{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/1664"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/1664","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Design and implementation of a DSP-based control interface unit (CIU)","abstract":"This research involves the development of a human-body motion tracking system constructed with the use of commercial off-the-shelf (COTS) components. The main component of the system investigated in this thesis is the Control Interface Unit (CIU). The CIU is a component designed to receive data from the magnetic, angular rate, and gravity (MARG) sensors and prepare them to be transmitted through a wireless configuration. A simple and effective algorithm is used to filter the sensor data without singularities, providing the measured attitude in the quaternion form for each human limb. Initial calibration of the MARG sensors is also performed with the use of linear calibrating algorithms. The testing and evaluation of the whole system is performed by MATLABÊ¼ and SIMULINKÊ¼ simulations, and by the realtime visualization using a human avatar designed with the X3D graphics specifications. Through this research, it is discovered that the MARG sensors had to be redesigned to overcome an erratum on the Honeywell magnetometer HMC1051Z data sheet. With the redesigned MARG sensors, the testing results showed that the CIU was performing extremely well. The overall motion tracking system is capable of tracking human body limb motions in real time.","abstract_html":"This research involves the development of a human-body motion tracking system constructed with the use of commercial off-the-shelf (COTS) components. The main component of the system investigated in this thesis is the Control Interface Unit (CIU). The CIU is a component designed to receive data from the magnetic, angular rate, and gravity (MARG) sensors and prepare them to be transmitted through a wireless configuration. A simple and effective algorithm is used to filter the sensor data without singularities, providing the measured attitude in the quaternion form for each human limb. Initial calibration of the MARG sensors is also performed with the use of linear calibrating algorithms. The testing and evaluation of the whole system is performed by MATLABÊ¼ and SIMULINKÊ¼ simulations, and by the realtime visualization using a human avatar designed with the X3D graphics specifications. Through this research, it is discovered that the MARG sensors had to be redesigned to overcome an erratum on the Honeywell magnetometer HMC1051Z data sheet. With the redesigned MARG sensors, the testing results showed that the CIU was performing extremely well. The overall motion tracking system is capable of tracking human body limb motions in real time.","abstract_has_math":false,"creators":["Kavousanos-Kavousanakis, Andreas"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S. in Electrical Engineering","degree_level":"Masters","degree_discipline":"Electrical Engineering","degree_department":"Information Sciences (IS)","school":null,"contributors":[],"advisors":["Yun, Xiaoping"],"committee_chairs":[],"committee_members":["Jenn, David C."],"year":2004,"date_issued":"2004-03","date_published":"2004-03","updated_at":"2026-11-19T06:06:04Z","subjects":[],"languages":[],"rights":["Copyright is reserved by the copyright owner","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/1664","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/1664","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F1664","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Yun, Xiaoping"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Jenn, David C."]},{"key":"dc:contributor.department","label":"Department","values":["Information Sciences (IS)","Electrical and Computer Engineering (ECE)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Graduate School of Engineering and Applied Science (GSEAS)","Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Kavousanos-Kavousanakis, Andreas"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-03-14T17:32:37Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-03-14T17:32:37Z"]},{"key":"dc:date.issued","label":"Date","values":["2004-03"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["74f4d405-0bff-4b6e-9446-edae3a8b11bb","54cbc27e-a8d1-42ce-b932-4ae5aa4d2386","88110183-ea50-46f5-b469-809c1418a16d"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering","Systems Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Electrical Engineering","M.S. in Systems Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["MARG III sensor","Control interface unit (CIU)","One-","Three-","Sixteen-Channel CIU","Avatar","Virtual environment","Virtual training","Immersion","Honeywell","Analog devices","Texas Instruments","Microcontoller","Micromachined sensor","X3D","Java","Xilinx","RS232","Wireless communication","WISER 2400"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Copyright is reserved by the copyright owner","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/1664"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This research involves the development of a human-body motion tracking system constructed with the use of commercial off-the-shelf (COTS) components. The main component of the system investigated in this thesis is the Control Interface Unit (CIU). The CIU is a component designed to receive data from the magnetic, angular rate, and gravity (MARG) sensors and prepare them to be transmitted through a wireless configuration. A simple and effective algorithm is used to filter the sensor data without singularities, providing the measured attitude in the quaternion form for each human limb. Initial calibration of the MARG sensors is also performed with the use of linear calibrating algorithms. The testing and evaluation of the whole system is performed by MATLABÊ¼ and SIMULINKÊ¼ simulations, and by the realtime visualization using a human avatar designed with the X3D graphics specifications. Through this research, it is discovered that the MARG sensors had to be redesigned to overcome an erratum on the Honeywell magnetometer HMC1051Z data sheet. With the redesigned MARG sensors, the testing results showed that the CIU was performing extremely well. The overall motion tracking system is capable of tracking human body limb motions in real time."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/designndimplemen109451664"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xviii, 66 p. : ill. (some col.)"]},{"key":"dc:title","label":"Title","values":["Design and implementation of a DSP-based control interface unit (CIU)"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant Junior Grade, Hellenic Navy"]},{"key":"local:etd.verified","label":"Local Etd Verified","values":["no"]}]}],"canonical_facts":{"dc:contributor.advisor":["Yun, Xiaoping"],"dc:contributor.committeemember":["Jenn, David C."],"dc:contributor.department":["Information Sciences (IS)","Electrical and Computer Engineering (ECE)"],"dc:contributor.other":["Graduate School of Engineering and Applied Science (GSEAS)","Naval Postgraduate School (U.S.)"],"dc:creator":["Kavousanos-Kavousanakis, Andreas"],"dc:date.accessioned":["2012-03-14T17:32:37Z"],"dc:date.available":["2012-03-14T17:32:37Z"],"dc:date.issued":["2004-03"],"dc:description.abstract":["This research involves the development of a human-body motion tracking system constructed with the use of commercial off-the-shelf (COTS) components. The main component of the system investigated in this thesis is the Control Interface Unit (CIU). The CIU is a component designed to receive data from the magnetic, angular rate, and gravity (MARG) sensors and prepare them to be transmitted through a wireless configuration. A simple and effective algorithm is used to filter the sensor data without singularities, providing the measured attitude in the quaternion form for each human limb. Initial calibration of the MARG sensors is also performed with the use of linear calibrating algorithms. The testing and evaluation of the whole system is performed by MATLABÊ¼ and SIMULINKÊ¼ simulations, and by the realtime visualization using a human avatar designed with the X3D graphics specifications. Through this research, it is discovered that the MARG sensors had to be redesigned to overcome an erratum on the Honeywell magnetometer HMC1051Z data sheet. With the redesigned MARG sensors, the testing results showed that the CIU was performing extremely well. The overall motion tracking system is capable of tracking human body limb motions in real time."],"dc:description.uri":["http://archive.org/details/designndimplemen109451664"],"dc:format.extent":["xviii, 66 p. : ill. (some col.)"],"dc:identifier.uri":["https://hdl.handle.net/10945/1664"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.orgunit":["74f4d405-0bff-4b6e-9446-edae3a8b11bb","54cbc27e-a8d1-42ce-b932-4ae5aa4d2386","88110183-ea50-46f5-b469-809c1418a16d"],"dc:rights":["Copyright is reserved by the copyright owner","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["MARG III sensor","Control interface unit (CIU)","One-","Three-","Sixteen-Channel CIU","Avatar","Virtual environment","Virtual training","Immersion","Honeywell","Analog devices","Texas Instruments","Microcontoller","Micromachined sensor","X3D","Java","Xilinx","RS232","Wireless communication","WISER 2400"],"dc:title":["Design and implementation of a DSP-based control interface unit (CIU)"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant Junior Grade, Hellenic Navy"],"local:etd.verified":["no"],"thesis:degree_discipline":["Electrical Engineering","Systems Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Electrical Engineering","M.S. in Systems Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:06:04Z"}