{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/18720"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/18720","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"An experimental study of filmwise condensation on horizontal enhanced condenser tubing","abstract":"Heat transfer and hydrodynamic performance of eight different geometrically enhanced tubes of different metals was determined. Results were compared to a 25.4 mm (1.0 inch) OD, smooth stainless steel tube. Steam at about 21 kPa (3 psia) was condensed on the outside surface of each enhanced tube, horizontally mounted in the center of a dummy tube bank. Each tube was cooled on the inside by water. The overall heat transfer coefficient was determined directly from experimental data. The inside and outside heat transfer coefficients were determined using the Wilson plot technique. The cooling water pressure drop was measured inside the tube and converted to the friction factor in the enhanced section. The overall heat transfer coefficients of the enhanced tubes were increased as much as 1.9 times, and the corrected pressure drops of the enhanced tubes were as large as 4 times the corresponding smooth tube value for the same cooling water velocity.","abstract_html":"Heat transfer and hydrodynamic performance of eight different geometrically enhanced tubes of different metals was determined. Results were compared to a 25.4 mm (1.0 inch) OD, smooth stainless steel tube. Steam at about 21 kPa (3 psia) was condensed on the outside surface of each enhanced tube, horizontally mounted in the center of a dummy tube bank. Each tube was cooled on the inside by water. The overall heat transfer coefficient was determined directly from experimental data. The inside and outside heat transfer coefficients were determined using the Wilson plot technique. The cooling water pressure drop was measured inside the tube and converted to the friction factor in the enhanced section. The overall heat transfer coefficients of the enhanced tubes were increased as much as 1.9 times, and the corrected pressure drops of the enhanced tubes were as large as 4 times the corresponding smooth tube value for the same cooling water velocity.","abstract_has_math":false,"creators":["Ciftci, Huseyin"],"institution":"Monterey, California : Naval Postgraduate School","degree_name":"M.S. in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":"Naval Postgraduate School","contributors":[],"advisors":["Marto, P.J."],"committee_chairs":[],"committee_members":[],"year":1979,"date_issued":"1979","date_published":"1979","updated_at":"2026-11-21T22:41:42Z","subjects":["Mechanical engineering"],"languages":[],"rights":["Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["NPS-69-79-014"],"render_values":[{"text":"NPS-69-79-014","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/18720","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/18720","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F18720","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F18720","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Marto, P.J."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School"]},{"key":"dc:contributor.school","label":"School","values":["Naval Postgraduate School"]},{"key":"dc:creator","label":"Author","values":["Ciftci, Huseyin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-16T19:30:06Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-16T19:30:06Z"]},{"key":"dc:date.issued","label":"Date","values":["1979"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California : Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Filmwise Condensation","Augmented Heat Transfer","Condenser"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["NPS-69-79-014"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/18720"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Heat transfer and hydrodynamic performance of eight different geometrically enhanced tubes of different metals was determined. Results were compared to a 25.4 mm (1.0 inch) OD, smooth stainless steel tube. Steam at about 21 kPa (3 psia) was condensed on the outside surface of each enhanced tube, horizontally mounted in the center of a dummy tube bank. Each tube was cooled on the inside by water. The overall heat transfer coefficient was determined directly from experimental data. The inside and outside heat transfer coefficients were determined using the Wilson plot technique. The cooling water pressure drop was measured inside the tube and converted to the friction factor in the enhanced section. The overall heat transfer coefficients of the enhanced tubes were increased as much as 1.9 times, and the corrected pressure drops of the enhanced tubes were as large as 4 times the corresponding smooth tube value for the same cooling water velocity."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/anexperimentalst1094518720"]},{"key":"dc:title","label":"Title","values":["An experimental study of filmwise condensation on horizontal enhanced condenser tubing"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, Turkish Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Marto, P.J."],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["Naval Postgraduate School"],"dc:contributor.school":["Naval Postgraduate School"],"dc:creator":["Ciftci, Huseyin"],"dc:date.accessioned":["2012-11-16T19:30:06Z"],"dc:date.available":["2012-11-16T19:30:06Z"],"dc:date.issued":["1979"],"dc:description.abstract":["Heat transfer and hydrodynamic performance of eight different geometrically enhanced tubes of different metals was determined. Results were compared to a 25.4 mm (1.0 inch) OD, smooth stainless steel tube. Steam at about 21 kPa (3 psia) was condensed on the outside surface of each enhanced tube, horizontally mounted in the center of a dummy tube bank. Each tube was cooled on the inside by water. The overall heat transfer coefficient was determined directly from experimental data. The inside and outside heat transfer coefficients were determined using the Wilson plot technique. The cooling water pressure drop was measured inside the tube and converted to the friction factor in the enhanced section. The overall heat transfer coefficients of the enhanced tubes were increased as much as 1.9 times, and the corrected pressure drops of the enhanced tubes were as large as 4 times the corresponding smooth tube value for the same cooling water velocity."],"dc:description.uri":["http://archive.org/details/anexperimentalst1094518720"],"dc:identifier.other":["NPS-69-79-014"],"dc:identifier.uri":["https://hdl.handle.net/10945/18720"],"dc:publisher":["Monterey, California : Naval Postgraduate School"],"dc:rights":["Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Filmwise Condensation","Augmented Heat Transfer","Condenser"],"dc:subject.lcsh":["Mechanical engineering"],"dc:title":["An experimental study of filmwise condensation on horizontal enhanced condenser tubing"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, Turkish Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T22:41:42Z"}