{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/19491"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/19491","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Particle sizing from forward scattered light at two angles using a variable-focal-length optical system","abstract":"The theory of operation and description of a particle sizing device which indirectly determines the size of small particles from forward scattered light at two angles is presented. The device incorporates a fixed detector geometry and maintains a fixed intensity ratio at two photodiode detectors by adjusting the optical system focal length. Simple analogue signal processing is used with a servomotor to make continuous adjustments automatically. The optical device is used to investigate the effects of an applied high intensity electric field on a fuel spray from a turbine engine fuel nozzle for changes in droplet size. Preliminary results on a T-56 nozzle spraying DF-2 fuel at 75 psig with the sample volume 8 centimeters from the nozzle and using a sharp electrode with the point 10 millimeters from the nozzle at a potential of 16 kV showed no conclusive changes in droplet size. The Sauter mean diameter of the fuel spray varied from 42 to 47 microns. Keywords include: Particle measurement, and Variable-focal-length optical system","abstract_html":"The theory of operation and description of a particle sizing device which indirectly determines the size of small particles from forward scattered light at two angles is presented. The device incorporates a fixed detector geometry and maintains a fixed intensity ratio at two photodiode detectors by adjusting the optical system focal length. Simple analogue signal processing is used with a servomotor to make continuous adjustments automatically. The optical device is used to investigate the effects of an applied high intensity electric field on a fuel spray from a turbine engine fuel nozzle for changes in droplet size. Preliminary results on a T-56 nozzle spraying DF-2 fuel at 75 psig with the sample volume 8 centimeters from the nozzle and using a sharp electrode with the point 10 millimeters from the nozzle at a potential of 16 kV showed no conclusive changes in droplet size. The Sauter mean diameter of the fuel spray varied from 42 to 47 microns. Keywords include: Particle measurement, and Variable-focal-length optical system","abstract_has_math":false,"creators":["Powers, John"],"institution":"Naval Postgraduate School","degree_name":"M.S. in Aeronautical Engineering","degree_level":"Masters","degree_discipline":"Aeronautical Engineering","degree_department":null,"school":"NA","contributors":[],"advisors":[],"committee_chairs":[],"committee_members":["NA"],"year":1984,"date_issued":"1984","date_published":"1984","updated_at":"2026-11-21T22:23:57Z","subjects":["Aeronautics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["ocm227644892"],"render_values":[{"text":"ocm227644892","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/19491","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/19491","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F19491","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F19491","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["NA"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["NA"]},{"key":"dc:contributor.school","label":"School","values":["NA"]},{"key":"dc:creator","label":"Author","values":["Powers, John"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-19T23:51:01Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-19T23:51:01Z"]},{"key":"dc:date.issued","label":"Date","values":["1984"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Aeronautical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Aeronautical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["NA"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Aeronautics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["ocm227644892"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/19491"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The theory of operation and description of a particle sizing device which indirectly determines the size of small particles from forward scattered light at two angles is presented. The device incorporates a fixed detector geometry and maintains a fixed intensity ratio at two photodiode detectors by adjusting the optical system focal length. Simple analogue signal processing is used with a servomotor to make continuous adjustments automatically. The optical device is used to investigate the effects of an applied high intensity electric field on a fuel spray from a turbine engine fuel nozzle for changes in droplet size. Preliminary results on a T-56 nozzle spraying DF-2 fuel at 75 psig with the sample volume 8 centimeters from the nozzle and using a sharp electrode with the point 10 millimeters from the nozzle at a potential of 16 kV showed no conclusive changes in droplet size. The Sauter mean diameter of the fuel spray varied from 42 to 47 microns. Keywords include: Particle measurement, and Variable-focal-length optical system"]},{"key":"dc:description.award","label":"Dc Description Award","values":["NA"]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["NA"]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/particlesizingfr1094519491"]},{"key":"dc:title","label":"Title","values":["Particle sizing from forward scattered light at two angles using a variable-focal-length optical system"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["U.S. Navy (U.S.N.) author."]}]}],"canonical_facts":{"dc:contributor.committeemember":["NA"],"dc:contributor.other":["NA"],"dc:contributor.school":["NA"],"dc:creator":["Powers, John"],"dc:date.accessioned":["2012-11-19T23:51:01Z"],"dc:date.available":["2012-11-19T23:51:01Z"],"dc:date.issued":["1984"],"dc:description.abstract":["The theory of operation and description of a particle sizing device which indirectly determines the size of small particles from forward scattered light at two angles is presented. The device incorporates a fixed detector geometry and maintains a fixed intensity ratio at two photodiode detectors by adjusting the optical system focal length. Simple analogue signal processing is used with a servomotor to make continuous adjustments automatically. The optical device is used to investigate the effects of an applied high intensity electric field on a fuel spray from a turbine engine fuel nozzle for changes in droplet size. Preliminary results on a T-56 nozzle spraying DF-2 fuel at 75 psig with the sample volume 8 centimeters from the nozzle and using a sharp electrode with the point 10 millimeters from the nozzle at a potential of 16 kV showed no conclusive changes in droplet size. The Sauter mean diameter of the fuel spray varied from 42 to 47 microns. Keywords include: Particle measurement, and Variable-focal-length optical system"],"dc:description.award":["NA"],"dc:description.sponsorship":["NA"],"dc:description.uri":["http://archive.org/details/particlesizingfr1094519491"],"dc:identifier.oclc":["ocm227644892"],"dc:identifier.uri":["https://hdl.handle.net/10945/19491"],"dc:subject.keyword":["NA"],"dc:subject.lcsh":["Aeronautics"],"dc:title":["Particle sizing from forward scattered light at two angles using a variable-focal-length optical system"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["U.S. Navy (U.S.N.) author."],"thesis:degree_discipline":["Aeronautical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Aeronautical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T22:23:57Z"}