{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/23668"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/23668","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Experimental development of tubseide heat transfer correlations for laminar flow with and without inserts.","abstract":"An experimental study of laminar flow heat transfer of an ethylene glycol/water mixture in an electrically heated horizontal tube using wire mesh (HEATEX) and twisted tape inserts was investigated. Twelve thermocouples, inserted in the tube wall at four longitudinal locations, enabled a mean inside experimental heat-transfer coefficient to be accurately measured. A constant wall heat flux boundary condition was placed on the wall by wrapping six 200 W flexible heater tapes tightly around the tube. The ethylene glycol/water mixture provided a coolant Reynolds number between 200-5000 and a Prandtl number between 30-140. Two smooth inside diameters and a roped tube profile were tested with and without the inserts. Heattransfer correlations for tubes without inserts were developed and compared with theory for both thermally and hydrodynamically developing flow. Correlations were also developed for the two types of inserts.","abstract_html":"An experimental study of laminar flow heat transfer of an ethylene glycol/water mixture in an electrically heated horizontal tube using wire mesh (HEATEX) and twisted tape inserts was investigated. Twelve thermocouples, inserted in the tube wall at four longitudinal locations, enabled a mean inside experimental heat-transfer coefficient to be accurately measured. A constant wall heat flux boundary condition was placed on the wall by wrapping six 200 W flexible heater tapes tightly around the tube. The ethylene glycol/water mixture provided a coolant Reynolds number between 200-5000 and a Prandtl number between 30-140. Two smooth inside diameters and a roped tube profile were tested with and without the inserts. Heattransfer correlations for tubes without inserts were developed and compared with theory for both thermally and hydrodynamically developing flow. Correlations were also developed for the two types of inserts.","abstract_has_math":false,"creators":["Guido, Joseph D."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S. in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":"Naval Postgraduate School","contributors":[],"advisors":["Marto, P.J.","Memory, Stephen B."],"committee_chairs":[],"committee_members":[],"year":1992,"date_issued":"1992-09","date_published":"1992-09","updated_at":"2026-11-26T00:19:59Z","subjects":[],"languages":[],"rights":["Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/23668","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/23668","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F23668","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F23668","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Marto, P.J.","Memory, Stephen B."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School"]},{"key":"dc:contributor.school","label":"School","values":["Naval Postgraduate School"]},{"key":"dc:creator","label":"Author","values":["Guido, Joseph D."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-29T16:14:32Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-29T16:14:32Z"]},{"key":"dc:date.issued","label":"Date","values":["1992-09"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Laminar Flow","Tubeside Heat Transfer","Twisted Tape and HEATEX Inserts"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/23668"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An experimental study of laminar flow heat transfer of an ethylene glycol/water mixture in an electrically heated horizontal tube using wire mesh (HEATEX) and twisted tape inserts was investigated. Twelve thermocouples, inserted in the tube wall at four longitudinal locations, enabled a mean inside experimental heat-transfer coefficient to be accurately measured. A constant wall heat flux boundary condition was placed on the wall by wrapping six 200 W flexible heater tapes tightly around the tube. The ethylene glycol/water mixture provided a coolant Reynolds number between 200-5000 and a Prandtl number between 30-140. Two smooth inside diameters and a roped tube profile were tested with and without the inserts. Heattransfer correlations for tubes without inserts were developed and compared with theory for both thermally and hydrodynamically developing flow. Correlations were also developed for the two types of inserts."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/experimentaldeve1094523668"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["160 p.;28 cm."]},{"key":"dc:title","label":"Title","values":["Experimental development of tubseide heat transfer correlations for laminar flow with and without inserts."]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant Commander, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Marto, P.J.","Memory, Stephen B."],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["Naval Postgraduate School"],"dc:contributor.school":["Naval Postgraduate School"],"dc:creator":["Guido, Joseph D."],"dc:date.accessioned":["2012-11-29T16:14:32Z"],"dc:date.available":["2012-11-29T16:14:32Z"],"dc:date.issued":["1992-09"],"dc:description.abstract":["An experimental study of laminar flow heat transfer of an ethylene glycol/water mixture in an electrically heated horizontal tube using wire mesh (HEATEX) and twisted tape inserts was investigated. Twelve thermocouples, inserted in the tube wall at four longitudinal locations, enabled a mean inside experimental heat-transfer coefficient to be accurately measured. A constant wall heat flux boundary condition was placed on the wall by wrapping six 200 W flexible heater tapes tightly around the tube. The ethylene glycol/water mixture provided a coolant Reynolds number between 200-5000 and a Prandtl number between 30-140. Two smooth inside diameters and a roped tube profile were tested with and without the inserts. Heattransfer correlations for tubes without inserts were developed and compared with theory for both thermally and hydrodynamically developing flow. Correlations were also developed for the two types of inserts."],"dc:description.uri":["http://archive.org/details/experimentaldeve1094523668"],"dc:format.extent":["160 p.;28 cm."],"dc:identifier.uri":["https://hdl.handle.net/10945/23668"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Laminar Flow","Tubeside Heat Transfer","Twisted Tape and HEATEX Inserts"],"dc:title":["Experimental development of tubseide heat transfer correlations for laminar flow with and without inserts."],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant Commander, United States Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-26T00:19:59Z"}