{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/21291"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/21291","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"The effect of condensate inundation on steam condensation heat transfer in a tube bundle","abstract":"Steam-condensation heat-transfer measurements were made using a 5-tube in-line test condenser with an additional perforated tube to simulate up to 30 active tubes. Results were obtained for smooth tubes, wire-wrapped tubes and dropwise-coated tubes. The average outside heat-transfer coefficient for 30 smooth tubes was 0.64 times the Nusselt coefficient for the first tube. A total of eight wirediameter and wire-pitch combinations were tested: 1.6-mmdiameter wire wrapped at 16 mm, 7.6 mm and 4 mm wire pitches, 1 . 0-mm-diameter wire wrapped at 8 mm, 4 mm and 2 mm wire pitches, and . 5-mm-diameter wire wrapped at 4 mm and 2 mm wire pitches. The best bundle performance was obtained when the tubes were wrapped with 1 .0-mm-diameter wire at a wire pitch of 4 mm. This combination resulted in an average outside heat-transfer coefficient for 30 tubes that was 1.15 times the value computed for the first tube using the Nusselt theory. The average outside heat-transfer coefficient for the 30 dropwise-coated tubes was 1.1 times the value of the heat- transfer coefficient for the first tube in the tube bundle. Utilizing either wire-wrapped tubes or dropwisecoated tubes, it is possible to significantly reduce the condenser surface area and overall size.","abstract_html":"Steam-condensation heat-transfer measurements were made using a 5-tube in-line test condenser with an additional perforated tube to simulate up to 30 active tubes. Results were obtained for smooth tubes, wire-wrapped tubes and dropwise-coated tubes. The average outside heat-transfer coefficient for 30 smooth tubes was 0.64 times the Nusselt coefficient for the first tube. A total of eight wirediameter and wire-pitch combinations were tested: 1.6-mmdiameter wire wrapped at 16 mm, 7.6 mm and 4 mm wire pitches, 1 . 0-mm-diameter wire wrapped at 8 mm, 4 mm and 2 mm wire pitches, and . 5-mm-diameter wire wrapped at 4 mm and 2 mm wire pitches. The best bundle performance was obtained when the tubes were wrapped with 1 .0-mm-diameter wire at a wire pitch of 4 mm. This combination resulted in an average outside heat-transfer coefficient for 30 tubes that was 1.15 times the value computed for the first tube using the Nusselt theory. The average outside heat-transfer coefficient for the 30 dropwise-coated tubes was 1.1 times the value of the heat- transfer coefficient for the first tube in the tube bundle. Utilizing either wire-wrapped tubes or dropwisecoated tubes, it is possible to significantly reduce the condenser surface area and overall size.","abstract_has_math":false,"creators":["Brower, Steven K."],"institution":"Naval Postgraduate School","degree_name":"M.S. in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":"Naval Postgraduate School","contributors":[],"advisors":["Marto, P.J.","Wanniarachchi, A.S."],"committee_chairs":[],"committee_members":[],"year":1985,"date_issued":"1985-06","date_published":"1985-06","updated_at":"2026-11-20T22:07:38Z","subjects":["Mechanical engineering"],"languages":[],"rights":["Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/21291","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/21291","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F21291","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F21291","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Marto, P.J.","Wanniarachchi, A.S."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School"]},{"key":"dc:contributor.school","label":"School","values":["Naval Postgraduate School"]},{"key":"dc:creator","label":"Author","values":["Brower, Steven K."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-27T00:01:07Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-27T00:01:07Z"]},{"key":"dc:date.issued","label":"Date","values":["1985-06"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Steam condensation","heat-transfer coefficient","inundation","smooth","wire-wrapped tubes"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/21291"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Steam-condensation heat-transfer measurements were made using a 5-tube in-line test condenser with an additional perforated tube to simulate up to 30 active tubes. Results were obtained for smooth tubes, wire-wrapped tubes and dropwise-coated tubes. The average outside heat-transfer coefficient for 30 smooth tubes was 0.64 times the Nusselt coefficient for the first tube. A total of eight wirediameter and wire-pitch combinations were tested: 1.6-mmdiameter wire wrapped at 16 mm, 7.6 mm and 4 mm wire pitches, 1 . 0-mm-diameter wire wrapped at 8 mm, 4 mm and 2 mm wire pitches, and . 5-mm-diameter wire wrapped at 4 mm and 2 mm wire pitches. The best bundle performance was obtained when the tubes were wrapped with 1 .0-mm-diameter wire at a wire pitch of 4 mm. This combination resulted in an average outside heat-transfer coefficient for 30 tubes that was 1.15 times the value computed for the first tube using the Nusselt theory. The average outside heat-transfer coefficient for the 30 dropwise-coated tubes was 1.1 times the value of the heat- transfer coefficient for the first tube in the tube bundle. Utilizing either wire-wrapped tubes or dropwisecoated tubes, it is possible to significantly reduce the condenser surface area and overall size."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/theeffectofconde1094521291"]},{"key":"dc:title","label":"Title","values":["The effect of condensate inundation on steam condensation heat transfer in a tube bundle"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Marto, P.J.","Wanniarachchi, A.S."],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["Naval Postgraduate School"],"dc:contributor.school":["Naval Postgraduate School"],"dc:creator":["Brower, Steven K."],"dc:date.accessioned":["2012-11-27T00:01:07Z"],"dc:date.available":["2012-11-27T00:01:07Z"],"dc:date.issued":["1985-06"],"dc:description.abstract":["Steam-condensation heat-transfer measurements were made using a 5-tube in-line test condenser with an additional perforated tube to simulate up to 30 active tubes. Results were obtained for smooth tubes, wire-wrapped tubes and dropwise-coated tubes. The average outside heat-transfer coefficient for 30 smooth tubes was 0.64 times the Nusselt coefficient for the first tube. A total of eight wirediameter and wire-pitch combinations were tested: 1.6-mmdiameter wire wrapped at 16 mm, 7.6 mm and 4 mm wire pitches, 1 . 0-mm-diameter wire wrapped at 8 mm, 4 mm and 2 mm wire pitches, and . 5-mm-diameter wire wrapped at 4 mm and 2 mm wire pitches. The best bundle performance was obtained when the tubes were wrapped with 1 .0-mm-diameter wire at a wire pitch of 4 mm. This combination resulted in an average outside heat-transfer coefficient for 30 tubes that was 1.15 times the value computed for the first tube using the Nusselt theory. The average outside heat-transfer coefficient for the 30 dropwise-coated tubes was 1.1 times the value of the heat- transfer coefficient for the first tube in the tube bundle. Utilizing either wire-wrapped tubes or dropwisecoated tubes, it is possible to significantly reduce the condenser surface area and overall size."],"dc:description.uri":["http://archive.org/details/theeffectofconde1094521291"],"dc:identifier.uri":["https://hdl.handle.net/10945/21291"],"dc:rights":["Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Steam condensation","heat-transfer coefficient","inundation","smooth","wire-wrapped tubes"],"dc:subject.lcsh":["Mechanical engineering"],"dc:title":["The effect of condensate inundation on steam condensation heat transfer in a tube bundle"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-20T22:07:38Z"}