{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/18282"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/18282","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Some experimental observations of dropwise condensation of steam.","abstract":"Using a tiltable steam condenser test section, the parametric effects of heat flux, non-condensable gas, promoter, condenser surface thermal resistance, and surface inclination were studied on a 3.18 mm thick flat copper plate and on 0.051 mm thick foils of copper and titanium. Any non-condensable gas concentration, however small, reduces the heat transfer coefficient significantly during dropwise condensation. Non-condensable gases also cause large surface temperature fluctuations, resulting in difficulties of accurately measuring heat transfer coefficients. The recorded data for the heat transfer coefficient of this experiment is lower than previous investigations, possibly due to a concentration of non-condensable gases which resulted from the low steam velocity past the condenser surface or due to the effects of the thin condenser surfaces used. With a vertical, copper surface, the heat transfer coefficient increases by a factor of five when the condenser surface thickness increases from 0.051 mm to 3.18 mm. The heat transfer coefficient is higher for dropwise condensation on copper than for titanium with mixed condensation. Surface inclination from the vertical position decreases the heat transfer coefficient by as much as 50 percent.","abstract_html":"Using a tiltable steam condenser test section, the parametric effects of heat flux, non-condensable gas, promoter, condenser surface thermal resistance, and surface inclination were studied on a 3.18 mm thick flat copper plate and on 0.051 mm thick foils of copper and titanium. Any non-condensable gas concentration, however small, reduces the heat transfer coefficient significantly during dropwise condensation. Non-condensable gases also cause large surface temperature fluctuations, resulting in difficulties of accurately measuring heat transfer coefficients. The recorded data for the heat transfer coefficient of this experiment is lower than previous investigations, possibly due to a concentration of non-condensable gases which resulted from the low steam velocity past the condenser surface or due to the effects of the thin condenser surfaces used. With a vertical, copper surface, the heat transfer coefficient increases by a factor of five when the condenser surface thickness increases from 0.051 mm to 3.18 mm. The heat transfer coefficient is higher for dropwise condensation on copper than for titanium with mixed condensation. Surface inclination from the vertical position decreases the heat transfer coefficient by as much as 50 percent.","abstract_has_math":false,"creators":["Morgan, James Larry"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering (ME)","school":null,"contributors":[],"advisors":["Marto, P.J."],"committee_chairs":[],"committee_members":[],"year":1977,"date_issued":"1977-03","date_published":"1977-03","updated_at":"2026-11-21T22:38:38Z","subjects":["Mechanical engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["ocm640229488"],"render_values":[{"text":"ocm640229488","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/18282","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/18282","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F18282","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F18282","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Marto, P.J."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering (ME)"]},{"key":"dc:creator","label":"Author","values":["Morgan, James Larry"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-16T19:16:48Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-16T19:16:48Z"]},{"key":"dc:date.issued","label":"Date","values":["1977-03"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["be4a5ea6-677a-43c8-bd87-7e223a840335"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["dropwise condensation"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Mechanical engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["ocm640229488"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/18282"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Using a tiltable steam condenser test section, the parametric effects of heat flux, non-condensable gas, promoter, condenser surface thermal resistance, and surface inclination were studied on a 3.18 mm thick flat copper plate and on 0.051 mm thick foils of copper and titanium. Any non-condensable gas concentration, however small, reduces the heat transfer coefficient significantly during dropwise condensation. Non-condensable gases also cause large surface temperature fluctuations, resulting in difficulties of accurately measuring heat transfer coefficients. The recorded data for the heat transfer coefficient of this experiment is lower than previous investigations, possibly due to a concentration of non-condensable gases which resulted from the low steam velocity past the condenser surface or due to the effects of the thin condenser surfaces used. With a vertical, copper surface, the heat transfer coefficient increases by a factor of five when the condenser surface thickness increases from 0.051 mm to 3.18 mm. The heat transfer coefficient is higher for dropwise condensation on copper than for titanium with mixed condensation. Surface inclination from the vertical position decreases the heat transfer coefficient by as much as 50 percent."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/someexperimental1094518282"]},{"key":"dc:title","label":"Title","values":["Some experimental observations of dropwise condensation of steam."]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Marto, P.J."],"dc:contributor.department":["Mechanical Engineering (ME)"],"dc:creator":["Morgan, James Larry"],"dc:date.accessioned":["2012-11-16T19:16:48Z"],"dc:date.available":["2012-11-16T19:16:48Z"],"dc:date.issued":["1977-03"],"dc:description.abstract":["Using a tiltable steam condenser test section, the parametric effects of heat flux, non-condensable gas, promoter, condenser surface thermal resistance, and surface inclination were studied on a 3.18 mm thick flat copper plate and on 0.051 mm thick foils of copper and titanium. Any non-condensable gas concentration, however small, reduces the heat transfer coefficient significantly during dropwise condensation. Non-condensable gases also cause large surface temperature fluctuations, resulting in difficulties of accurately measuring heat transfer coefficients. The recorded data for the heat transfer coefficient of this experiment is lower than previous investigations, possibly due to a concentration of non-condensable gases which resulted from the low steam velocity past the condenser surface or due to the effects of the thin condenser surfaces used. With a vertical, copper surface, the heat transfer coefficient increases by a factor of five when the condenser surface thickness increases from 0.051 mm to 3.18 mm. The heat transfer coefficient is higher for dropwise condensation on copper than for titanium with mixed condensation. Surface inclination from the vertical position decreases the heat transfer coefficient by as much as 50 percent."],"dc:description.uri":["http://archive.org/details/someexperimental1094518282"],"dc:identifier.oclc":["ocm640229488"],"dc:identifier.uri":["https://hdl.handle.net/10945/18282"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.orgunit":["be4a5ea6-677a-43c8-bd87-7e223a840335"],"dc:subject.keyword":["dropwise condensation"],"dc:subject.lcsh":["Mechanical engineering"],"dc:title":["Some experimental observations of dropwise condensation of steam."],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T22:38:38Z"}