{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/16283"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/16283","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"The operation of rotating non-capillary heat pipes","abstract":"A Nusselt-type analysis was performed for laminar film condensation on the inside of a truncated rotating cone, which included the interfacial shear between the vapor and condensate, the vapor pressure drop, the thermal resistance in the condenser wall, and the condenser exterior cooling mechanism. An approximation of this analysis made it possible to find a numerical solution for small half cone angles greater than zero. A parametric study was performed of this approximate solution for various fluids, RPMs, half cone angles, and exterior heat transfer coefficients. A non-capillary rotating heat pipe containing distilled water as the working fluid was tested. It was rotated at 700, 1400, 2100, and 2800 RPM, and heat transfer rates of the heat pipe were determined experimentally for different vapor saturation temperatures corresponding to electrical power inputs ranging from 1 Kw to 7 Kw. The experimental results showed that the heat pipe performance was influenced by non-condensible gases in the working fluid and suggested that the analytical solution predicted heat transfer rates which were too high.","abstract_html":"A Nusselt-type analysis was performed for laminar film condensation on the inside of a truncated rotating cone, which included the interfacial shear between the vapor and condensate, the vapor pressure drop, the thermal resistance in the condenser wall, and the condenser exterior cooling mechanism. An approximation of this analysis made it possible to find a numerical solution for small half cone angles greater than zero. A parametric study was performed of this approximate solution for various fluids, RPMs, half cone angles, and exterior heat transfer coefficients. A non-capillary rotating heat pipe containing distilled water as the working fluid was tested. It was rotated at 700, 1400, 2100, and 2800 RPM, and heat transfer rates of the heat pipe were determined experimentally for different vapor saturation temperatures corresponding to electrical power inputs ranging from 1 Kw to 7 Kw. The experimental results showed that the heat pipe performance was influenced by non-condensible gases in the working fluid and suggested that the analytical solution predicted heat transfer rates which were too high.","abstract_has_math":false,"creators":["Woodard, John Sanford"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Marto, P.J."],"committee_chairs":[],"committee_members":[],"year":1972,"date_issued":"1972-03","date_published":"1972-03","updated_at":"2026-11-19T06:06:04Z","subjects":["Mechanical engineering"],"languages":[],"rights":["Approved for public release; distribution unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/16283","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/16283","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F16283","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F16283","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Marto, P.J."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Woodard, John Sanford"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-13T23:43:57Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-13T23:43:57Z"]},{"key":"dc:date.issued","label":"Date","values":["1972-03"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Heat Pipe","Film Condensation","Heat Transfer"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/16283"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A Nusselt-type analysis was performed for laminar film condensation on the inside of a truncated rotating cone, which included the interfacial shear between the vapor and condensate, the vapor pressure drop, the thermal resistance in the condenser wall, and the condenser exterior cooling mechanism. An approximation of this analysis made it possible to find a numerical solution for small half cone angles greater than zero. A parametric study was performed of this approximate solution for various fluids, RPMs, half cone angles, and exterior heat transfer coefficients. A non-capillary rotating heat pipe containing distilled water as the working fluid was tested. It was rotated at 700, 1400, 2100, and 2800 RPM, and heat transfer rates of the heat pipe were determined experimentally for different vapor saturation temperatures corresponding to electrical power inputs ranging from 1 Kw to 7 Kw. The experimental results showed that the heat pipe performance was influenced by non-condensible gases in the working fluid and suggested that the analytical solution predicted heat transfer rates which were too high."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/theoperationofro1094516283"]},{"key":"dc:title","label":"Title","values":["The operation of rotating non-capillary heat pipes"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant Commander, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Marto, P.J."],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Woodard, John Sanford"],"dc:date.accessioned":["2012-11-13T23:43:57Z"],"dc:date.available":["2012-11-13T23:43:57Z"],"dc:date.issued":["1972-03"],"dc:description.abstract":["A Nusselt-type analysis was performed for laminar film condensation on the inside of a truncated rotating cone, which included the interfacial shear between the vapor and condensate, the vapor pressure drop, the thermal resistance in the condenser wall, and the condenser exterior cooling mechanism. An approximation of this analysis made it possible to find a numerical solution for small half cone angles greater than zero. A parametric study was performed of this approximate solution for various fluids, RPMs, half cone angles, and exterior heat transfer coefficients. A non-capillary rotating heat pipe containing distilled water as the working fluid was tested. It was rotated at 700, 1400, 2100, and 2800 RPM, and heat transfer rates of the heat pipe were determined experimentally for different vapor saturation temperatures corresponding to electrical power inputs ranging from 1 Kw to 7 Kw. The experimental results showed that the heat pipe performance was influenced by non-condensible gases in the working fluid and suggested that the analytical solution predicted heat transfer rates which were too high."],"dc:description.uri":["http://archive.org/details/theoperationofro1094516283"],"dc:identifier.uri":["https://hdl.handle.net/10945/16283"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["Approved for public release; distribution unlimited."],"dc:subject.keyword":["Heat Pipe","Film Condensation","Heat Transfer"],"dc:subject.lcsh":["Mechanical engineering"],"dc:title":["The operation of rotating non-capillary heat pipes"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant Commander, United States Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:06:04Z"}