{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/18128"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/18128","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"A feasibility study of heat transfer improvement in marine stream condensers.","abstract":"A survey of condenser design principles and heat transfer augmentation schemes is provided. Using the ORCON 1 computer code, as developed by Oak Ridge National Laboratory, a thermal analysis was performed on the main condenser of the USS John F. Kennedy, CVA-67. A comparison was made between the standard design and fifteen test cases where heat transfer was improved using a variety of techniques, including internally finned tubing, corrugated tubing, promotion of dropwise condensation, and use of thin-walled titanium tubing at high sea water velocities. Each case was compared for heat load capability at constant pumping power, and for weight, volume, and estimated cost at an equivalent heat load. Results show that with the present condenser volume, the heat load can be increased by as much as 50 percent using heat transfer improvement techniques. From a different point of view, at the same heat load, a 40 percent reduction in condenser weight and volume may be feasible. Several of the proposed heat transfer improvement schemes may lead, however, to increased pumping power and/or cost. Continued research is recommended in several promising areas to provide more adequate design information and to improve the long term reliability of these proposed schemes.","abstract_html":"A survey of condenser design principles and heat transfer augmentation schemes is provided. Using the ORCON 1 computer code, as developed by Oak Ridge National Laboratory, a thermal analysis was performed on the main condenser of the USS John F. Kennedy, CVA-67. A comparison was made between the standard design and fifteen test cases where heat transfer was improved using a variety of techniques, including internally finned tubing, corrugated tubing, promotion of dropwise condensation, and use of thin-walled titanium tubing at high sea water velocities. Each case was compared for heat load capability at constant pumping power, and for weight, volume, and estimated cost at an equivalent heat load. Results show that with the present condenser volume, the heat load can be increased by as much as 50 percent using heat transfer improvement techniques. From a different point of view, at the same heat load, a 40 percent reduction in condenser weight and volume may be feasible. Several of the proposed heat transfer improvement schemes may lead, however, to increased pumping power and/or cost. Continued research is recommended in several promising areas to provide more adequate design information and to improve the long term reliability of these proposed schemes.","abstract_has_math":false,"creators":["Search, Harry Thomas"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering (ME)","school":null,"contributors":[],"advisors":["Marto, Paul J."],"committee_chairs":[],"committee_members":[],"year":1977,"date_issued":"1977-12","date_published":"1977-12","updated_at":"2026-11-20T22:16:43Z","subjects":["Mechanical engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["ocn640235515"],"render_values":[{"text":"ocn640235515","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["NPS69-77-001"],"render_values":[{"text":"NPS69-77-001","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/18128","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/18128","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F18128","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F18128","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Marto, Paul J."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering (ME)"]},{"key":"dc:creator","label":"Author","values":["Search, Harry Thomas"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-16T19:14:58Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-16T19:14:58Z"]},{"key":"dc:date.issued","label":"Date","values":["1977-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["be4a5ea6-677a-43c8-bd87-7e223a840335"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["condenser","film condensation","heat transfer augmentation"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Mechanical engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["ocn640235515"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["NPS69-77-001"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/18128"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Prepared for: Naval Sea Systems Command Washington, D.C."]},{"key":"dc:description.abstract","label":"Abstract","values":["A survey of condenser design principles and heat transfer augmentation schemes is provided. Using the ORCON 1 computer code, as developed by Oak Ridge National Laboratory, a thermal analysis was performed on the main condenser of the USS John F. Kennedy, CVA-67. A comparison was made between the standard design and fifteen test cases where heat transfer was improved using a variety of techniques, including internally finned tubing, corrugated tubing, promotion of dropwise condensation, and use of thin-walled titanium tubing at high sea water velocities. Each case was compared for heat load capability at constant pumping power, and for weight, volume, and estimated cost at an equivalent heat load. Results show that with the present condenser volume, the heat load can be increased by as much as 50 percent using heat transfer improvement techniques. From a different point of view, at the same heat load, a 40 percent reduction in condenser weight and volume may be feasible. Several of the proposed heat transfer improvement schemes may lead, however, to increased pumping power and/or cost. Continued research is recommended in several promising areas to provide more adequate design information and to improve the long term reliability of these proposed schemes."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/afeasibilitystud1094518128"]},{"key":"dc:title","label":"Title","values":["A feasibility study of heat transfer improvement in marine stream condensers."]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Marto, Paul J."],"dc:contributor.department":["Mechanical Engineering (ME)"],"dc:creator":["Search, Harry Thomas"],"dc:date.accessioned":["2012-11-16T19:14:58Z"],"dc:date.available":["2012-11-16T19:14:58Z"],"dc:date.issued":["1977-12"],"dc:description":["Prepared for: Naval Sea Systems Command Washington, D.C."],"dc:description.abstract":["A survey of condenser design principles and heat transfer augmentation schemes is provided. Using the ORCON 1 computer code, as developed by Oak Ridge National Laboratory, a thermal analysis was performed on the main condenser of the USS John F. Kennedy, CVA-67. A comparison was made between the standard design and fifteen test cases where heat transfer was improved using a variety of techniques, including internally finned tubing, corrugated tubing, promotion of dropwise condensation, and use of thin-walled titanium tubing at high sea water velocities. Each case was compared for heat load capability at constant pumping power, and for weight, volume, and estimated cost at an equivalent heat load. Results show that with the present condenser volume, the heat load can be increased by as much as 50 percent using heat transfer improvement techniques. From a different point of view, at the same heat load, a 40 percent reduction in condenser weight and volume may be feasible. Several of the proposed heat transfer improvement schemes may lead, however, to increased pumping power and/or cost. Continued research is recommended in several promising areas to provide more adequate design information and to improve the long term reliability of these proposed schemes."],"dc:description.uri":["http://archive.org/details/afeasibilitystud1094518128"],"dc:identifier.oclc":["ocn640235515"],"dc:identifier.other":["NPS69-77-001"],"dc:identifier.uri":["https://hdl.handle.net/10945/18128"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.orgunit":["be4a5ea6-677a-43c8-bd87-7e223a840335"],"dc:subject.keyword":["condenser","film condensation","heat transfer augmentation"],"dc:subject.lcsh":["Mechanical engineering"],"dc:title":["A feasibility study of heat transfer improvement in marine stream condensers."],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-20T22:16:43Z"}