{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/24808"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/24808","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Power level determination from induced gamma activity in nuclear reactor coolants.","abstract":"The operation of a nuclear power plant Involves a variety of instrumentation, most of which is of a conventional character. However, for control purposes, conventional instrumentation for power level determination is not adequate since it does not respond instantaneously either to overall or to local changes in reactor power. The reactor power level is proportional to the neutron flux, and instruments that measure flux can be located at many points throughout the reactor system. Such devices have an essentially instantaneous response and are suitable for indicating power levels and for operating automatic control and safety mechanisms.","abstract_html":"The operation of a nuclear power plant Involves a variety of instrumentation, most of which is of a conventional character. However, for control purposes, conventional instrumentation for power level determination is not adequate since it does not respond instantaneously either to overall or to local changes in reactor power. The reactor power level is proportional to the neutron flux, and instruments that measure flux can be located at many points throughout the reactor system. Such devices have an essentially instantaneous response and are suitable for indicating power levels and for operating automatic control and safety mechanisms.","abstract_has_math":false,"creators":["Wallace, William Dean"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S. in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1956,"date_issued":"1956-06","date_published":"1956-06","updated_at":"2026-11-24T23:53:15Z","subjects":["Nuclear physics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/24808","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/24808","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F24808","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F24808","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Wallace, William Dean"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-12-26T23:08:36Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-12-26T23:08:36Z"]},{"key":"dc:date.issued","label":"Date","values":["1956-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Nuclear physics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/24808"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The operation of a nuclear power plant Involves a variety of instrumentation, most of which is of a conventional character. However, for control purposes, conventional instrumentation for power level determination is not adequate since it does not respond instantaneously either to overall or to local changes in reactor power. The reactor power level is proportional to the neutron flux, and instruments that measure flux can be located at many points throughout the reactor system. Such devices have an essentially instantaneous response and are suitable for indicating power levels and for operating automatic control and safety mechanisms."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/powerleveldeterm1094524808"]},{"key":"dc:title","label":"Title","values":["Power level determination from induced gamma activity in nuclear reactor coolants."]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Wallace, William Dean"],"dc:date.accessioned":["2012-12-26T23:08:36Z"],"dc:date.available":["2012-12-26T23:08:36Z"],"dc:date.issued":["1956-06"],"dc:description.abstract":["The operation of a nuclear power plant Involves a variety of instrumentation, most of which is of a conventional character. However, for control purposes, conventional instrumentation for power level determination is not adequate since it does not respond instantaneously either to overall or to local changes in reactor power. The reactor power level is proportional to the neutron flux, and instruments that measure flux can be located at many points throughout the reactor system. Such devices have an essentially instantaneous response and are suitable for indicating power levels and for operating automatic control and safety mechanisms."],"dc:description.uri":["http://archive.org/details/powerleveldeterm1094524808"],"dc:identifier.uri":["https://hdl.handle.net/10945/24808"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:subject.lcsh":["Nuclear physics"],"dc:title":["Power level determination from induced gamma activity in nuclear reactor coolants."],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-24T23:53:15Z"}