{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/19639"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/19639","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Analysis and testing of the thermal design of the electrical package in the U.S. Army's Upgraded Logic Module (ULM)","abstract":"The U.S. Army has developed an Upgraded Logic Module (ULM) for use in its Infantry Direct Fire Simulator System (IDFSS). It is designed to analyze data collected from associated instrumentation according to prescribed programming, to report results back to the system control via a telemetry interface, and it can be backpack mounted. The thermal environment existing at Ft. Hunter Liggett, Ca. (the primary operating environment for the ULM) during the summer will add an abnormal thermal load to the ULM operating environment in the backpack. A mock-up of the actual ULM was built to model the heat dissipation of all the components and tested in different environments using extreme power consumption rates. The actual ULM was tested with typical power consumption rates and various environmental temperatures, including solar loading. Under typical operating conditions, the ULM will remain within manufacturer's tolerances for individual component temperatures. However slight increases in power consumption rates will severely stress the reliability limits of certain components, and the reliability of the entire system cannot be predicted.","abstract_html":"The U.S. Army has developed an Upgraded Logic Module (ULM) for use in its Infantry Direct Fire Simulator System (IDFSS). It is designed to analyze data collected from associated instrumentation according to prescribed programming, to report results back to the system control via a telemetry interface, and it can be backpack mounted. The thermal environment existing at Ft. Hunter Liggett, Ca. (the primary operating environment for the ULM) during the summer will add an abnormal thermal load to the ULM operating environment in the backpack. A mock-up of the actual ULM was built to model the heat dissipation of all the components and tested in different environments using extreme power consumption rates. The actual ULM was tested with typical power consumption rates and various environmental temperatures, including solar loading. Under typical operating conditions, the ULM will remain within manufacturer&#x27;s tolerances for individual component temperatures. However slight increases in power consumption rates will severely stress the reliability limits of certain components, and the reliability of the entire system cannot be predicted.","abstract_has_math":false,"creators":["Keebler, Henry C. III"],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Kelleher, Matthew"],"committee_chairs":[],"committee_members":["Marto, Paul J."],"year":1983,"date_issued":"1983-09","date_published":"1983-09","updated_at":"2026-11-21T23:26:31Z","subjects":["Mechanical engineering"],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/19639","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/19639","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F19639","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F19639","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Kelleher, Matthew"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Marto, Paul J."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Keebler, Henry C. III"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["September 1983"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-19T23:57:27Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-19T23:57:27Z"]},{"key":"dc:date.issued","label":"Date","values":["1983-09"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Upgraded logic module (ULM)","Thermal design","Electronic packaging"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/19639"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The U.S. Army has developed an Upgraded Logic Module (ULM) for use in its Infantry Direct Fire Simulator System (IDFSS). It is designed to analyze data collected from associated instrumentation according to prescribed programming, to report results back to the system control via a telemetry interface, and it can be backpack mounted. The thermal environment existing at Ft. Hunter Liggett, Ca. (the primary operating environment for the ULM) during the summer will add an abnormal thermal load to the ULM operating environment in the backpack. A mock-up of the actual ULM was built to model the heat dissipation of all the components and tested in different environments using extreme power consumption rates. The actual ULM was tested with typical power consumption rates and various environmental temperatures, including solar loading. Under typical operating conditions, the ULM will remain within manufacturer's tolerances for individual component temperatures. However slight increases in power consumption rates will severely stress the reliability limits of certain components, and the reliability of the entire system cannot be predicted."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/analysisndtestin1094519639"]},{"key":"dc:title","label":"Title","values":["Analysis and testing of the thermal design of the electrical package in the U.S. Army's Upgraded Logic Module (ULM)"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Captain, United States Army"]}]}],"canonical_facts":{"dc:contributor.advisor":["Kelleher, Matthew"],"dc:contributor.committeemember":["Marto, Paul J."],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Keebler, Henry C. III"],"dc:date":["September 1983"],"dc:date.accessioned":["2012-11-19T23:57:27Z"],"dc:date.available":["2012-11-19T23:57:27Z"],"dc:date.issued":["1983-09"],"dc:description.abstract":["The U.S. Army has developed an Upgraded Logic Module (ULM) for use in its Infantry Direct Fire Simulator System (IDFSS). It is designed to analyze data collected from associated instrumentation according to prescribed programming, to report results back to the system control via a telemetry interface, and it can be backpack mounted. The thermal environment existing at Ft. Hunter Liggett, Ca. (the primary operating environment for the ULM) during the summer will add an abnormal thermal load to the ULM operating environment in the backpack. A mock-up of the actual ULM was built to model the heat dissipation of all the components and tested in different environments using extreme power consumption rates. The actual ULM was tested with typical power consumption rates and various environmental temperatures, including solar loading. Under typical operating conditions, the ULM will remain within manufacturer's tolerances for individual component temperatures. However slight increases in power consumption rates will severely stress the reliability limits of certain components, and the reliability of the entire system cannot be predicted."],"dc:description.uri":["http://archive.org/details/analysisndtestin1094519639"],"dc:identifier.uri":["https://hdl.handle.net/10945/19639"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Upgraded logic module (ULM)","Thermal design","Electronic packaging"],"dc:subject.lcsh":["Mechanical engineering"],"dc:title":["Analysis and testing of the thermal design of the electrical package in the U.S. Army's Upgraded Logic Module (ULM)"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Captain, United States Army"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T23:26:31Z"}