{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/26642"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/26642","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Modification and experimental validation of a combined optical and collection probe for solid propellant exhaust analysis","abstract":"A combined optical and collection particle sizing probe was further developed and utilized for in situ measurements in the exhaust plumes of solid propellant rocket motors. Probe shock-swallowing capabilities were verified using Schlieren observations under restricted motor operating conditions. Particle size number distributions obtained optically using a Malvern Mastersizer and from an automated data retrieval system for scanning electron microscope photographs of collected particles were in good agreement when referenced to common measurement limits. Most of the particles were smaller than 0.5 u but a significant number were present with diameters 19 10 u. A very few particles large than 15 u were also present, some as single particles and some as agglomerates. SEM results showed that many particles were smaller than 0.2 u outside the range of the Malvern instrument. Suggestions are made for further improvements and validation procedures for the probe.","abstract_html":"A combined optical and collection particle sizing probe was further developed and utilized for in situ measurements in the exhaust plumes of solid propellant rocket motors. Probe shock-swallowing capabilities were verified using Schlieren observations under restricted motor operating conditions. Particle size number distributions obtained optically using a Malvern Mastersizer and from an automated data retrieval system for scanning electron microscope photographs of collected particles were in good agreement when referenced to common measurement limits. Most of the particles were smaller than 0.5 u but a significant number were present with diameters 19 10 u. A very few particles large than 15 u were also present, some as single particles and some as agglomerates. SEM results showed that many particles were smaller than 0.2 u outside the range of the Malvern instrument. Suggestions are made for further improvements and validation procedures for the probe.","abstract_has_math":false,"creators":["Kellman, Lyle J."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S. in Astronautical Engineering","degree_level":"Masters","degree_discipline":"Astronautical Engineering","degree_department":"Department of Aeronautics and Astronautics","school":null,"contributors":[],"advisors":["Netzer, David W.","David, Laredo"],"committee_chairs":[],"committee_members":["Agrawal, Brij N."],"year":1991,"date_issued":"1991-03","date_published":"1991-03","updated_at":"2026-11-26T00:16:55Z","subjects":[],"languages":[],"rights":["Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/26642","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/26642","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F26642","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F26642","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Netzer, David W.","David, Laredo"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Agrawal, Brij N."]},{"key":"dc:contributor.department","label":"Department","values":["Department of Aeronautics and Astronautics"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School"]},{"key":"dc:creator","label":"Author","values":["Kellman, Lyle J."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["March 1991"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-01-23T22:03:32Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-01-23T22:03:32Z"]},{"key":"dc:date.issued","label":"Date","values":["1991-03"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Astronautical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Astronautical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Solid propellant rockets","Particle sizing probe"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/26642"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A combined optical and collection particle sizing probe was further developed and utilized for in situ measurements in the exhaust plumes of solid propellant rocket motors. Probe shock-swallowing capabilities were verified using Schlieren observations under restricted motor operating conditions. Particle size number distributions obtained optically using a Malvern Mastersizer and from an automated data retrieval system for scanning electron microscope photographs of collected particles were in good agreement when referenced to common measurement limits. Most of the particles were smaller than 0.5 u but a significant number were present with diameters 19 10 u. A very few particles large than 15 u were also present, some as single particles and some as agglomerates. SEM results showed that many particles were smaller than 0.2 u outside the range of the Malvern instrument. Suggestions are made for further improvements and validation procedures for the probe."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/modificationndex1094526642"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["80 p."]},{"key":"dc:title","label":"Title","values":["Modification and experimental validation of a combined optical and collection probe for solid propellant exhaust analysis"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Captain, United States Army"]}]}],"canonical_facts":{"dc:contributor.advisor":["Netzer, David W.","David, Laredo"],"dc:contributor.committeemember":["Agrawal, Brij N."],"dc:contributor.department":["Department of Aeronautics and Astronautics"],"dc:contributor.other":["Naval Postgraduate School"],"dc:creator":["Kellman, Lyle J."],"dc:date":["March 1991"],"dc:date.accessioned":["2013-01-23T22:03:32Z"],"dc:date.available":["2013-01-23T22:03:32Z"],"dc:date.issued":["1991-03"],"dc:description.abstract":["A combined optical and collection particle sizing probe was further developed and utilized for in situ measurements in the exhaust plumes of solid propellant rocket motors. Probe shock-swallowing capabilities were verified using Schlieren observations under restricted motor operating conditions. Particle size number distributions obtained optically using a Malvern Mastersizer and from an automated data retrieval system for scanning electron microscope photographs of collected particles were in good agreement when referenced to common measurement limits. Most of the particles were smaller than 0.5 u but a significant number were present with diameters 19 10 u. A very few particles large than 15 u were also present, some as single particles and some as agglomerates. SEM results showed that many particles were smaller than 0.2 u outside the range of the Malvern instrument. Suggestions are made for further improvements and validation procedures for the probe."],"dc:description.uri":["http://archive.org/details/modificationndex1094526642"],"dc:format.extent":["80 p."],"dc:identifier.uri":["https://hdl.handle.net/10945/26642"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Solid propellant rockets","Particle sizing probe"],"dc:title":["Modification and experimental validation of a combined optical and collection probe for solid propellant exhaust analysis"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Captain, United States Army"],"thesis:degree_discipline":["Astronautical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Astronautical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-26T00:16:55Z"}