{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/26462"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/26462","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Determining the effect of endwall boundary layer suction in a large scale subsonic compressor cascade","abstract":"An arrangement of suction slots was installed in the Naval Postgraduate School's subsonic cascade wind tunnel. The aim was to improve flow two-dimensionality to enable flow separation of the installed controlled- diffusion blades at high incidence. The slots were located 17.25 inches upstream of the test section. Pressure and laser Doppler velocimetry measurements were made, for a Reynolds number of 711000 and an inlet flow angle of 44.4 deg, upstream and downstream of the test section to determine the effects of varying suction. The set of baseline inlet flow field measurements was to be used for comparison purposes in future tunnel modifications. The results showed that the tunnel endwall boundary layers were asymmetric for the baseline configuration. Uniform suction was not achieved in both the pitchwise and spanwise directions. However, the axial velocity ratio was reduced by 1.9% and the blade loading increased slightly with increased suction","abstract_html":"An arrangement of suction slots was installed in the Naval Postgraduate School&#x27;s subsonic cascade wind tunnel. The aim was to improve flow two-dimensionality to enable flow separation of the installed controlled- diffusion blades at high incidence. The slots were located 17.25 inches upstream of the test section. Pressure and laser Doppler velocimetry measurements were made, for a Reynolds number of 711000 and an inlet flow angle of 44.4 deg, upstream and downstream of the test section to determine the effects of varying suction. The set of baseline inlet flow field measurements was to be used for comparison purposes in future tunnel modifications. The results showed that the tunnel endwall boundary layers were asymmetric for the baseline configuration. Uniform suction was not achieved in both the pitchwise and spanwise directions. However, the axial velocity ratio was reduced by 1.9% and the blade loading increased slightly with increased suction","abstract_has_math":false,"creators":["Webber, Matthew Allen"],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Aeronautical Engineering","degree_level":"Masters","degree_discipline":"Aeronautical Engineering","degree_department":"Aeronautical Engineering","school":"Naval Postgraduate School","contributors":[],"advisors":["Hobson, Garth V."],"committee_chairs":[],"committee_members":["Shreeve, Raymond P."],"year":1993,"date_issued":"1993-03","date_published":"1993-03","updated_at":"2026-11-21T22:48:16Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/26462","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/26462","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F26462","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F26462","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Hobson, Garth V."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Shreeve, Raymond P."]},{"key":"dc:contributor.department","label":"Department","values":["Aeronautical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School"]},{"key":"dc:contributor.school","label":"School","values":["Naval Postgraduate School"]},{"key":"dc:creator","label":"Author","values":["Webber, Matthew Allen"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-01-23T21:59:41Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-01-23T21:59:41Z"]},{"key":"dc:date.issued","label":"Date","values":["1993-03"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Aeronautical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Aeronautical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/26462"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An arrangement of suction slots was installed in the Naval Postgraduate School's subsonic cascade wind tunnel. The aim was to improve flow two-dimensionality to enable flow separation of the installed controlled- diffusion blades at high incidence. The slots were located 17.25 inches upstream of the test section. Pressure and laser Doppler velocimetry measurements were made, for a Reynolds number of 711000 and an inlet flow angle of 44.4 deg, upstream and downstream of the test section to determine the effects of varying suction. The set of baseline inlet flow field measurements was to be used for comparison purposes in future tunnel modifications. The results showed that the tunnel endwall boundary layers were asymmetric for the baseline configuration. Uniform suction was not achieved in both the pitchwise and spanwise directions. However, the axial velocity ratio was reduced by 1.9% and the blade loading increased slightly with increased suction"]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/determiningeffec1094526462"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["131 p."]},{"key":"dc:title","label":"Title","values":["Determining the effect of endwall boundary layer suction in a large scale subsonic compressor cascade"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Hobson, Garth V."],"dc:contributor.committeemember":["Shreeve, Raymond P."],"dc:contributor.department":["Aeronautical Engineering"],"dc:contributor.other":["Naval Postgraduate School"],"dc:contributor.school":["Naval Postgraduate School"],"dc:creator":["Webber, Matthew Allen"],"dc:date.accessioned":["2013-01-23T21:59:41Z"],"dc:date.available":["2013-01-23T21:59:41Z"],"dc:date.issued":["1993-03"],"dc:description.abstract":["An arrangement of suction slots was installed in the Naval Postgraduate School's subsonic cascade wind tunnel. The aim was to improve flow two-dimensionality to enable flow separation of the installed controlled- diffusion blades at high incidence. The slots were located 17.25 inches upstream of the test section. Pressure and laser Doppler velocimetry measurements were made, for a Reynolds number of 711000 and an inlet flow angle of 44.4 deg, upstream and downstream of the test section to determine the effects of varying suction. The set of baseline inlet flow field measurements was to be used for comparison purposes in future tunnel modifications. The results showed that the tunnel endwall boundary layers were asymmetric for the baseline configuration. Uniform suction was not achieved in both the pitchwise and spanwise directions. However, the axial velocity ratio was reduced by 1.9% and the blade loading increased slightly with increased suction"],"dc:description.uri":["http://archive.org/details/determiningeffec1094526462"],"dc:format.extent":["131 p."],"dc:identifier.uri":["https://hdl.handle.net/10945/26462"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:title":["Determining the effect of endwall boundary layer suction in a large scale subsonic compressor cascade"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Aeronautical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Aeronautical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T22:48:16Z"}