{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/18237"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/18237","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Physiological correlates of vigilance performance","abstract":"This research is an investigation of the relationships between several physiological measures and vigilance performance. Heart rate and sinus arrhythmia were measured throughout a 40-minute vigilance task for each of 15 subjects. Information processing rate, depth perception and critical flicker fusion frequency were measured before and after the task. Significant results were found by linear correlation techniques which showed pre-test depth perception and detection performance negatively correlated (r = .585, p < .05), pre-test critical flicker fusion frequency and detection performance positively correrlated r = .492, p < .05), and heart rate positively correlated with detection performance (r = .7703, p < .1).","abstract_html":"This research is an investigation of the relationships between several physiological measures and vigilance performance. Heart rate and sinus arrhythmia were measured throughout a 40-minute vigilance task for each of 15 subjects. Information processing rate, depth perception and critical flicker fusion frequency were measured before and after the task. Significant results were found by linear correlation techniques which showed pre-test depth perception and detection performance negatively correlated (r = .585, p &lt; .05), pre-test critical flicker fusion frequency and detection performance positively correrlated r = .492, p &lt; .05), and heart rate positively correlated with detection performance (r = .7703, p &lt; .1).","abstract_has_math":false,"creators":["Coons, William Eric"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S. in Operations Research","degree_level":"Masters","degree_discipline":"Operations Research","degree_department":"Department of Operations Research","school":null,"contributors":[],"advisors":["Poock, Gary K."],"committee_chairs":[],"committee_members":["Neil, Douglas E."],"year":1977,"date_issued":"1977-03","date_published":"1977-03","updated_at":"2026-11-26T00:15:05Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/18237","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/18237","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F18237","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F18237","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Poock, Gary K."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Neil, Douglas E."]},{"key":"dc:contributor.department","label":"Department","values":["Department of Operations Research"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Coons, William Eric"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["March 1977"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-16T19:16:25Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-16T19:16:25Z"]},{"key":"dc:date.issued","label":"Date","values":["1977-03"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Operations Research"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Operations Research"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Vigilance","Monitoring","Sinus arrythmia","Heart rate","Depth perception","Critical flicker fusion frequency","Information processing rate","Detection performance","Physiological parameters"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/18237"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This research is an investigation of the relationships between several physiological measures and vigilance performance. Heart rate and sinus arrhythmia were measured throughout a 40-minute vigilance task for each of 15 subjects. Information processing rate, depth perception and critical flicker fusion frequency were measured before and after the task. Significant results were found by linear correlation techniques which showed pre-test depth perception and detection performance negatively correlated (r = .585, p < .05), pre-test critical flicker fusion frequency and detection performance positively correrlated r = .492, p < .05), and heart rate positively correlated with detection performance (r = .7703, p < .1)."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/physiologicalcor1094518237"]},{"key":"dc:title","label":"Title","values":["Physiological correlates of vigilance performance"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Poock, Gary K."],"dc:contributor.committeemember":["Neil, Douglas E."],"dc:contributor.department":["Department of Operations Research"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Coons, William Eric"],"dc:date":["March 1977"],"dc:date.accessioned":["2012-11-16T19:16:25Z"],"dc:date.available":["2012-11-16T19:16:25Z"],"dc:date.issued":["1977-03"],"dc:description.abstract":["This research is an investigation of the relationships between several physiological measures and vigilance performance. Heart rate and sinus arrhythmia were measured throughout a 40-minute vigilance task for each of 15 subjects. Information processing rate, depth perception and critical flicker fusion frequency were measured before and after the task. Significant results were found by linear correlation techniques which showed pre-test depth perception and detection performance negatively correlated (r = .585, p < .05), pre-test critical flicker fusion frequency and detection performance positively correrlated r = .492, p < .05), and heart rate positively correlated with detection performance (r = .7703, p < .1)."],"dc:description.uri":["http://archive.org/details/physiologicalcor1094518237"],"dc:identifier.uri":["https://hdl.handle.net/10945/18237"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Vigilance","Monitoring","Sinus arrythmia","Heart rate","Depth perception","Critical flicker fusion frequency","Information processing rate","Detection performance","Physiological parameters"],"dc:title":["Physiological correlates of vigilance performance"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Operations Research"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Operations Research"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-26T00:15:05Z"}