{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/21288"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/21288","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"The effectiveness of heat exchangers with one shell pass and five tube passes.","abstract":"Heat exchangers with one shell pass and n tube passes are often referred to as 1-n exchangers. The heat transfer literature contains many references to studies of 1-n exchangers when n is even but apparently, other than a single study and some work pertaining to the 1-3 exchanger at the Naval Postgraduate School, little work has been done with respect to the 1-n exchanger when n is odd. This thesis expands upon the study of 1-n exchangers with n being odd. While a completely closed form solution was found to be unfeasible, a polynomial approximation has been developed that yields the effectiveness (e) of the two possible arrangements of the 1-5 exchanger as a function of the capacity rate ratio (R) and the number of transfer units (N(tu) ). This will enable the analyst to consider exchangers where the inlet to and outlet from the tubes are at opposite ends of the exchanger.","abstract_html":"Heat exchangers with one shell pass and n tube passes are often referred to as 1-n exchangers. The heat transfer literature contains many references to studies of 1-n exchangers when n is even but apparently, other than a single study and some work pertaining to the 1-3 exchanger at the Naval Postgraduate School, little work has been done with respect to the 1-n exchanger when n is odd. This thesis expands upon the study of 1-n exchangers with n being odd. While a completely closed form solution was found to be unfeasible, a polynomial approximation has been developed that yields the effectiveness (e) of the two possible arrangements of the 1-5 exchanger as a function of the capacity rate ratio (R) and the number of transfer units (N(tu) ). This will enable the analyst to consider exchangers where the inlet to and outlet from the tubes are at opposite ends of the exchanger.","abstract_has_math":false,"creators":["Hess, Lawrence E."],"institution":"Naval Postgraduate School","degree_name":"M.S. in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Kraus, Allan D."],"committee_chairs":[],"committee_members":[],"year":1985,"date_issued":"1985-09","date_published":"1985-09","updated_at":"2026-11-21T23:37:59Z","subjects":["Mechanical engineering"],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/21288","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/21288","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F21288","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F21288","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Kraus, Allan D."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Hess, Lawrence E."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["September 1985"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-27T00:01:05Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-27T00:01:05Z"]},{"key":"dc:date.issued","label":"Date","values":["1985-09"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["heat exchanger","effectiveness N(tu) method","five tube pass"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/21288"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Heat exchangers with one shell pass and n tube passes are often referred to as 1-n exchangers. The heat transfer literature contains many references to studies of 1-n exchangers when n is even but apparently, other than a single study and some work pertaining to the 1-3 exchanger at the Naval Postgraduate School, little work has been done with respect to the 1-n exchanger when n is odd. This thesis expands upon the study of 1-n exchangers with n being odd. While a completely closed form solution was found to be unfeasible, a polynomial approximation has been developed that yields the effectiveness (e) of the two possible arrangements of the 1-5 exchanger as a function of the capacity rate ratio (R) and the number of transfer units (N(tu) ). This will enable the analyst to consider exchangers where the inlet to and outlet from the tubes are at opposite ends of the exchanger."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/theeffectiveness1094521288"]},{"key":"dc:title","label":"Title","values":["The effectiveness of heat exchangers with one shell pass and five tube passes."]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant Commander, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Kraus, Allan D."],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Hess, Lawrence E."],"dc:date":["September 1985"],"dc:date.accessioned":["2012-11-27T00:01:05Z"],"dc:date.available":["2012-11-27T00:01:05Z"],"dc:date.issued":["1985-09"],"dc:description.abstract":["Heat exchangers with one shell pass and n tube passes are often referred to as 1-n exchangers. The heat transfer literature contains many references to studies of 1-n exchangers when n is even but apparently, other than a single study and some work pertaining to the 1-3 exchanger at the Naval Postgraduate School, little work has been done with respect to the 1-n exchanger when n is odd. This thesis expands upon the study of 1-n exchangers with n being odd. While a completely closed form solution was found to be unfeasible, a polynomial approximation has been developed that yields the effectiveness (e) of the two possible arrangements of the 1-5 exchanger as a function of the capacity rate ratio (R) and the number of transfer units (N(tu) ). This will enable the analyst to consider exchangers where the inlet to and outlet from the tubes are at opposite ends of the exchanger."],"dc:description.uri":["http://archive.org/details/theeffectiveness1094521288"],"dc:identifier.uri":["https://hdl.handle.net/10945/21288"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["heat exchanger","effectiveness N(tu) method","five tube pass"],"dc:subject.lcsh":["Mechanical engineering"],"dc:title":["The effectiveness of heat exchangers with one shell pass and five tube passes."],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant Commander, United States Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T23:37:59Z"}