{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/18352"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/18352","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"An apparatus to measure dropwise condensation heat transfer coefficients of steam","abstract":"An experimental apparatus was designed and constructed for the purpose of determining dropwise condensation heat transfer coefficients on condensing surfaces of different thickness. The equipment included a completely self contained condensing chamber which enclosed both the boiler and condensing surface. Variable temperature cooling water was utilized to control the heat flux. A thin film resistance thermometer was constructed to obtain the average surface temperature of the condensing surface. Inability to obtain linear and repeatable calibration data with this thermometer resulted in its being discarded. An intrinsic thermocouple was used in lieu of of the thin film resistance thermometer.","abstract_html":"An experimental apparatus was designed and constructed for the purpose of determining dropwise condensation heat transfer coefficients on condensing surfaces of different thickness. The equipment included a completely self contained condensing chamber which enclosed both the boiler and condensing surface. Variable temperature cooling water was utilized to control the heat flux. A thin film resistance thermometer was constructed to obtain the average surface temperature of the condensing surface. Inability to obtain linear and repeatable calibration data with this thermometer resulted in its being discarded. An intrinsic thermocouple was used in lieu of of the thin film resistance thermometer.","abstract_has_math":false,"creators":["Sharp, Larry Ralph"],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Marto, P.J."],"committee_chairs":[],"committee_members":[],"year":1978,"date_issued":"1978-03","date_published":"1978-03","updated_at":"2026-11-21T23:28:52Z","subjects":["Mechanical engineering"],"languages":[],"rights":["Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/18352","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/18352","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F18352","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Marto, P.J."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Sharp, Larry Ralph"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-16T19:21:01Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-16T19:21:01Z"]},{"key":"dc:date.issued","label":"Date","values":["1978-03"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Dropwise Condensation","Thin Film Resistance Thermometer","Thickness Dependence"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/18352"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An experimental apparatus was designed and constructed for the purpose of determining dropwise condensation heat transfer coefficients on condensing surfaces of different thickness. The equipment included a completely self contained condensing chamber which enclosed both the boiler and condensing surface. Variable temperature cooling water was utilized to control the heat flux. A thin film resistance thermometer was constructed to obtain the average surface temperature of the condensing surface. Inability to obtain linear and repeatable calibration data with this thermometer resulted in its being discarded. An intrinsic thermocouple was used in lieu of of the thin film resistance thermometer."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/anpparatustomeas1094518352"]},{"key":"dc:title","label":"Title","values":["An apparatus to measure dropwise condensation heat transfer coefficients of steam"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Marto, P.J."],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Sharp, Larry Ralph"],"dc:date.accessioned":["2012-11-16T19:21:01Z"],"dc:date.available":["2012-11-16T19:21:01Z"],"dc:date.issued":["1978-03"],"dc:description.abstract":["An experimental apparatus was designed and constructed for the purpose of determining dropwise condensation heat transfer coefficients on condensing surfaces of different thickness. The equipment included a completely self contained condensing chamber which enclosed both the boiler and condensing surface. Variable temperature cooling water was utilized to control the heat flux. A thin film resistance thermometer was constructed to obtain the average surface temperature of the condensing surface. Inability to obtain linear and repeatable calibration data with this thermometer resulted in its being discarded. An intrinsic thermocouple was used in lieu of of the thin film resistance thermometer."],"dc:description.uri":["http://archive.org/details/anpparatustomeas1094518352"],"dc:identifier.uri":["https://hdl.handle.net/10945/18352"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Dropwise Condensation","Thin Film Resistance Thermometer","Thickness Dependence"],"dc:subject.lcsh":["Mechanical engineering"],"dc:title":["An apparatus to measure dropwise condensation heat transfer coefficients of steam"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T23:28:52Z"}