{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/22792"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/22792","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Examining the reliability of a hand geometry identity verification device for use in access control","abstract":"Controlling the access to secure government facilities has become increasingly important as these systems are entrusted with more sensitive applications. Unauthorized access could be very detrimental to our nation's security. The use of biometric measures, one of which is hand geometry, may represent a possible solution. This thesis looks at one hand geometry identification device, and determines its effectiveness as a function of the rejection threshold setting, a time lapse in use, and the construction of the reference templates. Rejection thresholds of 40, 60, 80, 100, 120, and 140; three weeks of inactivity by the test subjects; and construction of the reference templates from 1, 2, 4, 5, 6, 8, and 10 individual hand readings were examined. The application of hand geometry identification technology for protecting Command, Control, and Communications (C3) facilities was then discussed. This study used the ID-3D Hand Geometry Identifier built by Recognition Systems, Inc. of San Jose, California. This device was very effective in producing low Type I and Type II error rates during 6300 trials covering all situations examined. This technology has great potential for protecting C3 facilities and systems.","abstract_html":"Controlling the access to secure government facilities has become increasingly important as these systems are entrusted with more sensitive applications. Unauthorized access could be very detrimental to our nation&#x27;s security. The use of biometric measures, one of which is hand geometry, may represent a possible solution. This thesis looks at one hand geometry identification device, and determines its effectiveness as a function of the rejection threshold setting, a time lapse in use, and the construction of the reference templates. Rejection thresholds of 40, 60, 80, 100, 120, and 140; three weeks of inactivity by the test subjects; and construction of the reference templates from 1, 2, 4, 5, 6, 8, and 10 individual hand readings were examined. The application of hand geometry identification technology for protecting Command, Control, and Communications (C3) facilities was then discussed. This study used the ID-3D Hand Geometry Identifier built by Recognition Systems, Inc. of San Jose, California. This device was very effective in producing low Type I and Type II error rates during 6300 trials covering all situations examined. This technology has great potential for protecting C3 facilities and systems.","abstract_has_math":false,"creators":["Bright, Daryl C."],"institution":"Naval Postgraduate School","degree_name":"M.S. in Systems Technology","degree_level":"Masters","degree_discipline":"Systems Technology","degree_department":"Systems Technology","school":"Naval Postgraduate School","contributors":[],"advisors":["Neil, Douglas E."],"committee_chairs":[],"committee_members":["Crumback, Linda"],"year":1987,"date_issued":"1987-03","date_published":"1987-03","updated_at":"2026-11-21T22:49:05Z","subjects":["Command"],"languages":[],"rights":["Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/22792","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/22792","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F22792","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Neil, Douglas E."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Crumback, Linda"]},{"key":"dc:contributor.department","label":"Department","values":["Systems Technology"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School"]},{"key":"dc:contributor.school","label":"School","values":["Naval Postgraduate School"]},{"key":"dc:creator","label":"Author","values":["Bright, Daryl C."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-27T00:28:45Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-27T00:28:45Z"]},{"key":"dc:date.issued","label":"Date","values":["1987-03"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Systems Technology"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Systems Technology"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Biometric","Access Control","Hand Geometry","Security"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Command"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/22792"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Controlling the access to secure government facilities has become increasingly important as these systems are entrusted with more sensitive applications. Unauthorized access could be very detrimental to our nation's security. The use of biometric measures, one of which is hand geometry, may represent a possible solution. This thesis looks at one hand geometry identification device, and determines its effectiveness as a function of the rejection threshold setting, a time lapse in use, and the construction of the reference templates. Rejection thresholds of 40, 60, 80, 100, 120, and 140; three weeks of inactivity by the test subjects; and construction of the reference templates from 1, 2, 4, 5, 6, 8, and 10 individual hand readings were examined. The application of hand geometry identification technology for protecting Command, Control, and Communications (C3) facilities was then discussed. This study used the ID-3D Hand Geometry Identifier built by Recognition Systems, Inc. of San Jose, California. This device was very effective in producing low Type I and Type II error rates during 6300 trials covering all situations examined. This technology has great potential for protecting C3 facilities and systems."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/examiningreliabi1094522792"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["39 p."]},{"key":"dc:title","label":"Title","values":["Examining the reliability of a hand geometry identity verification device for use in access control"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Captain, United States Air Force"]}]}],"canonical_facts":{"dc:contributor.advisor":["Neil, Douglas E."],"dc:contributor.committeemember":["Crumback, Linda"],"dc:contributor.department":["Systems Technology"],"dc:contributor.other":["Naval Postgraduate School"],"dc:contributor.school":["Naval Postgraduate School"],"dc:creator":["Bright, Daryl C."],"dc:date.accessioned":["2012-11-27T00:28:45Z"],"dc:date.available":["2012-11-27T00:28:45Z"],"dc:date.issued":["1987-03"],"dc:description.abstract":["Controlling the access to secure government facilities has become increasingly important as these systems are entrusted with more sensitive applications. Unauthorized access could be very detrimental to our nation's security. The use of biometric measures, one of which is hand geometry, may represent a possible solution. This thesis looks at one hand geometry identification device, and determines its effectiveness as a function of the rejection threshold setting, a time lapse in use, and the construction of the reference templates. Rejection thresholds of 40, 60, 80, 100, 120, and 140; three weeks of inactivity by the test subjects; and construction of the reference templates from 1, 2, 4, 5, 6, 8, and 10 individual hand readings were examined. The application of hand geometry identification technology for protecting Command, Control, and Communications (C3) facilities was then discussed. This study used the ID-3D Hand Geometry Identifier built by Recognition Systems, Inc. of San Jose, California. This device was very effective in producing low Type I and Type II error rates during 6300 trials covering all situations examined. This technology has great potential for protecting C3 facilities and systems."],"dc:description.uri":["http://archive.org/details/examiningreliabi1094522792"],"dc:format.extent":["39 p."],"dc:identifier.uri":["https://hdl.handle.net/10945/22792"],"dc:rights":["Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Biometric","Access Control","Hand Geometry","Security"],"dc:subject.lcsh":["Command"],"dc:title":["Examining the reliability of a hand geometry identity verification device for use in access control"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Captain, United States Air Force"],"thesis:degree_discipline":["Systems Technology"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Systems Technology"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T22:49:05Z"}