{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/21602"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/21602","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"The use of austenitic stainless steel versus monel (Ni-Cu) alloy in pressurized gaseous oxygen (GOX) life support systems.","abstract":"Gaseous oxygen (GOX) must be stored at pressures up to 24 MPa (3500 psi) to provide the flow rates required to support the metabolic needs of a diver. A review of the literature concerned with materials compatibility in pressurized oxygen systems was conducted, with emphasis on metallic structural materials. Review of experimental and theoretical work on combustion of austenitic stainless steels and nickel-copper alloys revealed a consensus that Monel nominal (63% Ni - 34% Cu) is preferred in high pressure oxygen systems, when its strength and weight are acceptable. At the intermediate pressures, 0.7 to 10.3 MPa (100 to 1500 psi), the relative safety of stainless steel as a structural material is unclear. The testing methods reviewed were friction rubbing, particle impact, fresh metal exposure to heated flowing GOX, promoted ignition and resonance. An experimental apparatus was used to simulate the conditions of GOX flow found in an operational diving set and to compare the flame propagation rates for austenitic stainless steel (AISI 316), Monel (63% Ni - 34% Cu) and carbon steel (AMS 5050) tubing in this environment.","abstract_html":"Gaseous oxygen (GOX) must be stored at pressures up to 24 MPa (3500 psi) to provide the flow rates required to support the metabolic needs of a diver. A review of the literature concerned with materials compatibility in pressurized oxygen systems was conducted, with emphasis on metallic structural materials. Review of experimental and theoretical work on combustion of austenitic stainless steels and nickel-copper alloys revealed a consensus that Monel nominal (63% Ni - 34% Cu) is preferred in high pressure oxygen systems, when its strength and weight are acceptable. At the intermediate pressures, 0.7 to 10.3 MPa (100 to 1500 psi), the relative safety of stainless steel as a structural material is unclear. The testing methods reviewed were friction rubbing, particle impact, fresh metal exposure to heated flowing GOX, promoted ignition and resonance. An experimental apparatus was used to simulate the conditions of GOX flow found in an operational diving set and to compare the flame propagation rates for austenitic stainless steel (AISI 316), Monel (63% Ni - 34% Cu) and carbon steel (AMS 5050) tubing in this environment.","abstract_has_math":false,"creators":["Marsh, Bert"],"institution":"Naval Postgraduate School","degree_name":"M.S. in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["McNelley, T.R."],"committee_chairs":[],"committee_members":["Graham, Kenneth J."],"year":1985,"date_issued":"1985-03","date_published":"1985-03","updated_at":"2026-11-21T22:44:41Z","subjects":["Mechanical engineering"],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/21602","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/21602","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F21602","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["McNelley, T.R."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Graham, Kenneth J."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Marsh, Bert"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["March 1985"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-27T00:03:12Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-27T00:03:12Z"]},{"key":"dc:date.issued","label":"Date","values":["1985-03"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["gaseous oxygen (GOX)","life support systems","Monel","austenitic stainless steel","carbon steel","flame propagation rates"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/21602"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Gaseous oxygen (GOX) must be stored at pressures up to 24 MPa (3500 psi) to provide the flow rates required to support the metabolic needs of a diver. A review of the literature concerned with materials compatibility in pressurized oxygen systems was conducted, with emphasis on metallic structural materials. Review of experimental and theoretical work on combustion of austenitic stainless steels and nickel-copper alloys revealed a consensus that Monel nominal (63% Ni - 34% Cu) is preferred in high pressure oxygen systems, when its strength and weight are acceptable. At the intermediate pressures, 0.7 to 10.3 MPa (100 to 1500 psi), the relative safety of stainless steel as a structural material is unclear. The testing methods reviewed were friction rubbing, particle impact, fresh metal exposure to heated flowing GOX, promoted ignition and resonance. An experimental apparatus was used to simulate the conditions of GOX flow found in an operational diving set and to compare the flame propagation rates for austenitic stainless steel (AISI 316), Monel (63% Ni - 34% Cu) and carbon steel (AMS 5050) tubing in this environment."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/theuseofusteniti1094521602"]},{"key":"dc:title","label":"Title","values":["The use of austenitic stainless steel versus monel (Ni-Cu) alloy in pressurized gaseous oxygen (GOX) life support systems."]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant Commander, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["McNelley, T.R."],"dc:contributor.committeemember":["Graham, Kenneth J."],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Marsh, Bert"],"dc:date":["March 1985"],"dc:date.accessioned":["2012-11-27T00:03:12Z"],"dc:date.available":["2012-11-27T00:03:12Z"],"dc:date.issued":["1985-03"],"dc:description.abstract":["Gaseous oxygen (GOX) must be stored at pressures up to 24 MPa (3500 psi) to provide the flow rates required to support the metabolic needs of a diver. A review of the literature concerned with materials compatibility in pressurized oxygen systems was conducted, with emphasis on metallic structural materials. Review of experimental and theoretical work on combustion of austenitic stainless steels and nickel-copper alloys revealed a consensus that Monel nominal (63% Ni - 34% Cu) is preferred in high pressure oxygen systems, when its strength and weight are acceptable. At the intermediate pressures, 0.7 to 10.3 MPa (100 to 1500 psi), the relative safety of stainless steel as a structural material is unclear. The testing methods reviewed were friction rubbing, particle impact, fresh metal exposure to heated flowing GOX, promoted ignition and resonance. An experimental apparatus was used to simulate the conditions of GOX flow found in an operational diving set and to compare the flame propagation rates for austenitic stainless steel (AISI 316), Monel (63% Ni - 34% Cu) and carbon steel (AMS 5050) tubing in this environment."],"dc:description.uri":["http://archive.org/details/theuseofusteniti1094521602"],"dc:identifier.uri":["https://hdl.handle.net/10945/21602"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["gaseous oxygen (GOX)","life support systems","Monel","austenitic stainless steel","carbon steel","flame propagation rates"],"dc:subject.lcsh":["Mechanical engineering"],"dc:title":["The use of austenitic stainless steel versus monel (Ni-Cu) alloy in pressurized gaseous oxygen (GOX) life support systems."],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant Commander, United States Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T22:44:41Z"}