{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/19062"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/19062","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Stark cell stabilization of a CO(2) laser","abstract":"Studies have been conducted of the frequency stabilization of the output from a Sylvania 941 Carbon Dioxide laser by active comparison with a Stark-tuned NH(2)D line center in an absorption cell. A dithered Stark voltage gave a peak-detection correction signal fed back to a PZT mounted laser resonator mirror to control the cavity optical length. Operation of an integrator incorporated in the feedback loop to improve the system stability has been investigated. A method was demonstrated of using the integrator to locate the desired laser vibronic transition by scanning the laser through its spectral signature prior to initiation of servo operation. An unexpected discontinuity in the absorption lineshape of a Stark-tunable cell was discovered which made the cell unsuitable for generation of the feedback signal. A new and more versatile Stark cell was designed for test and evaluation of cell plate configuration and fabrication.","abstract_html":"Studies have been conducted of the frequency stabilization of the output from a Sylvania 941 Carbon Dioxide laser by active comparison with a Stark-tuned NH(2)D line center in an absorption cell. A dithered Stark voltage gave a peak-detection correction signal fed back to a PZT mounted laser resonator mirror to control the cavity optical length. Operation of an integrator incorporated in the feedback loop to improve the system stability has been investigated. A method was demonstrated of using the integrator to locate the desired laser vibronic transition by scanning the laser through its spectral signature prior to initiation of servo operation. An unexpected discontinuity in the absorption lineshape of a Stark-tunable cell was discovered which made the cell unsuitable for generation of the feedback signal. A new and more versatile Stark cell was designed for test and evaluation of cell plate configuration and fabrication.","abstract_has_math":false,"creators":["Knolhoff, Larry Edward"],"institution":"Monterey, California; Naval Postgraduate School","degree_name":"M.S. in Physics","degree_level":"Masters","degree_discipline":"Physics","degree_department":"Department of Physics and Chemistry","school":null,"contributors":[],"advisors":["Cooper, A.W."],"committee_chairs":[],"committee_members":["Crittenden, E. C., Jr."],"year":1980,"date_issued":"1980-03","date_published":"1980-03","updated_at":"2026-11-20T22:10:12Z","subjects":["Physics"],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/19062","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/19062","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F19062","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Cooper, A.W."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Crittenden, E. C., Jr."]},{"key":"dc:contributor.department","label":"Department","values":["Department of Physics and Chemistry"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School"]},{"key":"dc:creator","label":"Author","values":["Knolhoff, Larry Edward"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["March 1980"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-16T21:01:58Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-16T21:01:58Z"]},{"key":"dc:date.issued","label":"Date","values":["1980-03"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Laser","Stabilization","Stark"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/19062"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Studies have been conducted of the frequency stabilization of the output from a Sylvania 941 Carbon Dioxide laser by active comparison with a Stark-tuned NH(2)D line center in an absorption cell. A dithered Stark voltage gave a peak-detection correction signal fed back to a PZT mounted laser resonator mirror to control the cavity optical length. Operation of an integrator incorporated in the feedback loop to improve the system stability has been investigated. A method was demonstrated of using the integrator to locate the desired laser vibronic transition by scanning the laser through its spectral signature prior to initiation of servo operation. An unexpected discontinuity in the absorption lineshape of a Stark-tunable cell was discovered which made the cell unsuitable for generation of the feedback signal. A new and more versatile Stark cell was designed for test and evaluation of cell plate configuration and fabrication."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/starkcellstabili1094519062"]},{"key":"dc:title","label":"Title","values":["Stark cell stabilization of a CO(2) laser"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Cooper, A.W."],"dc:contributor.committeemember":["Crittenden, E. C., Jr."],"dc:contributor.department":["Department of Physics and Chemistry"],"dc:contributor.other":["Naval Postgraduate School"],"dc:creator":["Knolhoff, Larry Edward"],"dc:date":["March 1980"],"dc:date.accessioned":["2012-11-16T21:01:58Z"],"dc:date.available":["2012-11-16T21:01:58Z"],"dc:date.issued":["1980-03"],"dc:description.abstract":["Studies have been conducted of the frequency stabilization of the output from a Sylvania 941 Carbon Dioxide laser by active comparison with a Stark-tuned NH(2)D line center in an absorption cell. A dithered Stark voltage gave a peak-detection correction signal fed back to a PZT mounted laser resonator mirror to control the cavity optical length. Operation of an integrator incorporated in the feedback loop to improve the system stability has been investigated. A method was demonstrated of using the integrator to locate the desired laser vibronic transition by scanning the laser through its spectral signature prior to initiation of servo operation. An unexpected discontinuity in the absorption lineshape of a Stark-tunable cell was discovered which made the cell unsuitable for generation of the feedback signal. A new and more versatile Stark cell was designed for test and evaluation of cell plate configuration and fabrication."],"dc:description.uri":["http://archive.org/details/starkcellstabili1094519062"],"dc:identifier.uri":["https://hdl.handle.net/10945/19062"],"dc:publisher":["Monterey, California; Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Laser","Stabilization","Stark"],"dc:subject.lcsh":["Physics"],"dc:title":["Stark cell stabilization of a CO(2) laser"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Physics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-20T22:10:12Z"}