{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/25816"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/25816","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Design consideration for the X-ray Cerenkov experiment","abstract":"The feasibility of measuring Cerenkov radiation in the X-ray region was investigated. It is found that the experimental measurement of X-ray Cerenkov radiation is possible for the carbon K (283.84 eV), aluminum L1 (87.01 eV) and L2,3 (72.78 eV) absorption edges. Measurement in the aluminum K (1559.9 eV) absorption edge region was found to be not possible since the real part of the index of refraction did not exceed unity. The relative power from Cerenkov radiation was calculated for the three possible cases and count rate estimates were given. The experimental apparatus for the measurement of X-ray Cerenkov radiation was redesigned to allow measurement of the carbon K edge and aluminum L1 edge. An experiment was attempted, but not completed due to the failure of a necessary preamplifier for a proportional counter. New design considerations were presented and incorporated changes to avoid the experimental shortcomings of previous measurements","abstract_html":"The feasibility of measuring Cerenkov radiation in the X-ray region was investigated. It is found that the experimental measurement of X-ray Cerenkov radiation is possible for the carbon K (283.84 eV), aluminum L1 (87.01 eV) and L2,3 (72.78 eV) absorption edges. Measurement in the aluminum K (1559.9 eV) absorption edge region was found to be not possible since the real part of the index of refraction did not exceed unity. The relative power from Cerenkov radiation was calculated for the three possible cases and count rate estimates were given. The experimental apparatus for the measurement of X-ray Cerenkov radiation was redesigned to allow measurement of the carbon K edge and aluminum L1 edge. An experiment was attempted, but not completed due to the failure of a necessary preamplifier for a proportional counter. New design considerations were presented and incorporated changes to avoid the experimental shortcomings of previous measurements","abstract_has_math":false,"creators":["Choi, Youn Dae"],"institution":"Naval Postgraduate School","degree_name":"M.S. in Physics","degree_level":"Masters","degree_discipline":"Physics","degree_department":"Physics","school":"Naval Postgraduate School (U.S.)","contributors":[],"advisors":["Neighbours, John R."],"committee_chairs":[],"committee_members":["Maruyama, Xavier K."],"year":1984,"date_issued":"1984-12-01","date_published":"1984-12-01","updated_at":"2026-11-19T21:59:20Z","subjects":["Physics"],"languages":[],"rights":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/25816","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/25816","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F25816","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F25816","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Neighbours, John R."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Maruyama, Xavier K."]},{"key":"dc:contributor.department","label":"Department","values":["Physics"]},{"key":"dc:contributor.school","label":"School","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Choi, Youn Dae"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["December 1984"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-01-23T21:54:11Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-01-23T21:54:11Z"]},{"key":"dc:date.issued","label":"Date","values":["1984-12-01"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Cerenkov Radiation","X-ray","Proportional Counter"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/25816"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The feasibility of measuring Cerenkov radiation in the X-ray region was investigated. It is found that the experimental measurement of X-ray Cerenkov radiation is possible for the carbon K (283.84 eV), aluminum L1 (87.01 eV) and L2,3 (72.78 eV) absorption edges. Measurement in the aluminum K (1559.9 eV) absorption edge region was found to be not possible since the real part of the index of refraction did not exceed unity. The relative power from Cerenkov radiation was calculated for the three possible cases and count rate estimates were given. The experimental apparatus for the measurement of X-ray Cerenkov radiation was redesigned to allow measurement of the carbon K edge and aluminum L1 edge. An experiment was attempted, but not completed due to the failure of a necessary preamplifier for a proportional counter. New design considerations were presented and incorporated changes to avoid the experimental shortcomings of previous measurements"]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/designconsiderat1094525816"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["50 p.;28 cm."]},{"key":"dc:title","label":"Title","values":["Design consideration for the X-ray Cerenkov experiment"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Republic of Korea Army author.","Major, Republic of Korea Army"]}]}],"canonical_facts":{"dc:contributor.advisor":["Neighbours, John R."],"dc:contributor.committeemember":["Maruyama, Xavier K."],"dc:contributor.department":["Physics"],"dc:contributor.school":["Naval Postgraduate School (U.S.)"],"dc:creator":["Choi, Youn Dae"],"dc:date":["December 1984"],"dc:date.accessioned":["2013-01-23T21:54:11Z"],"dc:date.available":["2013-01-23T21:54:11Z"],"dc:date.issued":["1984-12-01"],"dc:description.abstract":["The feasibility of measuring Cerenkov radiation in the X-ray region was investigated. It is found that the experimental measurement of X-ray Cerenkov radiation is possible for the carbon K (283.84 eV), aluminum L1 (87.01 eV) and L2,3 (72.78 eV) absorption edges. Measurement in the aluminum K (1559.9 eV) absorption edge region was found to be not possible since the real part of the index of refraction did not exceed unity. The relative power from Cerenkov radiation was calculated for the three possible cases and count rate estimates were given. The experimental apparatus for the measurement of X-ray Cerenkov radiation was redesigned to allow measurement of the carbon K edge and aluminum L1 edge. An experiment was attempted, but not completed due to the failure of a necessary preamplifier for a proportional counter. New design considerations were presented and incorporated changes to avoid the experimental shortcomings of previous measurements"],"dc:description.uri":["http://archive.org/details/designconsiderat1094525816"],"dc:format.extent":["50 p.;28 cm."],"dc:identifier.uri":["https://hdl.handle.net/10945/25816"],"dc:rights":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Cerenkov Radiation","X-ray","Proportional Counter"],"dc:subject.lcsh":["Physics"],"dc:title":["Design consideration for the X-ray Cerenkov experiment"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Republic of Korea Army author.","Major, Republic of Korea Army"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Physics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T21:59:20Z"}