{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/23254"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/23254","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Hot-wire measurements of compressor blade wakes in a cascade wind tunnel","abstract":"A hot-wire system, with software designed for calibrating and taking data with single, double and triple hot-wire sensors separately, or three probes at once, was verified and used to make wake measurements downstream of a compressor stator blade in a cascade wind tunnel. Using a single hot-wire probe, velocity and turbulence data were obtained in the wake of the controlled-diffusion blade in order to verify LDV data taken in earlier studies. The tests were conducted at three inlet angles from near design incidence towards the expected stall condition at a Mach number of 0.25 and Reynolds number of about 700,000. Wake profiles were obtained from 0.08 to 0.2 chord lengths downstream of the blade. Good agreement was found with LDV measurements. Measurements at the highest incidence angle showed that the wake constituted one third of the flow and yet no separation occurred before the trailing edge on the suction side of the blade. Keywords: Laser doppler velocimeters","abstract_html":"A hot-wire system, with software designed for calibrating and taking data with single, double and triple hot-wire sensors separately, or three probes at once, was verified and used to make wake measurements downstream of a compressor stator blade in a cascade wind tunnel. Using a single hot-wire probe, velocity and turbulence data were obtained in the wake of the controlled-diffusion blade in order to verify LDV data taken in earlier studies. The tests were conducted at three inlet angles from near design incidence towards the expected stall condition at a Mach number of 0.25 and Reynolds number of about 700,000. Wake profiles were obtained from 0.08 to 0.2 chord lengths downstream of the blade. Good agreement was found with LDV measurements. Measurements at the highest incidence angle showed that the wake constituted one third of the flow and yet no separation occurred before the trailing edge on the suction side of the blade. Keywords: Laser doppler velocimeters","abstract_has_math":false,"creators":["Baydar, Adem."],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Aeronautical Engineering","degree_level":"Masters","degree_discipline":"Aeronautical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Shreeve, Raymond P."],"committee_chairs":[],"committee_members":[],"year":1988,"date_issued":"1988-03","date_published":"1988-03","updated_at":"2026-11-21T23:42:51Z","subjects":["Aeronautics"],"languages":[],"rights":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/23254","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/23254","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F23254","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F23254","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Shreeve, Raymond P."]},{"key":"dc:creator","label":"Author","values":["Baydar, Adem."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-27T18:17:44Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-27T18:17:44Z"]},{"key":"dc:date.issued","label":"Date","values":["1988-03"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Aeronautical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Aeronautical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["thesis","word processing","Script","GML","text processing"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Aeronautics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/23254"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A hot-wire system, with software designed for calibrating and taking data with single, double and triple hot-wire sensors separately, or three probes at once, was verified and used to make wake measurements downstream of a compressor stator blade in a cascade wind tunnel. Using a single hot-wire probe, velocity and turbulence data were obtained in the wake of the controlled-diffusion blade in order to verify LDV data taken in earlier studies. The tests were conducted at three inlet angles from near design incidence towards the expected stall condition at a Mach number of 0.25 and Reynolds number of about 700,000. Wake profiles were obtained from 0.08 to 0.2 chord lengths downstream of the blade. Good agreement was found with LDV measurements. Measurements at the highest incidence angle showed that the wake constituted one third of the flow and yet no separation occurred before the trailing edge on the suction side of the blade. Keywords: Laser doppler velocimeters"]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/hotwiremeasureme1094523254"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["ix, 47 p."]},{"key":"dc:title","label":"Title","values":["Hot-wire measurements of compressor blade wakes in a cascade wind tunnel"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant,Turkish Air Force"]}]}],"canonical_facts":{"dc:contributor.advisor":["Shreeve, Raymond P."],"dc:creator":["Baydar, Adem."],"dc:date.accessioned":["2012-11-27T18:17:44Z"],"dc:date.available":["2012-11-27T18:17:44Z"],"dc:date.issued":["1988-03"],"dc:description.abstract":["A hot-wire system, with software designed for calibrating and taking data with single, double and triple hot-wire sensors separately, or three probes at once, was verified and used to make wake measurements downstream of a compressor stator blade in a cascade wind tunnel. Using a single hot-wire probe, velocity and turbulence data were obtained in the wake of the controlled-diffusion blade in order to verify LDV data taken in earlier studies. The tests were conducted at three inlet angles from near design incidence towards the expected stall condition at a Mach number of 0.25 and Reynolds number of about 700,000. Wake profiles were obtained from 0.08 to 0.2 chord lengths downstream of the blade. Good agreement was found with LDV measurements. Measurements at the highest incidence angle showed that the wake constituted one third of the flow and yet no separation occurred before the trailing edge on the suction side of the blade. Keywords: Laser doppler velocimeters"],"dc:description.uri":["http://archive.org/details/hotwiremeasureme1094523254"],"dc:format.extent":["ix, 47 p."],"dc:identifier.uri":["https://hdl.handle.net/10945/23254"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["thesis","word processing","Script","GML","text processing"],"dc:subject.lcsh":["Aeronautics"],"dc:title":["Hot-wire measurements of compressor blade wakes in a cascade wind tunnel"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant,Turkish Air Force"],"thesis:degree_discipline":["Aeronautical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Aeronautical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T23:42:51Z"}