{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/21519"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/21519","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Reciprocity calibration in a compliant cylindrical tube","abstract":"A new method for absolute calibration of electroacoustic transducers is described which permits low frequency reciprocity calibration in a test apparatus of small dimensions. The method takes advantage of the reduced wave speed in a cylindrical water column bounded by a compliant PVC tube to reduce the length of the standing wave to dimensions which can be easily handled in the laboratory. Results of a limited series of experiments show a mean reproducibility of :0.8 decibels in a one-meter long tube at frequencies between 750 and 1100 Hz and sound speeds from 330 to 365 meters/second. The hydrophone voltage sensitivities obtained by the method, however, systematically differ by 1.5 decibels from those measured by comparison with a standard hydrophone; additional research will be required to resolve this discrepancy.","abstract_html":"A new method for absolute calibration of electroacoustic transducers is described which permits low frequency reciprocity calibration in a test apparatus of small dimensions. The method takes advantage of the reduced wave speed in a cylindrical water column bounded by a compliant PVC tube to reduce the length of the standing wave to dimensions which can be easily handled in the laboratory. Results of a limited series of experiments show a mean reproducibility of :0.8 decibels in a one-meter long tube at frequencies between 750 and 1100 Hz and sound speeds from 330 to 365 meters/second. The hydrophone voltage sensitivities obtained by the method, however, systematically differ by 1.5 decibels from those measured by comparison with a standard hydrophone; additional research will be required to resolve this discrepancy.","abstract_has_math":false,"creators":["Johnson, Michael B."],"institution":"Naval Postgraduate School","degree_name":"M.S. in Physics","degree_level":"Masters","degree_discipline":"Physics","degree_department":"Physics","school":null,"contributors":[],"advisors":["Garrett, S.L."],"committee_chairs":[],"committee_members":["Yoon, S.W."],"year":1985,"date_issued":"1985=06","date_published":"1985=06","updated_at":"2026-11-20T22:10:41Z","subjects":["Physics"],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/21519","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/21519","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F21519","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F21519","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Garrett, S.L."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Yoon, S.W."]},{"key":"dc:contributor.department","label":"Department","values":["Physics"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Johnson, Michael B."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["June 1985"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-27T00:02:37Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-27T00:02:37Z"]},{"key":"dc:date.issued","label":"Date","values":["1985=06"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Low-frequency underwater acoustic transducer calibration","Reciprocity calibration"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/21519"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A new method for absolute calibration of electroacoustic transducers is described which permits low frequency reciprocity calibration in a test apparatus of small dimensions. The method takes advantage of the reduced wave speed in a cylindrical water column bounded by a compliant PVC tube to reduce the length of the standing wave to dimensions which can be easily handled in the laboratory. Results of a limited series of experiments show a mean reproducibility of :0.8 decibels in a one-meter long tube at frequencies between 750 and 1100 Hz and sound speeds from 330 to 365 meters/second. The hydrophone voltage sensitivities obtained by the method, however, systematically differ by 1.5 decibels from those measured by comparison with a standard hydrophone; additional research will be required to resolve this discrepancy."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/reciprocitycalib1094521519"]},{"key":"dc:title","label":"Title","values":["Reciprocity calibration in a compliant cylindrical tube"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant Commander, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Garrett, S.L."],"dc:contributor.committeemember":["Yoon, S.W."],"dc:contributor.department":["Physics"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Johnson, Michael B."],"dc:date":["June 1985"],"dc:date.accessioned":["2012-11-27T00:02:37Z"],"dc:date.available":["2012-11-27T00:02:37Z"],"dc:date.issued":["1985=06"],"dc:description.abstract":["A new method for absolute calibration of electroacoustic transducers is described which permits low frequency reciprocity calibration in a test apparatus of small dimensions. The method takes advantage of the reduced wave speed in a cylindrical water column bounded by a compliant PVC tube to reduce the length of the standing wave to dimensions which can be easily handled in the laboratory. Results of a limited series of experiments show a mean reproducibility of :0.8 decibels in a one-meter long tube at frequencies between 750 and 1100 Hz and sound speeds from 330 to 365 meters/second. The hydrophone voltage sensitivities obtained by the method, however, systematically differ by 1.5 decibels from those measured by comparison with a standard hydrophone; additional research will be required to resolve this discrepancy."],"dc:description.uri":["http://archive.org/details/reciprocitycalib1094521519"],"dc:identifier.uri":["https://hdl.handle.net/10945/21519"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Low-frequency underwater acoustic transducer calibration","Reciprocity calibration"],"dc:subject.lcsh":["Physics"],"dc:title":["Reciprocity calibration in a compliant cylindrical tube"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant Commander, United States Navy"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Physics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-20T22:10:41Z"}