{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/2409"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/2409","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Vibration analysis using a MEMS accelerometer","abstract":"The primary objective of this these was to study the feasibility of using a MEMS accelerometer to monitor vibration signatures of a machine to determine if the machine is operating properly. The secondary objective was to investigate the self test features of the accelerometer used in the vibration monitoring. An Efector Octavis accelerometer sensor was used in this study. It was used to monitor a small air pump and an air conditioning (AC) system. The sensor provided the amplitude for the frequency spectrum of the motor vibration. A reference signal was calculated by taking an average of the spectrum over 30 seconds. Two methods (a ratio of cross-correlation coefficients and a spectral distance) were used to compare the reference to the sensor data. The spectral distance method proved to be the better of the two. Using this method, the system could sense when the pump or the AC unit were malfunctioning. The self test feature involved exciting the Built in Self Test (BIST) pin of the accelerometer with a signal generator. Then the impulse response of the accelerometer was measured from the output pin using an oscilloscope.","abstract_html":"The primary objective of this these was to study the feasibility of using a MEMS accelerometer to monitor vibration signatures of a machine to determine if the machine is operating properly. The secondary objective was to investigate the self test features of the accelerometer used in the vibration monitoring. An Efector Octavis accelerometer sensor was used in this study. It was used to monitor a small air pump and an air conditioning (AC) system. The sensor provided the amplitude for the frequency spectrum of the motor vibration. A reference signal was calculated by taking an average of the spectrum over 30 seconds. Two methods (a ratio of cross-correlation coefficients and a spectral distance) were used to compare the reference to the sensor data. The spectral distance method proved to be the better of the two. Using this method, the system could sense when the pump or the AC unit were malfunctioning. The self test feature involved exciting the Built in Self Test (BIST) pin of the accelerometer with a signal generator. Then the impulse response of the accelerometer was measured from the output pin using an oscilloscope.","abstract_has_math":false,"creators":["Young, Jonathan C."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S.","degree_level":"Masters","degree_discipline":"Electrical Engineering","degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Yun, Xiaoping"],"committee_chairs":[],"committee_members":["Cristi, Roberto."],"year":2006,"date_issued":"2006-12","date_published":"2006-12","updated_at":"2026-11-19T06:26:20Z","subjects":["Electrical engineering"],"languages":[],"rights":["Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["80947277"],"render_values":[{"text":"80947277","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/2409","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/2409","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F2409","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Yun, Xiaoping"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Cristi, Roberto."]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Young, Jonathan C."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-03-14T17:35:06Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-03-14T17:35:06Z"]},{"key":"dc:date.issued","label":"Date","values":["2006-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Electrical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["80947277"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/2409"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The primary objective of this these was to study the feasibility of using a MEMS accelerometer to monitor vibration signatures of a machine to determine if the machine is operating properly. The secondary objective was to investigate the self test features of the accelerometer used in the vibration monitoring. An Efector Octavis accelerometer sensor was used in this study. It was used to monitor a small air pump and an air conditioning (AC) system. The sensor provided the amplitude for the frequency spectrum of the motor vibration. A reference signal was calculated by taking an average of the spectrum over 30 seconds. Two methods (a ratio of cross-correlation coefficients and a spectral distance) were used to compare the reference to the sensor data. The spectral distance method proved to be the better of the two. Using this method, the system could sense when the pump or the AC unit were malfunctioning. The self test feature involved exciting the Built in Self Test (BIST) pin of the accelerometer with a signal generator. Then the impulse response of the accelerometer was measured from the output pin using an oscilloscope."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/vibrationnalysis109452409"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xviii, 41 p. : ill. ;"]},{"key":"dc:title","label":"Title","values":["Vibration analysis using a MEMS accelerometer"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:etd.verified","label":"Local Etd Verified","values":["no"]}]}],"canonical_facts":{"dc:contributor.advisor":["Yun, Xiaoping"],"dc:contributor.committeemember":["Cristi, Roberto."],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Young, Jonathan C."],"dc:date.accessioned":["2012-03-14T17:35:06Z"],"dc:date.available":["2012-03-14T17:35:06Z"],"dc:date.issued":["2006-12"],"dc:description.abstract":["The primary objective of this these was to study the feasibility of using a MEMS accelerometer to monitor vibration signatures of a machine to determine if the machine is operating properly. The secondary objective was to investigate the self test features of the accelerometer used in the vibration monitoring. An Efector Octavis accelerometer sensor was used in this study. It was used to monitor a small air pump and an air conditioning (AC) system. The sensor provided the amplitude for the frequency spectrum of the motor vibration. A reference signal was calculated by taking an average of the spectrum over 30 seconds. Two methods (a ratio of cross-correlation coefficients and a spectral distance) were used to compare the reference to the sensor data. The spectral distance method proved to be the better of the two. Using this method, the system could sense when the pump or the AC unit were malfunctioning. The self test feature involved exciting the Built in Self Test (BIST) pin of the accelerometer with a signal generator. Then the impulse response of the accelerometer was measured from the output pin using an oscilloscope."],"dc:description.uri":["http://archive.org/details/vibrationnalysis109452409"],"dc:format.extent":["xviii, 41 p. : ill. ;"],"dc:identifier.oclc":["80947277"],"dc:identifier.uri":["https://hdl.handle.net/10945/2409"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["Approved for public release; distribution is unlimited."],"dc:subject.lcsh":["Electrical engineering"],"dc:title":["Vibration analysis using a MEMS accelerometer"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:etd.verified":["no"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S."],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:26:20Z"}