{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/26565"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/26565","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Full pose and partial pose calibration of a six degree of freedom robot manipulator arm","abstract":"A six degree of freedom robot manipulator arm, a PUMA 560, is calibrated using full pose and partial pose methods in order to improve the accuracy of the manipulator arm. The theory applied to modeling of mechanisms is introduced. A thirty parameter kinematic model is developed for use in the full pose calibration methods and a twenty-six parametric kinematic model is developed for the partial pose calibration. A simulation study is performed to determine the applicability and feasibility of each model. Experimental pose measurements are performed using each method to obtain data with which to perform an actual calibration of the manipulator and compare with the predicted results. The effects of noise in each measurement system employed and in the manipulator's joint position encoders are discussed. The measurement systems employed are examined in detail and a comparison between the two is performed. The measured kinematic parameters of each model are presented as results.","abstract_html":"A six degree of freedom robot manipulator arm, a PUMA 560, is calibrated using full pose and partial pose methods in order to improve the accuracy of the manipulator arm. The theory applied to modeling of mechanisms is introduced. A thirty parameter kinematic model is developed for use in the full pose calibration methods and a twenty-six parametric kinematic model is developed for the partial pose calibration. A simulation study is performed to determine the applicability and feasibility of each model. Experimental pose measurements are performed using each method to obtain data with which to perform an actual calibration of the manipulator and compare with the predicted results. The effects of noise in each measurement system employed and in the manipulator&#x27;s joint position encoders are discussed. The measurement systems employed are examined in detail and a comparison between the two is performed. The measured kinematic parameters of each model are presented as results.","abstract_has_math":false,"creators":["Potter, Scott Alton"],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Driels, Morris R."],"committee_chairs":[],"committee_members":[],"year":1991,"date_issued":"1991-09","date_published":"1991-09","updated_at":"2026-11-20T22:09:13Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/26565","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/26565","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F26565","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Driels, Morris R."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Potter, Scott Alton"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["September 1991"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-01-23T22:00:32Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-01-23T22:00:32Z"]},{"key":"dc:date.issued","label":"Date","values":["1991-09"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Robot manipulator calibration"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/26565"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A six degree of freedom robot manipulator arm, a PUMA 560, is calibrated using full pose and partial pose methods in order to improve the accuracy of the manipulator arm. The theory applied to modeling of mechanisms is introduced. A thirty parameter kinematic model is developed for use in the full pose calibration methods and a twenty-six parametric kinematic model is developed for the partial pose calibration. A simulation study is performed to determine the applicability and feasibility of each model. Experimental pose measurements are performed using each method to obtain data with which to perform an actual calibration of the manipulator and compare with the predicted results. The effects of noise in each measurement system employed and in the manipulator's joint position encoders are discussed. The measurement systems employed are examined in detail and a comparison between the two is performed. The measured kinematic parameters of each model are presented as results."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/fullposendpartia1094526565"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["120 p."]},{"key":"dc:title","label":"Title","values":["Full pose and partial pose calibration of a six degree of freedom robot manipulator arm"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Driels, Morris R."],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Potter, Scott Alton"],"dc:date":["September 1991"],"dc:date.accessioned":["2013-01-23T22:00:32Z"],"dc:date.available":["2013-01-23T22:00:32Z"],"dc:date.issued":["1991-09"],"dc:description.abstract":["A six degree of freedom robot manipulator arm, a PUMA 560, is calibrated using full pose and partial pose methods in order to improve the accuracy of the manipulator arm. The theory applied to modeling of mechanisms is introduced. A thirty parameter kinematic model is developed for use in the full pose calibration methods and a twenty-six parametric kinematic model is developed for the partial pose calibration. A simulation study is performed to determine the applicability and feasibility of each model. Experimental pose measurements are performed using each method to obtain data with which to perform an actual calibration of the manipulator and compare with the predicted results. The effects of noise in each measurement system employed and in the manipulator's joint position encoders are discussed. The measurement systems employed are examined in detail and a comparison between the two is performed. The measured kinematic parameters of each model are presented as results."],"dc:description.uri":["http://archive.org/details/fullposendpartia1094526565"],"dc:format.extent":["120 p."],"dc:identifier.uri":["https://hdl.handle.net/10945/26565"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Robot manipulator calibration"],"dc:title":["Full pose and partial pose calibration of a six degree of freedom robot manipulator arm"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-20T22:09:13Z"}