{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/26595"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/26595","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Interaction effects of a lower heated tube on pool boiling of R-124 from an upper horizontal tube","abstract":"An investigation of the interaction effects of a lower heated tube on pool boiling of pure R-124 from an upper horizontal tube was conducted at a saturation temperature of 2.2 deg C. The test tubes used were: (1) smooth tubes and (2) deformed surface (TURBO-B) enhanced tubes. The effects of tube spacing/configuration and lower tube heat flux on the heat transfer performance of the upper tube were investigated. For both tube arrays, the enhancing effect of bubbles from a lower tube was dramatic. This enhancement increased as lower tube heat flux increased. However, when upper tube heat fluxes were greater than 20 kW/sq. meters all enhancement disappeared. For a smooth tube array in natural convection, the effect of a lower heated tube on the heat transfer from an upper tube was small. In nucleate boiling, a P/D of 1.8 gave the best upper tube heat transfer performance and a vigorously nucleating lower tube eliminated upper tube hysteresis. With the lower tube unheated and an upper tube heat flux of greater than 3 kW/m2, the performance using R-124 was generally better than for R-114. With a nucleating lower tube (at lO kW/sq. meters), again the performance of R-124 was better, but only for upper tube heat fluxes of greater than 40 kW/sq. meters. For a TURBO-B tube array, a 30 degree offset of the upper tube reduced the upper tube heat transfer performance (compared to the in-line configurations). This may indicate bubbles depart TURBO-B tubes differently than smooth tubes","abstract_html":"An investigation of the interaction effects of a lower heated tube on pool boiling of pure R-124 from an upper horizontal tube was conducted at a saturation temperature of 2.2 deg C. The test tubes used were: (1) smooth tubes and (2) deformed surface (TURBO-B) enhanced tubes. The effects of tube spacing/configuration and lower tube heat flux on the heat transfer performance of the upper tube were investigated. For both tube arrays, the enhancing effect of bubbles from a lower tube was dramatic. This enhancement increased as lower tube heat flux increased. However, when upper tube heat fluxes were greater than 20 kW/sq. meters all enhancement disappeared. For a smooth tube array in natural convection, the effect of a lower heated tube on the heat transfer from an upper tube was small. In nucleate boiling, a P/D of 1.8 gave the best upper tube heat transfer performance and a vigorously nucleating lower tube eliminated upper tube hysteresis. With the lower tube unheated and an upper tube heat flux of greater than 3 kW/m2, the performance using R-124 was generally better than for R-114. With a nucleating lower tube (at lO kW/sq. meters), again the performance of R-124 was better, but only for upper tube heat fluxes of greater than 40 kW/sq. meters. For a TURBO-B tube array, a 30 degree offset of the upper tube reduced the upper tube heat transfer performance (compared to the in-line configurations). This may indicate bubbles depart TURBO-B tubes differently than smooth tubes","abstract_has_math":false,"creators":["Yusician, Joseph E."],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":"Naval Postgraduate School","contributors":[],"advisors":["Marto, Paul J.","Memory, Stephen B."],"committee_chairs":[],"committee_members":[],"year":1993,"date_issued":"1993-12","date_published":"1993-12","updated_at":"2026-11-21T23:34:39Z","subjects":[],"languages":[],"rights":["Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/26595","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/26595","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F26595","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F26595","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Marto, Paul J.","Memory, Stephen B."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School"]},{"key":"dc:contributor.school","label":"School","values":["Naval Postgraduate School"]},{"key":"dc:creator","label":"Author","values":["Yusician, Joseph E."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-01-23T22:01:54Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-01-23T22:01:54Z"]},{"key":"dc:date.issued","label":"Date","values":["1993-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/26595"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An investigation of the interaction effects of a lower heated tube on pool boiling of pure R-124 from an upper horizontal tube was conducted at a saturation temperature of 2.2 deg C. The test tubes used were: (1) smooth tubes and (2) deformed surface (TURBO-B) enhanced tubes. The effects of tube spacing/configuration and lower tube heat flux on the heat transfer performance of the upper tube were investigated. For both tube arrays, the enhancing effect of bubbles from a lower tube was dramatic. This enhancement increased as lower tube heat flux increased. However, when upper tube heat fluxes were greater than 20 kW/sq. meters all enhancement disappeared. For a smooth tube array in natural convection, the effect of a lower heated tube on the heat transfer from an upper tube was small. In nucleate boiling, a P/D of 1.8 gave the best upper tube heat transfer performance and a vigorously nucleating lower tube eliminated upper tube hysteresis. With the lower tube unheated and an upper tube heat flux of greater than 3 kW/m2, the performance using R-124 was generally better than for R-114. With a nucleating lower tube (at lO kW/sq. meters), again the performance of R-124 was better, but only for upper tube heat fluxes of greater than 40 kW/sq. meters. For a TURBO-B tube array, a 30 degree offset of the upper tube reduced the upper tube heat transfer performance (compared to the in-line configurations). This may indicate bubbles depart TURBO-B tubes differently than smooth tubes"]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/interactioneffec1094526595"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["169 p."]},{"key":"dc:title","label":"Title","values":["Interaction effects of a lower heated tube on pool boiling of R-124 from an upper horizontal tube"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Marto, Paul J.","Memory, Stephen B."],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["Naval Postgraduate School"],"dc:contributor.school":["Naval Postgraduate School"],"dc:creator":["Yusician, Joseph E."],"dc:date.accessioned":["2013-01-23T22:01:54Z"],"dc:date.available":["2013-01-23T22:01:54Z"],"dc:date.issued":["1993-12"],"dc:description.abstract":["An investigation of the interaction effects of a lower heated tube on pool boiling of pure R-124 from an upper horizontal tube was conducted at a saturation temperature of 2.2 deg C. The test tubes used were: (1) smooth tubes and (2) deformed surface (TURBO-B) enhanced tubes. The effects of tube spacing/configuration and lower tube heat flux on the heat transfer performance of the upper tube were investigated. For both tube arrays, the enhancing effect of bubbles from a lower tube was dramatic. This enhancement increased as lower tube heat flux increased. However, when upper tube heat fluxes were greater than 20 kW/sq. meters all enhancement disappeared. For a smooth tube array in natural convection, the effect of a lower heated tube on the heat transfer from an upper tube was small. In nucleate boiling, a P/D of 1.8 gave the best upper tube heat transfer performance and a vigorously nucleating lower tube eliminated upper tube hysteresis. With the lower tube unheated and an upper tube heat flux of greater than 3 kW/m2, the performance using R-124 was generally better than for R-114. With a nucleating lower tube (at lO kW/sq. meters), again the performance of R-124 was better, but only for upper tube heat fluxes of greater than 40 kW/sq. meters. For a TURBO-B tube array, a 30 degree offset of the upper tube reduced the upper tube heat transfer performance (compared to the in-line configurations). This may indicate bubbles depart TURBO-B tubes differently than smooth tubes"],"dc:description.uri":["http://archive.org/details/interactioneffec1094526595"],"dc:format.extent":["169 p."],"dc:identifier.uri":["https://hdl.handle.net/10945/26595"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["Approved for public release; distribution is unlimited."],"dc:title":["Interaction effects of a lower heated tube on pool boiling of R-124 from an upper horizontal tube"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T23:34:39Z"}