{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/21842"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/21842","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Examining the effect of transverse motion on retinal biometric identifiers relating to shipboard security mechanisms.","abstract":"The use of retinal biometric identifiers as security devices in shipboard applications was investigated with the use of the DOT 7.5(new version) and DAISY 7. 5( old version) scanners of the Eye-Dentify Co. of Beaverton, Oregon. Motion testing was the primary purpose of the thesis. It was the first occurance of dynamic testing on any type of retinal pattern recognition device. A transverse motion(only) simulator that could roll up to fourteen degrees and sustain a cycle per minute(cpm) rate of 6.0 was constructed and utilized. The nature of the experiment was to test the two scanners to determine if there would be significant differences in the characteristics of the two, and their possible uses at sea. Important conclusions were: 1) The best results occured on the DOT 7.5, although five Type II 'RECOGNITION' errors were noted; 2) As period of roll and angle of roll were increased in cpm's and degrees respectfully, results were poorer; 3) Identification threshold settings were allowed to be set too low at +0. 60 by the CRT lock manager, and should be raised to approximately +0. 70. That way, the probability of the occurance of Type II errors (false RECOGNITIONS/VERIFICATIONS) would be greatly decreased; 4) Retinal scanners are generally, very reliable.","abstract_html":"The use of retinal biometric identifiers as security devices in shipboard applications was investigated with the use of the DOT 7.5(new version) and DAISY 7. 5( old version) scanners of the Eye-Dentify Co. of Beaverton, Oregon. Motion testing was the primary purpose of the thesis. It was the first occurance of dynamic testing on any type of retinal pattern recognition device. A transverse motion(only) simulator that could roll up to fourteen degrees and sustain a cycle per minute(cpm) rate of 6.0 was constructed and utilized. The nature of the experiment was to test the two scanners to determine if there would be significant differences in the characteristics of the two, and their possible uses at sea. Important conclusions were: 1) The best results occured on the DOT 7.5, although five Type II &#x27;RECOGNITION&#x27; errors were noted; 2) As period of roll and angle of roll were increased in cpm&#x27;s and degrees respectfully, results were poorer; 3) Identification threshold settings were allowed to be set too low at +0. 60 by the CRT lock manager, and should be raised to approximately +0. 70. That way, the probability of the occurance of Type II errors (false RECOGNITIONS/VERIFICATIONS) would be greatly decreased; 4) Retinal scanners are generally, very reliable.","abstract_has_math":false,"creators":["Masiero, David Andrew"],"institution":"Naval Postgraduate School","degree_name":"M.S. in Information Systems","degree_level":"Masters","degree_discipline":"Information Systems","degree_department":"Administrative Sciences","school":null,"contributors":[],"advisors":["Poock, Gary K."],"committee_chairs":[],"committee_members":["Whipple, D."],"year":1993,"date_issued":"1993-09","date_published":"1993-09","updated_at":"2026-11-21T23:42:35Z","subjects":["Management"],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/21842","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/21842","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F21842","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F21842","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Poock, Gary K."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Whipple, D."]},{"key":"dc:contributor.department","label":"Department","values":["Administrative Sciences"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Masiero, David Andrew"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["March 1986"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-27T00:16:36Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-27T00:16:36Z"]},{"key":"dc:date.issued","label":"Date","values":["1993-09"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Information Systems"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Information Systems"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["access control","shipboard security","retinal pattern recognition","authorization techniques","retinal biometrics","dynamic testing (shipboard)"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Management"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/21842"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The use of retinal biometric identifiers as security devices in shipboard applications was investigated with the use of the DOT 7.5(new version) and DAISY 7. 5( old version) scanners of the Eye-Dentify Co. of Beaverton, Oregon. Motion testing was the primary purpose of the thesis. It was the first occurance of dynamic testing on any type of retinal pattern recognition device. A transverse motion(only) simulator that could roll up to fourteen degrees and sustain a cycle per minute(cpm) rate of 6.0 was constructed and utilized. The nature of the experiment was to test the two scanners to determine if there would be significant differences in the characteristics of the two, and their possible uses at sea. Important conclusions were: 1) The best results occured on the DOT 7.5, although five Type II 'RECOGNITION' errors were noted; 2) As period of roll and angle of roll were increased in cpm's and degrees respectfully, results were poorer; 3) Identification threshold settings were allowed to be set too low at +0. 60 by the CRT lock manager, and should be raised to approximately +0. 70. That way, the probability of the occurance of Type II errors (false RECOGNITIONS/VERIFICATIONS) would be greatly decreased; 4) Retinal scanners are generally, very reliable."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/examiningeffecto1094521842"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["63 p."]},{"key":"dc:title","label":"Title","values":["Examining the effect of transverse motion on retinal biometric identifiers relating to shipboard security mechanisms."]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Coast Guard"]}]}],"canonical_facts":{"dc:contributor.advisor":["Poock, Gary K."],"dc:contributor.committeemember":["Whipple, D."],"dc:contributor.department":["Administrative Sciences"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Masiero, David Andrew"],"dc:date":["March 1986"],"dc:date.accessioned":["2012-11-27T00:16:36Z"],"dc:date.available":["2012-11-27T00:16:36Z"],"dc:date.issued":["1993-09"],"dc:description.abstract":["The use of retinal biometric identifiers as security devices in shipboard applications was investigated with the use of the DOT 7.5(new version) and DAISY 7. 5( old version) scanners of the Eye-Dentify Co. of Beaverton, Oregon. Motion testing was the primary purpose of the thesis. It was the first occurance of dynamic testing on any type of retinal pattern recognition device. A transverse motion(only) simulator that could roll up to fourteen degrees and sustain a cycle per minute(cpm) rate of 6.0 was constructed and utilized. The nature of the experiment was to test the two scanners to determine if there would be significant differences in the characteristics of the two, and their possible uses at sea. Important conclusions were: 1) The best results occured on the DOT 7.5, although five Type II 'RECOGNITION' errors were noted; 2) As period of roll and angle of roll were increased in cpm's and degrees respectfully, results were poorer; 3) Identification threshold settings were allowed to be set too low at +0. 60 by the CRT lock manager, and should be raised to approximately +0. 70. That way, the probability of the occurance of Type II errors (false RECOGNITIONS/VERIFICATIONS) would be greatly decreased; 4) Retinal scanners are generally, very reliable."],"dc:description.uri":["http://archive.org/details/examiningeffecto1094521842"],"dc:format.extent":["63 p."],"dc:identifier.uri":["https://hdl.handle.net/10945/21842"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["access control","shipboard security","retinal pattern recognition","authorization techniques","retinal biometrics","dynamic testing (shipboard)"],"dc:subject.lcsh":["Management"],"dc:title":["Examining the effect of transverse motion on retinal biometric identifiers relating to shipboard security mechanisms."],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Coast Guard"],"thesis:degree_discipline":["Information Systems"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Information Systems"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T23:42:35Z"}