{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/23017"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/23017","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Development of design parameters for H-piles in sand using static analysis","abstract":"Design parameters for H-piles in sand are developed using a static analysis approach from the correlation of full scale field load test data. The design parameters obtained are the ultimate pile capacity and the pile's load-settlement characteristics in compression. In establishing these parameters, the effects of residual driving stresses are included. The results indicate that if the area between the pile flanges is assumed to be one-half plugged by the soil, then the ultimate capacity in compression can be estimated by applying the correlations established by Coyle and Castello for full displacement piles. The results also indicate that the pile's load-settlement characteristics can be approximated by again assuming the flange area to be one-half plugged and modeling the pile-soil system on the axially loaded pile computer program known as APILE. The accuracy of these design parameters are evaluated by comparing the measured ultimate capacity and load-settlement curves of two field tested H-piles to the predicted results. Keywords: Pile structures; Compressive properties; Cohesionless soils; Tensile properties; Side friction loads. Theses. (edc)","abstract_html":"Design parameters for H-piles in sand are developed using a static analysis approach from the correlation of full scale field load test data. The design parameters obtained are the ultimate pile capacity and the pile&#x27;s load-settlement characteristics in compression. In establishing these parameters, the effects of residual driving stresses are included. The results indicate that if the area between the pile flanges is assumed to be one-half plugged by the soil, then the ultimate capacity in compression can be estimated by applying the correlations established by Coyle and Castello for full displacement piles. The results also indicate that the pile&#x27;s load-settlement characteristics can be approximated by again assuming the flange area to be one-half plugged and modeling the pile-soil system on the axially loaded pile computer program known as APILE. The accuracy of these design parameters are evaluated by comparing the measured ultimate capacity and load-settlement curves of two field tested H-piles to the predicted results. Keywords: Pile structures; Compressive properties; Cohesionless soils; Tensile properties; Side friction loads. Theses. (edc)","abstract_has_math":false,"creators":["Ungaro, Ronald"],"institution":"Texas A&M University","degree_name":"Master of Engineering","degree_level":null,"degree_discipline":"Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1988,"date_issued":"1988","date_published":"1988","updated_at":"2026-11-19T06:24:34Z","subjects":["Naval architecture"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["ocm82773615"],"render_values":[{"text":"ocm82773615","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/23017","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/23017","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F23017","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F23017","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Ungaro, Ronald"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-27T18:06:48Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-27T18:06:48Z"]},{"key":"dc:date.issued","label":"Date","values":["1988"]},{"key":"dc:publisher","label":"Institution","values":["Texas A&M University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Texas A&M University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Naval architecture"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["ocm82773615"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/23017"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Design parameters for H-piles in sand are developed using a static analysis approach from the correlation of full scale field load test data. The design parameters obtained are the ultimate pile capacity and the pile's load-settlement characteristics in compression. In establishing these parameters, the effects of residual driving stresses are included. The results indicate that if the area between the pile flanges is assumed to be one-half plugged by the soil, then the ultimate capacity in compression can be estimated by applying the correlations established by Coyle and Castello for full displacement piles. The results also indicate that the pile's load-settlement characteristics can be approximated by again assuming the flange area to be one-half plugged and modeling the pile-soil system on the axially loaded pile computer program known as APILE. The accuracy of these design parameters are evaluated by comparing the measured ultimate capacity and load-settlement curves of two field tested H-piles to the predicted results. Keywords: Pile structures; Compressive properties; Cohesionless soils; Tensile properties; Side friction loads. Theses. (edc)"]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/developmentofdes1094523017"]},{"key":"dc:title","label":"Title","values":["Development of design parameters for H-piles in sand using static analysis"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:creator":["Ungaro, Ronald"],"dc:date.accessioned":["2012-11-27T18:06:48Z"],"dc:date.available":["2012-11-27T18:06:48Z"],"dc:date.issued":["1988"],"dc:description.abstract":["Design parameters for H-piles in sand are developed using a static analysis approach from the correlation of full scale field load test data. The design parameters obtained are the ultimate pile capacity and the pile's load-settlement characteristics in compression. In establishing these parameters, the effects of residual driving stresses are included. The results indicate that if the area between the pile flanges is assumed to be one-half plugged by the soil, then the ultimate capacity in compression can be estimated by applying the correlations established by Coyle and Castello for full displacement piles. The results also indicate that the pile's load-settlement characteristics can be approximated by again assuming the flange area to be one-half plugged and modeling the pile-soil system on the axially loaded pile computer program known as APILE. The accuracy of these design parameters are evaluated by comparing the measured ultimate capacity and load-settlement curves of two field tested H-piles to the predicted results. Keywords: Pile structures; Compressive properties; Cohesionless soils; Tensile properties; Side friction loads. Theses. (edc)"],"dc:description.uri":["http://archive.org/details/developmentofdes1094523017"],"dc:identifier.oclc":["ocm82773615"],"dc:identifier.uri":["https://hdl.handle.net/10945/23017"],"dc:publisher":["Texas A&M University"],"dc:subject.lcsh":["Naval architecture"],"dc:title":["Development of design parameters for H-piles in sand using static analysis"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_discipline":["Engineering"],"thesis:degree_name":["Master of Engineering"],"thesis:institution_name":["Texas A&M University"]},"updated_at":"2026-11-19T06:24:34Z"}