{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/18139"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/18139","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Gravitational effects on the operation of a variable conductance heat pipe.","abstract":"A variable conductance heat pipe, measuring 2.5 centimeters in diameter and 152 centimeters in length, was built. The heat pipe was operated in both the conventional and variable conductance modes to obtain experimental data concerning performance characteristics. The input electrical power was varied from 20 to 50 watts with the heat pipe placed in both the horizontal and vertical positions. Methanol and Freon 113 were selected as the working fluids; helium and krypton were the non-condensible gases. In the variable conductance mode, liquid crystals were used to observe qualitatively the temperature gradients occurring across the vapor-gas interface. Summarized performance data for the various operating conditions and graphs of the isotherms obtained from the liquid crystal data are presented.","abstract_html":"A variable conductance heat pipe, measuring 2.5 centimeters in diameter and 152 centimeters in length, was built. The heat pipe was operated in both the conventional and variable conductance modes to obtain experimental data concerning performance characteristics. The input electrical power was varied from 20 to 50 watts with the heat pipe placed in both the horizontal and vertical positions. Methanol and Freon 113 were selected as the working fluids; helium and krypton were the non-condensible gases. In the variable conductance mode, liquid crystals were used to observe qualitatively the temperature gradients occurring across the vapor-gas interface. Summarized performance data for the various operating conditions and graphs of the isotherms obtained from the liquid crystal data are presented.","abstract_has_math":false,"creators":["Owendoff, Robert Scott"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering (ME)","school":null,"contributors":[],"advisors":["Kelleher, M.D."],"committee_chairs":[],"committee_members":[],"year":1977,"date_issued":"1977-03","date_published":"1977-03","updated_at":"2026-11-21T22:50:11Z","subjects":["Mechanical engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["ocn640248067"],"render_values":[{"text":"ocn640248067","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/18139","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/18139","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F18139","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F18139","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Kelleher, M.D."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering (ME)"]},{"key":"dc:creator","label":"Author","values":["Owendoff, Robert Scott"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-16T19:15:09Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-16T19:15:09Z"]},{"key":"dc:date.issued","label":"Date","values":["1977-03"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["be4a5ea6-677a-43c8-bd87-7e223a840335"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["heat pipe","heat transfer device","gas loaded heat pipe","variable conductance heat pipe"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Mechanical engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["ocn640248067"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/18139"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A variable conductance heat pipe, measuring 2.5 centimeters in diameter and 152 centimeters in length, was built. The heat pipe was operated in both the conventional and variable conductance modes to obtain experimental data concerning performance characteristics. The input electrical power was varied from 20 to 50 watts with the heat pipe placed in both the horizontal and vertical positions. Methanol and Freon 113 were selected as the working fluids; helium and krypton were the non-condensible gases. In the variable conductance mode, liquid crystals were used to observe qualitatively the temperature gradients occurring across the vapor-gas interface. Summarized performance data for the various operating conditions and graphs of the isotherms obtained from the liquid crystal data are presented."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/gravitationaleff1094518139"]},{"key":"dc:title","label":"Title","values":["Gravitational effects on the operation of a variable conductance heat pipe."]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Kelleher, M.D."],"dc:contributor.department":["Mechanical Engineering (ME)"],"dc:creator":["Owendoff, Robert Scott"],"dc:date.accessioned":["2012-11-16T19:15:09Z"],"dc:date.available":["2012-11-16T19:15:09Z"],"dc:date.issued":["1977-03"],"dc:description.abstract":["A variable conductance heat pipe, measuring 2.5 centimeters in diameter and 152 centimeters in length, was built. The heat pipe was operated in both the conventional and variable conductance modes to obtain experimental data concerning performance characteristics. The input electrical power was varied from 20 to 50 watts with the heat pipe placed in both the horizontal and vertical positions. Methanol and Freon 113 were selected as the working fluids; helium and krypton were the non-condensible gases. In the variable conductance mode, liquid crystals were used to observe qualitatively the temperature gradients occurring across the vapor-gas interface. Summarized performance data for the various operating conditions and graphs of the isotherms obtained from the liquid crystal data are presented."],"dc:description.uri":["http://archive.org/details/gravitationaleff1094518139"],"dc:identifier.oclc":["ocn640248067"],"dc:identifier.uri":["https://hdl.handle.net/10945/18139"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.orgunit":["be4a5ea6-677a-43c8-bd87-7e223a840335"],"dc:subject.keyword":["heat pipe","heat transfer device","gas loaded heat pipe","variable conductance heat pipe"],"dc:subject.lcsh":["Mechanical engineering"],"dc:title":["Gravitational effects on the operation of a variable conductance heat pipe."],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T22:50:11Z"}