{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/24364"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/24364","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Onset of flow instability and critical heat flux in horizontal, thin, uniformly- heated annuli","abstract":"Two-phase flow instability (Ledinegg Excursion) and critical heat flux in heated microchannels are of great concern in the design and operation of numerous practical systems. In order to prevent Ledinegg flow excursion and eventual burnout of the heated channel, limits are typically imposed on the channel power and coolant mass flux to avoid the possibility of operation within the negatively-sloped region of the coolant channel demand curve. The primary purpose of this investigation was to experimentally determine the effect of design and operational parameters on the onset of flow instability (OFI) and critical heat flux (CHE) in thin, horizontal, uniformly-heated annuli. The work was motivated by the need for such data for the design and safety analysis of the Accelerator Production of Tritium (APT) project under development at Los Alamos National Laboratory. To this end, thirteen different experimental setups were employed to determine the OFI and CHF behavior of annular channels with hydraulic diameters on the order of two millimeters (annular gap widths of approximately 1.0 mm). The OFI data were then compiled and used to create two correlations; one comparing OFI heat flux to saturation heat flux and the other comparing OFI mass flux to saturation mass flux. The CHF data acquired in this investigation were compared with several empirical CHF correlations available in the literature and used to demonstrate that OFI, rather than CHF, is the limiting phenomenon in micro channel heat transfer.","abstract_html":"Two-phase flow instability (Ledinegg Excursion) and critical heat flux in heated microchannels are of great concern in the design and operation of numerous practical systems. In order to prevent Ledinegg flow excursion and eventual burnout of the heated channel, limits are typically imposed on the channel power and coolant mass flux to avoid the possibility of operation within the negatively-sloped region of the coolant channel demand curve. The primary purpose of this investigation was to experimentally determine the effect of design and operational parameters on the onset of flow instability (OFI) and critical heat flux (CHE) in thin, horizontal, uniformly-heated annuli. The work was motivated by the need for such data for the design and safety analysis of the Accelerator Production of Tritium (APT) project under development at Los Alamos National Laboratory. To this end, thirteen different experimental setups were employed to determine the OFI and CHF behavior of annular channels with hydraulic diameters on the order of two millimeters (annular gap widths of approximately 1.0 mm). The OFI data were then compiled and used to create two correlations; one comparing OFI heat flux to saturation heat flux and the other comparing OFI mass flux to saturation mass flux. The CHF data acquired in this investigation were compared with several empirical CHF correlations available in the literature and used to demonstrate that OFI, rather than CHF, is the limiting phenomenon in micro channel heat transfer.","abstract_has_math":false,"creators":["Stoddard, Ryan M."],"institution":"Georgia Institute of Technology","degree_name":"Master of Science in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2000,"date_issued":"2000-04","date_published":"2000-04","updated_at":"2026-11-19T06:26:20Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Distribution Statement A. Approved for public release: Distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/24364","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/24364","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F24364","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["CIVINS (Civilian Institutions)"]},{"key":"dc:creator","label":"Author","values":["Stoddard, Ryan M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-12-13T18:44:10Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-12-13T18:44:10Z"]},{"key":"dc:date.issued","label":"Date","values":["2000-04"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["CIVINS (Civilian Institutions) Theses and Dissertations"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c6eb8929-c883-4d31-84f5-166ce3ae8c52"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["0855bc76-cf0d-4c5f-84ba-3b1c54b01904"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Georgia Institute of Technology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Distribution Statement A. Approved for public release: Distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/24364"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Two-phase flow instability (Ledinegg Excursion) and critical heat flux in heated microchannels are of great concern in the design and operation of numerous practical systems. In order to prevent Ledinegg flow excursion and eventual burnout of the heated channel, limits are typically imposed on the channel power and coolant mass flux to avoid the possibility of operation within the negatively-sloped region of the coolant channel demand curve. The primary purpose of this investigation was to experimentally determine the effect of design and operational parameters on the onset of flow instability (OFI) and critical heat flux (CHE) in thin, horizontal, uniformly-heated annuli. The work was motivated by the need for such data for the design and safety analysis of the Accelerator Production of Tritium (APT) project under development at Los Alamos National Laboratory. To this end, thirteen different experimental setups were employed to determine the OFI and CHF behavior of annular channels with hydraulic diameters on the order of two millimeters (annular gap widths of approximately 1.0 mm). The OFI data were then compiled and used to create two correlations; one comparing OFI heat flux to saturation heat flux and the other comparing OFI mass flux to saturation mass flux. The CHF data acquired in this investigation were compared with several empirical CHF correlations available in the literature and used to demonstrate that OFI, rather than CHF, is the limiting phenomenon in micro channel heat transfer."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["N62271-97-G-0021"]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/onsetofflowinsta1094524364"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["265 p."]},{"key":"dc:title","label":"Title","values":["Onset of flow instability and critical heat flux in horizontal, thin, uniformly- heated annuli"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.other":["CIVINS (Civilian Institutions)"],"dc:creator":["Stoddard, Ryan M."],"dc:date.accessioned":["2012-12-13T18:44:10Z"],"dc:date.available":["2012-12-13T18:44:10Z"],"dc:date.issued":["2000-04"],"dc:description.abstract":["Two-phase flow instability (Ledinegg Excursion) and critical heat flux in heated microchannels are of great concern in the design and operation of numerous practical systems. In order to prevent Ledinegg flow excursion and eventual burnout of the heated channel, limits are typically imposed on the channel power and coolant mass flux to avoid the possibility of operation within the negatively-sloped region of the coolant channel demand curve. The primary purpose of this investigation was to experimentally determine the effect of design and operational parameters on the onset of flow instability (OFI) and critical heat flux (CHE) in thin, horizontal, uniformly-heated annuli. The work was motivated by the need for such data for the design and safety analysis of the Accelerator Production of Tritium (APT) project under development at Los Alamos National Laboratory. To this end, thirteen different experimental setups were employed to determine the OFI and CHF behavior of annular channels with hydraulic diameters on the order of two millimeters (annular gap widths of approximately 1.0 mm). The OFI data were then compiled and used to create two correlations; one comparing OFI heat flux to saturation heat flux and the other comparing OFI mass flux to saturation mass flux. The CHF data acquired in this investigation were compared with several empirical CHF correlations available in the literature and used to demonstrate that OFI, rather than CHF, is the limiting phenomenon in micro channel heat transfer."],"dc:description.sponsorship":["N62271-97-G-0021"],"dc:description.uri":["http://archive.org/details/onsetofflowinsta1094524364"],"dc:format.extent":["265 p."],"dc:identifier.uri":["https://hdl.handle.net/10945/24364"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.ispartofseries":["CIVINS (Civilian Institutions) Theses and Dissertations"],"dc:relation.orgunit":["c6eb8929-c883-4d31-84f5-166ce3ae8c52"],"dc:relation.seriesentity":["0855bc76-cf0d-4c5f-84ba-3b1c54b01904"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Distribution Statement A. Approved for public release: Distribution is unlimited."],"dc:title":["Onset of flow instability and critical heat flux in horizontal, thin, uniformly- heated annuli"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Mechanical Engineering"],"thesis:institution_name":["Georgia Institute of Technology"]},"updated_at":"2026-11-19T06:26:20Z"}