{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/22502"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/22502","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Strategies in the topological approach to electromagnetic interference control","abstract":"The ability of standard commercial equipment cabinets to be used to provide a barrier to electromagnetic interference is explored. The internal to external, and external to internal, electromagnetic isolation provided by various configurations of cabinet-penetrating conductors was measured at frequencies from 20 HZ to 20 MHZ. Excellent isolation was obtained over the entire frequency range when penetrating conductors (coaxial cables, grounds buses, power conductor green-wires, and power conductor black and white wires) were installed in accord with barrier principles. Little or no isolation was obtained with the direct penetration of the cabinet by conductors. These results were confirmed by laboratory and field measurements (at operating CDAA sites)","abstract_html":"The ability of standard commercial equipment cabinets to be used to provide a barrier to electromagnetic interference is explored. The internal to external, and external to internal, electromagnetic isolation provided by various configurations of cabinet-penetrating conductors was measured at frequencies from 20 HZ to 20 MHZ. Excellent isolation was obtained over the entire frequency range when penetrating conductors (coaxial cables, grounds buses, power conductor green-wires, and power conductor black and white wires) were installed in accord with barrier principles. Little or no isolation was obtained with the direct penetration of the cabinet by conductors. These results were confirmed by laboratory and field measurements (at operating CDAA sites)","abstract_has_math":false,"creators":["Ingram, Vernon D."],"institution":"Monterey, California: U.S. Naval Postgraduate School","degree_name":"M.S. in Electrical Engineering","degree_level":"Masters","degree_discipline":"Electrical Engineering","degree_department":"Electrical and Computer Engineering","school":"Naval Postgraduate School","contributors":[],"advisors":["Jauregui, Stephen"],"committee_chairs":[],"committee_members":["Vincent, Wilbur R."],"year":1987,"date_issued":"1987","date_published":"1987","updated_at":"2026-11-21T23:38:55Z","subjects":["Electrical and computer engineering"],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/22502","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/22502","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F22502","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F22502","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Jauregui, Stephen"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Vincent, Wilbur R."]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.school","label":"School","values":["Naval Postgraduate School"]},{"key":"dc:creator","label":"Author","values":["Ingram, Vernon D."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["December 1987"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-27T00:24:19Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-27T00:24:19Z"]},{"key":"dc:date.issued","label":"Date","values":["1987"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California: U.S. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Electrical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Electromagnetic Interface Control","Electromagnetic Compatability","topological Approach","Grounding","Coaxial Cable Coupling","Green-wire Barrier Plate"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Electrical and computer engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/22502"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Prepared for: Commander Space and Naval Warfare Systems Command, Washington, D.C. 20360"]},{"key":"dc:description.abstract","label":"Abstract","values":["The ability of standard commercial equipment cabinets to be used to provide a barrier to electromagnetic interference is explored. The internal to external, and external to internal, electromagnetic isolation provided by various configurations of cabinet-penetrating conductors was measured at frequencies from 20 HZ to 20 MHZ. Excellent isolation was obtained over the entire frequency range when penetrating conductors (coaxial cables, grounds buses, power conductor green-wires, and power conductor black and white wires) were installed in accord with barrier principles. Little or no isolation was obtained with the direct penetration of the cabinet by conductors. These results were confirmed by laboratory and field measurements (at operating CDAA sites)"]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/strategiesintopo1094522502"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["75 p.: ill. 28 cm."]},{"key":"dc:title","label":"Title","values":["Strategies in the topological approach to electromagnetic interference control"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Jauregui, Stephen"],"dc:contributor.committeemember":["Vincent, Wilbur R."],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.school":["Naval Postgraduate School"],"dc:creator":["Ingram, Vernon D."],"dc:date":["December 1987"],"dc:date.accessioned":["2012-11-27T00:24:19Z"],"dc:date.available":["2012-11-27T00:24:19Z"],"dc:date.issued":["1987"],"dc:description":["Prepared for: Commander Space and Naval Warfare Systems Command, Washington, D.C. 20360"],"dc:description.abstract":["The ability of standard commercial equipment cabinets to be used to provide a barrier to electromagnetic interference is explored. The internal to external, and external to internal, electromagnetic isolation provided by various configurations of cabinet-penetrating conductors was measured at frequencies from 20 HZ to 20 MHZ. Excellent isolation was obtained over the entire frequency range when penetrating conductors (coaxial cables, grounds buses, power conductor green-wires, and power conductor black and white wires) were installed in accord with barrier principles. Little or no isolation was obtained with the direct penetration of the cabinet by conductors. These results were confirmed by laboratory and field measurements (at operating CDAA sites)"],"dc:description.uri":["http://archive.org/details/strategiesintopo1094522502"],"dc:format.extent":["75 p.: ill. 28 cm."],"dc:identifier.uri":["https://hdl.handle.net/10945/22502"],"dc:publisher":["Monterey, California: U.S. Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Electromagnetic Interface Control","Electromagnetic Compatability","topological Approach","Grounding","Coaxial Cable Coupling","Green-wire Barrier Plate"],"dc:subject.lcsh":["Electrical and computer engineering"],"dc:title":["Strategies in the topological approach to electromagnetic interference control"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Electrical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T23:38:55Z"}