{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/25856"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/25856","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Dose analysis of the Model 112A Pulserad Pulsed X-Ray Generator by ITS/CYLTRAN.","abstract":"The radiation output from the NPS Pulserad 112A X—ray Generator has been calculated using the ITS code CYLTRAN. The results of this numerical simulation have been compared to the experimental measurements taken previously. These calculations show that the overall photon energy spectrum is independent of the electron source beam parameters such as beam radius and angular distribution. A previously unexplained measured dip in the radiation dose at the beam center line can be explained with an angular divergence of the electron beam from the cathode. The simulation is successful in explaining the pattern of the dose distribution, but the calculation is in general much smaller than the measured values. This inability to reproduce the magnitude of the dose pattern points out the need to measure the radiation dose each time the Pulserad 112A is used. Some suggestions for explaining this discrepancy are included.","abstract_html":"The radiation output from the NPS Pulserad 112A X—ray Generator has been calculated using the ITS code CYLTRAN. The results of this numerical simulation have been compared to the experimental measurements taken previously. These calculations show that the overall photon energy spectrum is independent of the electron source beam parameters such as beam radius and angular distribution. A previously unexplained measured dip in the radiation dose at the beam center line can be explained with an angular divergence of the electron beam from the cathode. The simulation is successful in explaining the pattern of the dose distribution, but the calculation is in general much smaller than the measured values. This inability to reproduce the magnitude of the dose pattern points out the need to measure the radiation dose each time the Pulserad 112A is used. Some suggestions for explaining this discrepancy are included.","abstract_has_math":false,"creators":["Kim, Jong Ryul"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S. in Physics","degree_level":"Masters","degree_discipline":"Physics","degree_department":"Physics","school":null,"contributors":[],"advisors":["Maruyama, Xavier K."],"committee_chairs":[],"committee_members":["Neighbour, J.R."],"year":1989,"date_issued":"1989-12","date_published":"1989-12","updated_at":"2026-11-19T06:26:49Z","subjects":[],"languages":[],"rights":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/25856","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/25856","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F25856","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F25856","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Maruyama, Xavier K."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Neighbour, J.R."]},{"key":"dc:contributor.department","label":"Department","values":["Physics"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Kim, Jong Ryul"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["December 1989"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-01-23T21:54:31Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-01-23T21:54:31Z"]},{"key":"dc:date.issued","label":"Date","values":["1989-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["flash x-ray","ITS/CYLTRAN","Monte Carlo"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/25856"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The radiation output from the NPS Pulserad 112A X—ray Generator has been calculated using the ITS code CYLTRAN. The results of this numerical simulation have been compared to the experimental measurements taken previously. These calculations show that the overall photon energy spectrum is independent of the electron source beam parameters such as beam radius and angular distribution. A previously unexplained measured dip in the radiation dose at the beam center line can be explained with an angular divergence of the electron beam from the cathode. The simulation is successful in explaining the pattern of the dose distribution, but the calculation is in general much smaller than the measured values. This inability to reproduce the magnitude of the dose pattern points out the need to measure the radiation dose each time the Pulserad 112A is used. Some suggestions for explaining this discrepancy are included."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/dosenalysisofmod1094525856"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["74 p."]},{"key":"dc:title","label":"Title","values":["Dose analysis of the Model 112A Pulserad Pulsed X-Ray Generator by ITS/CYLTRAN."]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Major, Republic of Korea Army"]}]}],"canonical_facts":{"dc:contributor.advisor":["Maruyama, Xavier K."],"dc:contributor.committeemember":["Neighbour, J.R."],"dc:contributor.department":["Physics"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Kim, Jong Ryul"],"dc:date":["December 1989"],"dc:date.accessioned":["2013-01-23T21:54:31Z"],"dc:date.available":["2013-01-23T21:54:31Z"],"dc:date.issued":["1989-12"],"dc:description.abstract":["The radiation output from the NPS Pulserad 112A X—ray Generator has been calculated using the ITS code CYLTRAN. The results of this numerical simulation have been compared to the experimental measurements taken previously. These calculations show that the overall photon energy spectrum is independent of the electron source beam parameters such as beam radius and angular distribution. A previously unexplained measured dip in the radiation dose at the beam center line can be explained with an angular divergence of the electron beam from the cathode. The simulation is successful in explaining the pattern of the dose distribution, but the calculation is in general much smaller than the measured values. This inability to reproduce the magnitude of the dose pattern points out the need to measure the radiation dose each time the Pulserad 112A is used. Some suggestions for explaining this discrepancy are included."],"dc:description.uri":["http://archive.org/details/dosenalysisofmod1094525856"],"dc:format.extent":["74 p."],"dc:identifier.uri":["https://hdl.handle.net/10945/25856"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["flash x-ray","ITS/CYLTRAN","Monte Carlo"],"dc:title":["Dose analysis of the Model 112A Pulserad Pulsed X-Ray Generator by ITS/CYLTRAN."],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Major, Republic of Korea Army"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Physics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:26:49Z"}