{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/22449"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/22449","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Reciprocity calibration of an underwater transducer using the Delta-Z Method.","abstract":"a method for determining the free-field open circuit voltage sensitivity of a reversible underwater electroacoustic transducer from the difference in its input electrical impedance when loaded by water and air was investigated theoretically and experimentally. An equation for the sensitivity was derived using reciprocal two-port network theory. The theory takes into account the diffraction due to the finite size of the transducer, its finite mechanical impedance, and its free-field radiation impedance in water, An experiment to test the predictions of the theory was performed using a 6\" diameter, hollow, piezoelectric ceramic spherical transducer. The result of the experiment agreed within several dB with a standard comparison calibration over the frequency range for which both the electrical impedance and comparison calibration data are considered reliable. The calibration method described, which has been termed the Delta-Z method, may be useful for in-situ monitoring of transducer sensitivity in installations which can be flooded and purged.","abstract_html":"a method for determining the free-field open circuit voltage sensitivity of a reversible underwater electroacoustic transducer from the difference in its input electrical impedance when loaded by water and air was investigated theoretically and experimentally. An equation for the sensitivity was derived using reciprocal two-port network theory. The theory takes into account the diffraction due to the finite size of the transducer, its finite mechanical impedance, and its free-field radiation impedance in water, An experiment to test the predictions of the theory was performed using a 6&quot; diameter, hollow, piezoelectric ceramic spherical transducer. The result of the experiment agreed within several dB with a standard comparison calibration over the frequency range for which both the electrical impedance and comparison calibration data are considered reliable. The calibration method described, which has been termed the Delta-Z method, may be useful for in-situ monitoring of transducer sensitivity in installations which can be flooded and purged.","abstract_has_math":false,"creators":["Bedard, Raynald"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S. in Engineering Acoustics","degree_level":"Masters","degree_discipline":"Engineering Acoustics;Electrical Engineering","degree_department":"Engineering Acoustics Academic Committee","school":null,"contributors":[],"advisors":["Baker, Steven R."],"committee_chairs":[],"committee_members":["Michael, Sherif"],"year":1987,"date_issued":"1987","date_published":"1987","updated_at":"2026-11-26T00:20:39Z","subjects":[],"languages":[],"rights":["Copyright is reserved by the copyright owner","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["ocm227713066"],"render_values":[{"text":"ocm227713066","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/22449","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/22449","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F22449","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F22449","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Baker, Steven R."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Michael, Sherif"]},{"key":"dc:contributor.department","label":"Department","values":["Engineering Acoustics Academic Committee","Department of Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Bedard, Raynald"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["December 1987"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-27T00:23:55Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-27T00:23:55Z"]},{"key":"dc:date.issued","label":"Date","values":["1987"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering Acoustics;Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Engineering Acoustics","M.S. in Electrical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["NA","Transducer calibration","Reciprocity calibration","In-situ SONAR calibration","Delta-Z method"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Copyright is reserved by the copyright owner","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["ocm227713066"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/22449"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["a method for determining the free-field open circuit voltage sensitivity of a reversible underwater electroacoustic transducer from the difference in its input electrical impedance when loaded by water and air was investigated theoretically and experimentally. An equation for the sensitivity was derived using reciprocal two-port network theory. The theory takes into account the diffraction due to the finite size of the transducer, its finite mechanical impedance, and its free-field radiation impedance in water, An experiment to test the predictions of the theory was performed using a 6\" diameter, hollow, piezoelectric ceramic spherical transducer. The result of the experiment agreed within several dB with a standard comparison calibration over the frequency range for which both the electrical impedance and comparison calibration data are considered reliable. The calibration method described, which has been termed the Delta-Z method, may be useful for in-situ monitoring of transducer sensitivity in installations which can be flooded and purged."]},{"key":"dc:description.award","label":"Dc Description Award","values":["NA"]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["NA"]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/reciprocitycalib1094522449"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["64 p. 28 cm."]},{"key":"dc:title","label":"Title","values":["Reciprocity calibration of an underwater transducer using the Delta-Z Method."]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Major, Canadian Forces"]}]}],"canonical_facts":{"dc:contributor.advisor":["Baker, Steven R."],"dc:contributor.committeemember":["Michael, Sherif"],"dc:contributor.department":["Engineering Acoustics Academic Committee","Department of Electrical and Computer Engineering"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Bedard, Raynald"],"dc:date":["December 1987"],"dc:date.accessioned":["2012-11-27T00:23:55Z"],"dc:date.available":["2012-11-27T00:23:55Z"],"dc:date.issued":["1987"],"dc:description.abstract":["a method for determining the free-field open circuit voltage sensitivity of a reversible underwater electroacoustic transducer from the difference in its input electrical impedance when loaded by water and air was investigated theoretically and experimentally. An equation for the sensitivity was derived using reciprocal two-port network theory. The theory takes into account the diffraction due to the finite size of the transducer, its finite mechanical impedance, and its free-field radiation impedance in water, An experiment to test the predictions of the theory was performed using a 6\" diameter, hollow, piezoelectric ceramic spherical transducer. The result of the experiment agreed within several dB with a standard comparison calibration over the frequency range for which both the electrical impedance and comparison calibration data are considered reliable. The calibration method described, which has been termed the Delta-Z method, may be useful for in-situ monitoring of transducer sensitivity in installations which can be flooded and purged."],"dc:description.award":["NA"],"dc:description.sponsorship":["NA"],"dc:description.uri":["http://archive.org/details/reciprocitycalib1094522449"],"dc:format.extent":["64 p. 28 cm."],"dc:identifier.oclc":["ocm227713066"],"dc:identifier.uri":["https://hdl.handle.net/10945/22449"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["Copyright is reserved by the copyright owner","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["NA","Transducer calibration","Reciprocity calibration","In-situ SONAR calibration","Delta-Z method"],"dc:title":["Reciprocity calibration of an underwater transducer using the Delta-Z Method."],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Major, Canadian Forces"],"thesis:degree_discipline":["Engineering Acoustics;Electrical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Engineering Acoustics","M.S. in Electrical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-26T00:20:39Z"}