{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/24217"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/24217","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Preliminary design of a water cooled avionics rack","abstract":"Military electronics are frequently operated in excessively confined spaces aboard ships and aircraft. This limited space impacts significantly on the space available for cooling equipment. The optimal solution is the development of one universal, modular rack for shipboard or aviation use. with a modular design, upgrades to equipment could also be accompanied by an upgrade to the cooling rack itself with very little additional cost or difficulty. A water cooled avionics rack can provide sufficient cooling for any piece or combination of avionics equipment if enough water flow paths are used, the water is at the appropriated temperature and the water is properly distributed within the passages. To determine if the cooling medium , water, is sufficiently distributed within a modular cooling rack, an analysis of the flow and pressure distribution of the coolant is required. This thesis presents a computer code that has been developed as an initial step in the total design of a modular cooling rack for avionics equipment. It itself, the code details a specific design technique and allows for the determination of whether a proposed configuration, including source location, characteristics of the cooling water, and the size and shape of the proposed flow passages will indeed provide a proper distribution of the coolant.","abstract_html":"Military electronics are frequently operated in excessively confined spaces aboard ships and aircraft. This limited space impacts significantly on the space available for cooling equipment. The optimal solution is the development of one universal, modular rack for shipboard or aviation use. with a modular design, upgrades to equipment could also be accompanied by an upgrade to the cooling rack itself with very little additional cost or difficulty. A water cooled avionics rack can provide sufficient cooling for any piece or combination of avionics equipment if enough water flow paths are used, the water is at the appropriated temperature and the water is properly distributed within the passages. To determine if the cooling medium , water, is sufficiently distributed within a modular cooling rack, an analysis of the flow and pressure distribution of the coolant is required. This thesis presents a computer code that has been developed as an initial step in the total design of a modular cooling rack for avionics equipment. It itself, the code details a specific design technique and allows for the determination of whether a proposed configuration, including source location, characteristics of the cooling water, and the size and shape of the proposed flow passages will indeed provide a proper distribution of the coolant.","abstract_has_math":false,"creators":["Ellis, Colleen Laverna","Kraus, Allan D."],"institution":"Monterey, California: Naval Postgraduate School","degree_name":"M.S. in Aeronautical Engineering","degree_level":"Masters","degree_discipline":"Aeronautical Engineering","degree_department":"Department of Aeronautics and Astronautics","school":null,"contributors":[],"advisors":["Kraus, Allan D."],"committee_chairs":[],"committee_members":[],"year":1993,"date_issued":"1993-03","date_published":"1993-03","updated_at":"2026-11-21T23:34:25Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/24217","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/24217","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F24217","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F24217","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Kraus, Allan D."]},{"key":"dc:contributor.department","label":"Department","values":["Department of Aeronautics and Astronautics"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Ellis, Colleen Laverna","Kraus, Allan D."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["March 1993"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-29T16:21:23Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-29T16:21:23Z"]},{"key":"dc:date.issued","label":"Date","values":["1993-03"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California: Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Aeronautical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Aeronautical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Avionics","Cooling rack","Water cooled avionics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/24217"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Military electronics are frequently operated in excessively confined spaces aboard ships and aircraft. This limited space impacts significantly on the space available for cooling equipment. The optimal solution is the development of one universal, modular rack for shipboard or aviation use. with a modular design, upgrades to equipment could also be accompanied by an upgrade to the cooling rack itself with very little additional cost or difficulty. A water cooled avionics rack can provide sufficient cooling for any piece or combination of avionics equipment if enough water flow paths are used, the water is at the appropriated temperature and the water is properly distributed within the passages. To determine if the cooling medium , water, is sufficiently distributed within a modular cooling rack, an analysis of the flow and pressure distribution of the coolant is required. This thesis presents a computer code that has been developed as an initial step in the total design of a modular cooling rack for avionics equipment. It itself, the code details a specific design technique and allows for the determination of whether a proposed configuration, including source location, characteristics of the cooling water, and the size and shape of the proposed flow passages will indeed provide a proper distribution of the coolant."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/preliminarydesig1094524217"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["40 p."]},{"key":"dc:title","label":"Title","values":["Preliminary design of a water cooled avionics rack"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant Commander, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Kraus, Allan D."],"dc:contributor.department":["Department of Aeronautics and Astronautics"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Ellis, Colleen Laverna","Kraus, Allan D."],"dc:date":["March 1993"],"dc:date.accessioned":["2012-11-29T16:21:23Z"],"dc:date.available":["2012-11-29T16:21:23Z"],"dc:date.issued":["1993-03"],"dc:description.abstract":["Military electronics are frequently operated in excessively confined spaces aboard ships and aircraft. This limited space impacts significantly on the space available for cooling equipment. The optimal solution is the development of one universal, modular rack for shipboard or aviation use. with a modular design, upgrades to equipment could also be accompanied by an upgrade to the cooling rack itself with very little additional cost or difficulty. A water cooled avionics rack can provide sufficient cooling for any piece or combination of avionics equipment if enough water flow paths are used, the water is at the appropriated temperature and the water is properly distributed within the passages. To determine if the cooling medium , water, is sufficiently distributed within a modular cooling rack, an analysis of the flow and pressure distribution of the coolant is required. This thesis presents a computer code that has been developed as an initial step in the total design of a modular cooling rack for avionics equipment. It itself, the code details a specific design technique and allows for the determination of whether a proposed configuration, including source location, characteristics of the cooling water, and the size and shape of the proposed flow passages will indeed provide a proper distribution of the coolant."],"dc:description.uri":["http://archive.org/details/preliminarydesig1094524217"],"dc:format.extent":["40 p."],"dc:identifier.uri":["https://hdl.handle.net/10945/24217"],"dc:publisher":["Monterey, California: Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Avionics","Cooling rack","Water cooled avionics"],"dc:title":["Preliminary design of a water cooled avionics rack"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant Commander, United States Navy"],"thesis:degree_discipline":["Aeronautical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Aeronautical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T23:34:25Z"}