{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/18721"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/18721","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"An experimental study of dropwise condensation on horizontal condenser tubes","abstract":"Three types of drop promoting coatings were applied to the outside of 15.9 mm (5/8 in) outside-diameter condenser tubes to determine their effect on heat transfer performance. The coatings included a new fluoroepoxy, a commercial series of fluorocarbon coatings, and sputtered TFE. Coating thickness varied from 0.0 2 to 12.7 microns. Steam at about 21 KPa (3 psia) was condensed on the outside surface of each coated tube, horizontally mounted in the center of a dummy tube bundle. Each test tube was cooled on the inside by water at velocities of 0.80 to 7.60 m/sec (3 to 25 ft/sec). The overall heat transfer coefficient was determined directly from experimental data. The inside and outside, heat transfer coefficients were determined by using the Wilson Plot technique. Of the commercial fluorocarbon coatings, the \"Nedox\" coating on a copper-nickel tube enhanced the outside heat transfer coefficient by 53% and improved the corrected overall heat transfer coefficient by 27%. Of the sputtered TFE coated tubes, the 0.08-micron thick coating on a copper-nickel tube enhanced the outside heat transfer coefficient by 45% and improved the corrected overall heat transfer coefficient by 21%. Evidence of the effect of the thermal conductivity of the condensing surface substrate, and evidence of an optimum coating thickness were found.","abstract_html":"Three types of drop promoting coatings were applied to the outside of 15.9 mm (5/8 in) outside-diameter condenser tubes to determine their effect on heat transfer performance. The coatings included a new fluoroepoxy, a commercial series of fluorocarbon coatings, and sputtered TFE. Coating thickness varied from 0.0 2 to 12.7 microns. Steam at about 21 KPa (3 psia) was condensed on the outside surface of each coated tube, horizontally mounted in the center of a dummy tube bundle. Each test tube was cooled on the inside by water at velocities of 0.80 to 7.60 m/sec (3 to 25 ft/sec). The overall heat transfer coefficient was determined directly from experimental data. The inside and outside, heat transfer coefficients were determined by using the Wilson Plot technique. Of the commercial fluorocarbon coatings, the &quot;Nedox&quot; coating on a copper-nickel tube enhanced the outside heat transfer coefficient by 53% and improved the corrected overall heat transfer coefficient by 27%. Of the sputtered TFE coated tubes, the 0.08-micron thick coating on a copper-nickel tube enhanced the outside heat transfer coefficient by 45% and improved the corrected overall heat transfer coefficient by 21%. Evidence of the effect of the thermal conductivity of the condensing surface substrate, and evidence of an optimum coating thickness were found.","abstract_has_math":false,"creators":["Manvel, John Talbot Jr."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S. in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Marto, P.J."],"committee_chairs":[],"committee_members":[],"year":1979,"date_issued":"1979-06","date_published":"1979-06","updated_at":"2026-11-26T00:11:43Z","subjects":["Mechanical engineering"],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["NPS 69-79-004"],"render_values":[{"text":"NPS 69-79-004","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/18721","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/18721","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F18721","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F18721","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Marto, P.J."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Manvel, John Talbot Jr."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["June 1979"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-16T19:30:07Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-16T19:30:07Z"]},{"key":"dc:date.issued","label":"Date","values":["1979-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["dropwise condensation","enhanced heat transfer","condensers","promoters","coatings"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["NPS 69-79-004"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/18721"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Three types of drop promoting coatings were applied to the outside of 15.9 mm (5/8 in) outside-diameter condenser tubes to determine their effect on heat transfer performance. The coatings included a new fluoroepoxy, a commercial series of fluorocarbon coatings, and sputtered TFE. Coating thickness varied from 0.0 2 to 12.7 microns. Steam at about 21 KPa (3 psia) was condensed on the outside surface of each coated tube, horizontally mounted in the center of a dummy tube bundle. Each test tube was cooled on the inside by water at velocities of 0.80 to 7.60 m/sec (3 to 25 ft/sec). The overall heat transfer coefficient was determined directly from experimental data. The inside and outside, heat transfer coefficients were determined by using the Wilson Plot technique. Of the commercial fluorocarbon coatings, the \"Nedox\" coating on a copper-nickel tube enhanced the outside heat transfer coefficient by 53% and improved the corrected overall heat transfer coefficient by 27%. Of the sputtered TFE coated tubes, the 0.08-micron thick coating on a copper-nickel tube enhanced the outside heat transfer coefficient by 45% and improved the corrected overall heat transfer coefficient by 21%. Evidence of the effect of the thermal conductivity of the condensing surface substrate, and evidence of an optimum coating thickness were found."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Naval Sea Systems Command, work request N0002479-WR9G078"]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/anexperimentalst1094518721"]},{"key":"dc:title","label":"Title","values":["An experimental study of dropwise condensation on horizontal condenser tubes"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Marto, P.J."],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Manvel, John Talbot Jr."],"dc:date":["June 1979"],"dc:date.accessioned":["2012-11-16T19:30:07Z"],"dc:date.available":["2012-11-16T19:30:07Z"],"dc:date.issued":["1979-06"],"dc:description.abstract":["Three types of drop promoting coatings were applied to the outside of 15.9 mm (5/8 in) outside-diameter condenser tubes to determine their effect on heat transfer performance. The coatings included a new fluoroepoxy, a commercial series of fluorocarbon coatings, and sputtered TFE. Coating thickness varied from 0.0 2 to 12.7 microns. Steam at about 21 KPa (3 psia) was condensed on the outside surface of each coated tube, horizontally mounted in the center of a dummy tube bundle. Each test tube was cooled on the inside by water at velocities of 0.80 to 7.60 m/sec (3 to 25 ft/sec). The overall heat transfer coefficient was determined directly from experimental data. The inside and outside, heat transfer coefficients were determined by using the Wilson Plot technique. Of the commercial fluorocarbon coatings, the \"Nedox\" coating on a copper-nickel tube enhanced the outside heat transfer coefficient by 53% and improved the corrected overall heat transfer coefficient by 27%. Of the sputtered TFE coated tubes, the 0.08-micron thick coating on a copper-nickel tube enhanced the outside heat transfer coefficient by 45% and improved the corrected overall heat transfer coefficient by 21%. Evidence of the effect of the thermal conductivity of the condensing surface substrate, and evidence of an optimum coating thickness were found."],"dc:description.sponsorship":["Naval Sea Systems Command, work request N0002479-WR9G078"],"dc:description.uri":["http://archive.org/details/anexperimentalst1094518721"],"dc:identifier.other":["NPS 69-79-004"],"dc:identifier.uri":["https://hdl.handle.net/10945/18721"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["dropwise condensation","enhanced heat transfer","condensers","promoters","coatings"],"dc:subject.lcsh":["Mechanical engineering"],"dc:title":["An experimental study of dropwise condensation on horizontal condenser tubes"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-26T00:11:43Z"}