{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/23876"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/23876","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Emissivity of rocket plume particulates.","abstract":"The optical properties of motor aluminum oxide are required inputs to current plume signature prediction codes, such as SIRRM. Accurate predictions are possible only if variations in the particle emissivity due to changes in particle size, contamination, and changing temperature, etc. , are known . This investigation demonstrated a simplified method for determination of the emissivity of rocket motor generated alumina. Plume particulate material was collected on tungsten alloy wire during motor firings. A DC circuit was used to resistively heat the material, and the temperature was determined at various points by relating the wire resistivity to circuit current and voltage. An Agema Thermovision infrared (3.5-5 (j.) camera and microscope were used to observe the material during heating, and broad-band emissivity was computed using system software. It was estimated that the emissivity could be measured with an accuracy of ± 3%. Motor alumina was found to have significantly greater emissivity than pure alumina in the temperature range of 500-1200K.","abstract_html":"The optical properties of motor aluminum oxide are required inputs to current plume signature prediction codes, such as SIRRM. Accurate predictions are possible only if variations in the particle emissivity due to changes in particle size, contamination, and changing temperature, etc. , are known . This investigation demonstrated a simplified method for determination of the emissivity of rocket motor generated alumina. Plume particulate material was collected on tungsten alloy wire during motor firings. A DC circuit was used to resistively heat the material, and the temperature was determined at various points by relating the wire resistivity to circuit current and voltage. An Agema Thermovision infrared (3.5-5 (j.) camera and microscope were used to observe the material during heating, and broad-band emissivity was computed using system software. It was estimated that the emissivity could be measured with an accuracy of ± 3%. Motor alumina was found to have significantly greater emissivity than pure alumina in the temperature range of 500-1200K.","abstract_has_math":false,"creators":["Whisman, Curtis D."],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Astronautical Engineering","degree_level":"Masters","degree_discipline":"Astronautical Engineering","degree_department":"Astronautical Engineering","school":"Naval Postgraduate School","contributors":[],"advisors":["Netzer, David W."],"committee_chairs":[],"committee_members":["Hobson, Garth"],"year":1992,"date_issued":"1992-09","date_published":"1992-09","updated_at":"2026-11-20T22:20:29Z","subjects":[],"languages":[],"rights":["Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/23876","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/23876","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F23876","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F23876","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Netzer, David W."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Hobson, Garth"]},{"key":"dc:contributor.department","label":"Department","values":["Astronautical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School"]},{"key":"dc:contributor.school","label":"School","values":["Naval Postgraduate School"]},{"key":"dc:creator","label":"Author","values":["Whisman, Curtis D."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-29T16:18:05Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-29T16:18:05Z"]},{"key":"dc:date.issued","label":"Date","values":["1992-09"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Astronautical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Astronautical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Solid-Propellant","Rocket Motor","Alumina","Emissivity"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/23876"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The optical properties of motor aluminum oxide are required inputs to current plume signature prediction codes, such as SIRRM. Accurate predictions are possible only if variations in the particle emissivity due to changes in particle size, contamination, and changing temperature, etc. , are known . This investigation demonstrated a simplified method for determination of the emissivity of rocket motor generated alumina. Plume particulate material was collected on tungsten alloy wire during motor firings. A DC circuit was used to resistively heat the material, and the temperature was determined at various points by relating the wire resistivity to circuit current and voltage. An Agema Thermovision infrared (3.5-5 (j.) camera and microscope were used to observe the material during heating, and broad-band emissivity was computed using system software. It was estimated that the emissivity could be measured with an accuracy of ± 3%. Motor alumina was found to have significantly greater emissivity than pure alumina in the temperature range of 500-1200K."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/emissivityofrock1094523876"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["38 p.;28 cm."]},{"key":"dc:title","label":"Title","values":["Emissivity of rocket plume particulates."]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Netzer, David W."],"dc:contributor.committeemember":["Hobson, Garth"],"dc:contributor.department":["Astronautical Engineering"],"dc:contributor.other":["Naval Postgraduate School"],"dc:contributor.school":["Naval Postgraduate School"],"dc:creator":["Whisman, Curtis D."],"dc:date.accessioned":["2012-11-29T16:18:05Z"],"dc:date.available":["2012-11-29T16:18:05Z"],"dc:date.issued":["1992-09"],"dc:description.abstract":["The optical properties of motor aluminum oxide are required inputs to current plume signature prediction codes, such as SIRRM. Accurate predictions are possible only if variations in the particle emissivity due to changes in particle size, contamination, and changing temperature, etc. , are known . This investigation demonstrated a simplified method for determination of the emissivity of rocket motor generated alumina. Plume particulate material was collected on tungsten alloy wire during motor firings. A DC circuit was used to resistively heat the material, and the temperature was determined at various points by relating the wire resistivity to circuit current and voltage. An Agema Thermovision infrared (3.5-5 (j.) camera and microscope were used to observe the material during heating, and broad-band emissivity was computed using system software. It was estimated that the emissivity could be measured with an accuracy of ± 3%. Motor alumina was found to have significantly greater emissivity than pure alumina in the temperature range of 500-1200K."],"dc:description.uri":["http://archive.org/details/emissivityofrock1094523876"],"dc:format.extent":["38 p.;28 cm."],"dc:identifier.uri":["https://hdl.handle.net/10945/23876"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Solid-Propellant","Rocket Motor","Alumina","Emissivity"],"dc:title":["Emissivity of rocket plume particulates."],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Astronautical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Astronautical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-20T22:20:29Z"}