{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/20101"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/20101","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"A comparison of the tube-side performance of enhanced heat transfer tubing for naval condensers","abstract":"The data of several investigators conducting research in the area of enhanced heat transfer in internally ribbed and spirally corrugated tubes is compiled and examined to determine the effects of the geometric characteristics of enhanced tubing on flow resistance and heat transfer. The data are compared to determine if there are any relations, either new or previously published, which can be of use to the designer to predict the friction factor and heat transfer coefficient for a specified enhanced tube. Empirical relations are recommended for friction factor and heat transfer coefficient for single-start and multiplestart spirally corrugated tubes based on the lav/ of the wall similarity analysis and a heat transfer similarity analysis. The empirical relations are compared to experimental data for single-start and multiple-start corrugated tubes with pitch-to-groove ratios greater than 10 and dimensionless groove depths less than 0.05. The recommended relations correlate with the experimental data for heat transfer coefficient within ±15% for 94% of the specified tubes.","abstract_html":"The data of several investigators conducting research in the area of enhanced heat transfer in internally ribbed and spirally corrugated tubes is compiled and examined to determine the effects of the geometric characteristics of enhanced tubing on flow resistance and heat transfer. The data are compared to determine if there are any relations, either new or previously published, which can be of use to the designer to predict the friction factor and heat transfer coefficient for a specified enhanced tube. Empirical relations are recommended for friction factor and heat transfer coefficient for single-start and multiplestart spirally corrugated tubes based on the lav/ of the wall similarity analysis and a heat transfer similarity analysis. The empirical relations are compared to experimental data for single-start and multiple-start corrugated tubes with pitch-to-groove ratios greater than 10 and dimensionless groove depths less than 0.05. The recommended relations correlate with the experimental data for heat transfer coefficient within ±15% for 94% of the specified tubes.","abstract_has_math":false,"creators":["Alexander, Ronald Keith"],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":"Naval Postgraduate School","contributors":[],"advisors":["Marto, P.J."],"committee_chairs":[],"committee_members":["Kelleher, Matthew"],"year":1982,"date_issued":"1982-12","date_published":"1982-12","updated_at":"2026-11-21T22:47:20Z","subjects":["Mechanical engineering"],"languages":[],"rights":["Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["NPS69-82-008"],"render_values":[{"text":"NPS69-82-008","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/20101","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/20101","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F20101","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Marto, P.J."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Kelleher, Matthew"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School"]},{"key":"dc:contributor.school","label":"School","values":["Naval Postgraduate School"]},{"key":"dc:creator","label":"Author","values":["Alexander, Ronald Keith"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-20T00:07:02Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-20T00:07:02Z"]},{"key":"dc:date.issued","label":"Date","values":["1982-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Heat Transfer Coefficients","Friction Factors","Augmentation"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["NPS69-82-008"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/20101"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The data of several investigators conducting research in the area of enhanced heat transfer in internally ribbed and spirally corrugated tubes is compiled and examined to determine the effects of the geometric characteristics of enhanced tubing on flow resistance and heat transfer. The data are compared to determine if there are any relations, either new or previously published, which can be of use to the designer to predict the friction factor and heat transfer coefficient for a specified enhanced tube. Empirical relations are recommended for friction factor and heat transfer coefficient for single-start and multiplestart spirally corrugated tubes based on the lav/ of the wall similarity analysis and a heat transfer similarity analysis. The empirical relations are compared to experimental data for single-start and multiple-start corrugated tubes with pitch-to-groove ratios greater than 10 and dimensionless groove depths less than 0.05. The recommended relations correlate with the experimental data for heat transfer coefficient within ±15% for 94% of the specified tubes."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["This thesis is prepared in conjunction with research supported in part by David Taylor Ship Reserach and Development Center under N00167-WR2-0114."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/acomparisonoftub1094520101"]},{"key":"dc:title","label":"Title","values":["A comparison of the tube-side performance of enhanced heat transfer tubing for naval condensers"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant Commander, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Marto, P.J."],"dc:contributor.committeemember":["Kelleher, Matthew"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["Naval Postgraduate School"],"dc:contributor.school":["Naval Postgraduate School"],"dc:creator":["Alexander, Ronald Keith"],"dc:date.accessioned":["2012-11-20T00:07:02Z"],"dc:date.available":["2012-11-20T00:07:02Z"],"dc:date.issued":["1982-12"],"dc:description.abstract":["The data of several investigators conducting research in the area of enhanced heat transfer in internally ribbed and spirally corrugated tubes is compiled and examined to determine the effects of the geometric characteristics of enhanced tubing on flow resistance and heat transfer. The data are compared to determine if there are any relations, either new or previously published, which can be of use to the designer to predict the friction factor and heat transfer coefficient for a specified enhanced tube. Empirical relations are recommended for friction factor and heat transfer coefficient for single-start and multiplestart spirally corrugated tubes based on the lav/ of the wall similarity analysis and a heat transfer similarity analysis. The empirical relations are compared to experimental data for single-start and multiple-start corrugated tubes with pitch-to-groove ratios greater than 10 and dimensionless groove depths less than 0.05. The recommended relations correlate with the experimental data for heat transfer coefficient within ±15% for 94% of the specified tubes."],"dc:description.sponsorship":["This thesis is prepared in conjunction with research supported in part by David Taylor Ship Reserach and Development Center under N00167-WR2-0114."],"dc:description.uri":["http://archive.org/details/acomparisonoftub1094520101"],"dc:identifier.other":["NPS69-82-008"],"dc:identifier.uri":["https://hdl.handle.net/10945/20101"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Heat Transfer Coefficients","Friction Factors","Augmentation"],"dc:subject.lcsh":["Mechanical engineering"],"dc:title":["A comparison of the tube-side performance of enhanced heat transfer tubing for naval condensers"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant Commander, United States Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T22:47:20Z"}