{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/21141"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/21141","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Analysis of contrast sensitivity and spectral response of imaging systems.","abstract":"The characteristics of imaging systems CID, CCD and VIDICON were investigated in terms of the contrast sensitivity and the spectral response in the near infrared region. The object distance of 83.5cm², the radiant flux density of 0.93 microwatts/cm and a black and white bar chart were used for the measurement of CTF. The spectral response was measured at 2520 °K using a tungsten light source. The CID image sensor has high sensitivity, resolving capability and spectral response at low light level comparing to the CCD or VIDICON. The limiting resolution values of 23.0 line-pairs/mm for CCD and 28.4 line-pairs/ mm for VIDICON, the cutoff wavelengths of 1.0 micrometers for CCD and 0.94 micrometers for VIDICON were determined. The limiting resolution value and the cutoff wavelength for CID were much higher than those of CCD or VIDICON and lay outside the range of this experiment.","abstract_html":"The characteristics of imaging systems CID, CCD and VIDICON were investigated in terms of the contrast sensitivity and the spectral response in the near infrared region. The object distance of 83.5cm², the radiant flux density of 0.93 microwatts/cm and a black and white bar chart were used for the measurement of CTF. The spectral response was measured at 2520 °K using a tungsten light source. The CID image sensor has high sensitivity, resolving capability and spectral response at low light level comparing to the CCD or VIDICON. The limiting resolution values of 23.0 line-pairs/mm for CCD and 28.4 line-pairs/ mm for VIDICON, the cutoff wavelengths of 1.0 micrometers for CCD and 0.94 micrometers for VIDICON were determined. The limiting resolution value and the cutoff wavelength for CID were much higher than those of CCD or VIDICON and lay outside the range of this experiment.","abstract_has_math":false,"creators":["Kim, Young Soo"],"institution":"Naval Postgraduate School","degree_name":"M.S. in Physics","degree_level":"Masters","degree_discipline":"Physics","degree_department":"Physics","school":null,"contributors":[],"advisors":["Milne, Edmund A."],"committee_chairs":[],"committee_members":["Cooper, Alfred W."],"year":1985,"date_issued":"1985-12","date_published":"1985-12","updated_at":"2026-11-20T22:04:06Z","subjects":["Physics"],"languages":[],"rights":["Copyright is reserved by the copyright owner","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/21141","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/21141","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F21141","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F21141","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Milne, Edmund A."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Cooper, Alfred W."]},{"key":"dc:contributor.department","label":"Department","values":["Physics"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Kim, Young Soo"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["December 1985"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-26T23:59:58Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-26T23:59:58Z"]},{"key":"dc:date.issued","label":"Date","values":["1985-12"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["CID","CCD","VIDICON","noise","limiting resolution","contrast sensitivity","spectral response"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Copyright is reserved by the copyright owner","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/21141"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The characteristics of imaging systems CID, CCD and VIDICON were investigated in terms of the contrast sensitivity and the spectral response in the near infrared region. The object distance of 83.5cm², the radiant flux density of 0.93 microwatts/cm and a black and white bar chart were used for the measurement of CTF. The spectral response was measured at 2520 °K using a tungsten light source. The CID image sensor has high sensitivity, resolving capability and spectral response at low light level comparing to the CCD or VIDICON. The limiting resolution values of 23.0 line-pairs/mm for CCD and 28.4 line-pairs/ mm for VIDICON, the cutoff wavelengths of 1.0 micrometers for CCD and 0.94 micrometers for VIDICON were determined. The limiting resolution value and the cutoff wavelength for CID were much higher than those of CCD or VIDICON and lay outside the range of this experiment."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/analysisofcontra1094521141"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["46 p."]},{"key":"dc:title","label":"Title","values":["Analysis of contrast sensitivity and spectral response of imaging systems."]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, Korean Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Milne, Edmund A."],"dc:contributor.committeemember":["Cooper, Alfred W."],"dc:contributor.department":["Physics"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Kim, Young Soo"],"dc:date":["December 1985"],"dc:date.accessioned":["2012-11-26T23:59:58Z"],"dc:date.available":["2012-11-26T23:59:58Z"],"dc:date.issued":["1985-12"],"dc:description.abstract":["The characteristics of imaging systems CID, CCD and VIDICON were investigated in terms of the contrast sensitivity and the spectral response in the near infrared region. The object distance of 83.5cm², the radiant flux density of 0.93 microwatts/cm and a black and white bar chart were used for the measurement of CTF. The spectral response was measured at 2520 °K using a tungsten light source. The CID image sensor has high sensitivity, resolving capability and spectral response at low light level comparing to the CCD or VIDICON. The limiting resolution values of 23.0 line-pairs/mm for CCD and 28.4 line-pairs/ mm for VIDICON, the cutoff wavelengths of 1.0 micrometers for CCD and 0.94 micrometers for VIDICON were determined. The limiting resolution value and the cutoff wavelength for CID were much higher than those of CCD or VIDICON and lay outside the range of this experiment."],"dc:description.uri":["http://archive.org/details/analysisofcontra1094521141"],"dc:format.extent":["46 p."],"dc:identifier.uri":["https://hdl.handle.net/10945/21141"],"dc:rights":["Copyright is reserved by the copyright owner","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["CID","CCD","VIDICON","noise","limiting resolution","contrast sensitivity","spectral response"],"dc:subject.lcsh":["Physics"],"dc:title":["Analysis of contrast sensitivity and spectral response of imaging systems."],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, Korean Navy"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Physics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-20T22:04:06Z"}