{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/24344"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/24344","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Optical tomography of the ZaP flow Z-pinch plasma","abstract":"The ZaP Flow Z-Pinch Experiment forms a Z-pinch with an embedded axial flow that exhibits stability for 500 - 2000 times the instabililty growth time for a static Z-pinch. Two linear photodiode arrays placed orthogonal to each other measure chord-integrated emissivity of the plasma. Deconvolving these data produce time resolved 1-D and 2-D emission profiles of the Z-pinch cross-section during the stable quiescent period. These unfiltered emission profiles show that the pinch has a radius of approximately 1 cm. Filtering the light for H(alpha) emission shows a defined hollow profile 1 cm in radius. Bremsstrahlung filtered light exhibits a peaked profile during periods of high intensity emissivity and a hollow profile at lower intensities. Additional measurements from an Imacon camera, interferometer, and azimuthal arrays of magnetic probes determine the spatial correlation between plasma emissivity, plasma density, and plasma current. The tomographic information collected by the photodiode arrays increases understanding of flow stabilization theory and Z-pinch configuration plasmas.","abstract_html":"The ZaP Flow Z-Pinch Experiment forms a Z-pinch with an embedded axial flow that exhibits stability for 500 - 2000 times the instabililty growth time for a static Z-pinch. Two linear photodiode arrays placed orthogonal to each other measure chord-integrated emissivity of the plasma. Deconvolving these data produce time resolved 1-D and 2-D emission profiles of the Z-pinch cross-section during the stable quiescent period. These unfiltered emission profiles show that the pinch has a radius of approximately 1 cm. Filtering the light for H(alpha) emission shows a defined hollow profile 1 cm in radius. Bremsstrahlung filtered light exhibits a peaked profile during periods of high intensity emissivity and a hollow profile at lower intensities. Additional measurements from an Imacon camera, interferometer, and azimuthal arrays of magnetic probes determine the spatial correlation between plasma emissivity, plasma density, and plasma current. The tomographic information collected by the photodiode arrays increases understanding of flow stabilization theory and Z-pinch configuration plasmas.","abstract_has_math":false,"creators":["Madson, Adam M."],"institution":"University of Washington","degree_name":"Master of Science in Aeronautics and Astronautics","degree_level":"Masters","degree_discipline":"Aeronautics and Astronautics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005-05","date_published":"2005-05","updated_at":"2026-11-19T06:26:20Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Distribution Statement A. Approved for public release: Distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/24344","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/24344","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F24344","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["CIVINS (Civilian Institutions)"]},{"key":"dc:creator","label":"Author","values":["Madson, Adam M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-12-13T18:44:03Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-12-13T18:44:03Z"]},{"key":"dc:date.issued","label":"Date","values":["2005-05"]},{"key":"dc:publisher","label":"Institution","values":["University of Washington"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["CIVINS (Civilian Institutions) Theses and Dissertations"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c6eb8929-c883-4d31-84f5-166ce3ae8c52"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["0855bc76-cf0d-4c5f-84ba-3b1c54b01904"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Aeronautics and Astronautics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Aeronautics and Astronautics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Washington"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Distribution Statement A. Approved for public release: Distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/24344"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The ZaP Flow Z-Pinch Experiment forms a Z-pinch with an embedded axial flow that exhibits stability for 500 - 2000 times the instabililty growth time for a static Z-pinch. Two linear photodiode arrays placed orthogonal to each other measure chord-integrated emissivity of the plasma. Deconvolving these data produce time resolved 1-D and 2-D emission profiles of the Z-pinch cross-section during the stable quiescent period. These unfiltered emission profiles show that the pinch has a radius of approximately 1 cm. Filtering the light for H(alpha) emission shows a defined hollow profile 1 cm in radius. Bremsstrahlung filtered light exhibits a peaked profile during periods of high intensity emissivity and a hollow profile at lower intensities. Additional measurements from an Imacon camera, interferometer, and azimuthal arrays of magnetic probes determine the spatial correlation between plasma emissivity, plasma density, and plasma current. The tomographic information collected by the photodiode arrays increases understanding of flow stabilization theory and Z-pinch configuration plasmas."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/opticaltomograph1094524344"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["154 p."]},{"key":"dc:title","label":"Title","values":["Optical tomography of the ZaP flow Z-pinch plasma"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.other":["CIVINS (Civilian Institutions)"],"dc:creator":["Madson, Adam M."],"dc:date.accessioned":["2012-12-13T18:44:03Z"],"dc:date.available":["2012-12-13T18:44:03Z"],"dc:date.issued":["2005-05"],"dc:description.abstract":["The ZaP Flow Z-Pinch Experiment forms a Z-pinch with an embedded axial flow that exhibits stability for 500 - 2000 times the instabililty growth time for a static Z-pinch. Two linear photodiode arrays placed orthogonal to each other measure chord-integrated emissivity of the plasma. Deconvolving these data produce time resolved 1-D and 2-D emission profiles of the Z-pinch cross-section during the stable quiescent period. These unfiltered emission profiles show that the pinch has a radius of approximately 1 cm. Filtering the light for H(alpha) emission shows a defined hollow profile 1 cm in radius. Bremsstrahlung filtered light exhibits a peaked profile during periods of high intensity emissivity and a hollow profile at lower intensities. Additional measurements from an Imacon camera, interferometer, and azimuthal arrays of magnetic probes determine the spatial correlation between plasma emissivity, plasma density, and plasma current. The tomographic information collected by the photodiode arrays increases understanding of flow stabilization theory and Z-pinch configuration plasmas."],"dc:description.uri":["http://archive.org/details/opticaltomograph1094524344"],"dc:format.extent":["154 p."],"dc:identifier.uri":["https://hdl.handle.net/10945/24344"],"dc:publisher":["University of Washington"],"dc:relation.ispartofseries":["CIVINS (Civilian Institutions) Theses and Dissertations"],"dc:relation.orgunit":["c6eb8929-c883-4d31-84f5-166ce3ae8c52"],"dc:relation.seriesentity":["0855bc76-cf0d-4c5f-84ba-3b1c54b01904"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Distribution Statement A. Approved for public release: Distribution is unlimited."],"dc:title":["Optical tomography of the ZaP flow Z-pinch plasma"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_discipline":["Aeronautics and Astronautics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Aeronautics and Astronautics"],"thesis:institution_name":["University of Washington"]},"updated_at":"2026-11-19T06:26:20Z"}