resistance in the condenser wall and in the condenser outside surface cooling mechanism. Approximate results, obtained for half-cone angles of 1, 2, and 3 degrees, show that less heat can be removed than originally predicted by Ballback, and that the outside heat transfer coefficient can significantly alter the condensing limit. An improved Nusselt theory was developed which applies for all half-cone angles, and which includes the effects of the thermal resistances in the condenser wall and in the condenser outside surface cooling mechanism. This formulation led to a second-order non-linear differential equation for the film thickness which was numerically integrated using a free-overfall boundary condition at the condenser exit. Results obtained for a half-cone angle of 0 degrees are substantially less than the results obtained from the approximate solution for half-cone degrees of 1, 2, and 3 degrees."],"dc:description.uri":["http://archive.org/details/theexperimentald1094514995"],"dc:identifier.uri":["https://hdl.handle.net/10945/14995"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Heat pipe, rotating","Heat pipe, wickless","Film condensation"],"dc:subject.lcsh":["Mechanical engineering"],"dc:title":["The experimental design and operation of a rotating wickless heat pipe"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant Junior Grade, United States Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-26T00:14:38Z"}