{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/17451"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/17451","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Stability Analysis of a Constant Power Load Serviced by a Buck Converter as the Source Impedance Varies","abstract":"As the NAVY moves forward with plans to become less dependent on fossil fuels and more dependent on hybrid electric drives and all-electric ships, being aware of the stability issues associated with direct current (DC)-DC and DC-alternating current (AC) power converters and understanding how to solve the issues that come with using them, are very important. The negative input impedance that is observed when using a buck converter servicing a constant power load (CPL) is one of the issues that needs to be understood. Understanding the stability issue caused by the negative input impedance and mitigating this instability by varying the input source impedance is the focus of this thesis. Using a Simulink model of an ideal CPL, we determined the expected results. Then, the Simulink results were compared to the analysis of the linearized small signal transfer function to determine how well the results of the two matched. Finally, the hardware model was observed and its results compared to the Simulink model and linearized small signal transfer function. These experiments led to the conclusion that increasing the capacitance or decreasing the inductance reduces the input source impedance and, ultimately, reduces instability in the system.","abstract_html":"As the NAVY moves forward with plans to become less dependent on fossil fuels and more dependent on hybrid electric drives and all-electric ships, being aware of the stability issues associated with direct current (DC)-DC and DC-alternating current (AC) power converters and understanding how to solve the issues that come with using them, are very important. The negative input impedance that is observed when using a buck converter servicing a constant power load (CPL) is one of the issues that needs to be understood. Understanding the stability issue caused by the negative input impedance and mitigating this instability by varying the input source impedance is the focus of this thesis. Using a Simulink model of an ideal CPL, we determined the expected results. Then, the Simulink results were compared to the analysis of the linearized small signal transfer function to determine how well the results of the two matched. Finally, the hardware model was observed and its results compared to the Simulink model and linearized small signal transfer function. These experiments led to the conclusion that increasing the capacitance or decreasing the inductance reduces the input source impedance and, ultimately, reduces instability in the system.","abstract_has_math":false,"creators":["Roth, George J"],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"Master of Science In Electrical Engineering","degree_level":"Masters","degree_discipline":"Electrical Engineering","degree_department":"Electrical Engineering","school":null,"contributors":[],"advisors":["Julian, Alexander L."],"committee_chairs":[],"committee_members":["Oriti, Giovanna"],"year":2012,"date_issued":"2012-09","date_published":"2012-09","updated_at":"2026-11-19T06:06:58Z","subjects":[],"languages":[],"rights":["Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/17451","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/17451","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F17451","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F17451","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Julian, Alexander L."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Oriti, Giovanna"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical Engineering"]},{"key":"dc:creator","label":"Author","values":["Roth, George J"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-14T00:03:01Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-14T00:03:01Z"]},{"key":"dc:date.issued","label":"Date","values":["2012-09"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science In Electrical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Constant Power Load","Buck Converter","DCDC","Negative Impedance","Stability"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/17451"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["As the NAVY moves forward with plans to become less dependent on fossil fuels and more dependent on hybrid electric drives and all-electric ships, being aware of the stability issues associated with direct current (DC)-DC and DC-alternating current (AC) power converters and understanding how to solve the issues that come with using them, are very important. The negative input impedance that is observed when using a buck converter servicing a constant power load (CPL) is one of the issues that needs to be understood. Understanding the stability issue caused by the negative input impedance and mitigating this instability by varying the input source impedance is the focus of this thesis. Using a Simulink model of an ideal CPL, we determined the expected results. Then, the Simulink results were compared to the analysis of the linearized small signal transfer function to determine how well the results of the two matched. Finally, the hardware model was observed and its results compared to the Simulink model and linearized small signal transfer function. These experiments led to the conclusion that increasing the capacitance or decreasing the inductance reduces the input source impedance and, ultimately, reduces instability in the system."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/stabilityanalysi1094517451"]},{"key":"dc:title","label":"Title","values":["Stability Analysis of a Constant Power Load Serviced by a Buck Converter as the Source Impedance Varies"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Julian, Alexander L."],"dc:contributor.committeemember":["Oriti, Giovanna"],"dc:contributor.department":["Electrical Engineering"],"dc:creator":["Roth, George J"],"dc:date.accessioned":["2012-11-14T00:03:01Z"],"dc:date.available":["2012-11-14T00:03:01Z"],"dc:date.issued":["2012-09"],"dc:description.abstract":["As the NAVY moves forward with plans to become less dependent on fossil fuels and more dependent on hybrid electric drives and all-electric ships, being aware of the stability issues associated with direct current (DC)-DC and DC-alternating current (AC) power converters and understanding how to solve the issues that come with using them, are very important. The negative input impedance that is observed when using a buck converter servicing a constant power load (CPL) is one of the issues that needs to be understood. Understanding the stability issue caused by the negative input impedance and mitigating this instability by varying the input source impedance is the focus of this thesis. Using a Simulink model of an ideal CPL, we determined the expected results. Then, the Simulink results were compared to the analysis of the linearized small signal transfer function to determine how well the results of the two matched. Finally, the hardware model was observed and its results compared to the Simulink model and linearized small signal transfer function. These experiments led to the conclusion that increasing the capacitance or decreasing the inductance reduces the input source impedance and, ultimately, reduces instability in the system."],"dc:description.uri":["http://archive.org/details/stabilityanalysi1094517451"],"dc:identifier.uri":["https://hdl.handle.net/10945/17451"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Constant Power Load","Buck Converter","DCDC","Negative Impedance","Stability"],"dc:title":["Stability Analysis of a Constant Power Load Serviced by a Buck Converter as the Source Impedance Varies"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science In Electrical Engineering"]},"updated_at":"2026-11-19T06:06:58Z"}