{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/15004"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/15004","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Fatigue monitoring of 70-30 copper-nickel.","abstract":"Recent tests by G. L. Rowe indicated the possibility of monitoring fatigue damage of 70-30 copper-nickel by use of a commercial fatigue life gage. The work reported herein, however, which includes tests at cyclic strain levels considerably higher and lower than those used by Rowe , suggests that much more study and development will be required before in-service monitoring will be useful or reliable. Fatigue failure, using initial surface crack formation as a criterion, takes place at low cyclic strain levels with appreciably smaller gage indication than does failure at medium or high cyclic strain levels. It is further noted that ability to detect surface cracks depends greatly upon the expertise of the observer so that a less subjective criterion of failure should be developed.","abstract_html":"Recent tests by G. L. Rowe indicated the possibility of monitoring fatigue damage of 70-30 copper-nickel by use of a commercial fatigue life gage. The work reported herein, however, which includes tests at cyclic strain levels considerably higher and lower than those used by Rowe , suggests that much more study and development will be required before in-service monitoring will be useful or reliable. Fatigue failure, using initial surface crack formation as a criterion, takes place at low cyclic strain levels with appreciably smaller gage indication than does failure at medium or high cyclic strain levels. It is further noted that ability to detect surface cracks depends greatly upon the expertise of the observer so that a less subjective criterion of failure should be developed.","abstract_has_math":false,"creators":["Lash, Franklin Bruce"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S. in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Brock, John E."],"committee_chairs":[],"committee_members":[],"year":1970,"date_issued":"1970-06","date_published":"1970-06","updated_at":"2026-11-26T00:02:49Z","subjects":["Mechanical engineering"],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/15004","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/15004","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F15004","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F15004","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Brock, John E."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Lash, Franklin Bruce"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["June 1970"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-01T22:54:51Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-01T22:54:51Z"]},{"key":"dc:date.issued","label":"Date","values":["1970-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["fatigue","70-30 copper-nickel","S/N fatigue life gage"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/15004"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Recent tests by G. L. Rowe indicated the possibility of monitoring fatigue damage of 70-30 copper-nickel by use of a commercial fatigue life gage. The work reported herein, however, which includes tests at cyclic strain levels considerably higher and lower than those used by Rowe , suggests that much more study and development will be required before in-service monitoring will be useful or reliable. Fatigue failure, using initial surface crack formation as a criterion, takes place at low cyclic strain levels with appreciably smaller gage indication than does failure at medium or high cyclic strain levels. It is further noted that ability to detect surface cracks depends greatly upon the expertise of the observer so that a less subjective criterion of failure should be developed."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/fatiguemonitorin1094515004"]},{"key":"dc:title","label":"Title","values":["Fatigue monitoring of 70-30 copper-nickel."]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant Commander, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Brock, John E."],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Lash, Franklin Bruce"],"dc:date":["June 1970"],"dc:date.accessioned":["2012-11-01T22:54:51Z"],"dc:date.available":["2012-11-01T22:54:51Z"],"dc:date.issued":["1970-06"],"dc:description.abstract":["Recent tests by G. L. Rowe indicated the possibility of monitoring fatigue damage of 70-30 copper-nickel by use of a commercial fatigue life gage. The work reported herein, however, which includes tests at cyclic strain levels considerably higher and lower than those used by Rowe , suggests that much more study and development will be required before in-service monitoring will be useful or reliable. Fatigue failure, using initial surface crack formation as a criterion, takes place at low cyclic strain levels with appreciably smaller gage indication than does failure at medium or high cyclic strain levels. It is further noted that ability to detect surface cracks depends greatly upon the expertise of the observer so that a less subjective criterion of failure should be developed."],"dc:description.uri":["http://archive.org/details/fatiguemonitorin1094515004"],"dc:identifier.uri":["https://hdl.handle.net/10945/15004"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["fatigue","70-30 copper-nickel","S/N fatigue life gage"],"dc:subject.lcsh":["Mechanical engineering"],"dc:title":["Fatigue monitoring of 70-30 copper-nickel."],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant Commander, United States Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-26T00:02:49Z"}