{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/26928"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/26928","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Comparison of calculations and measurements of the off-axis radiation dose (Si) in liquid nitrogen as a function of radiation length","abstract":"In this thesis results are presented from a study of the off-axis X and Gamma radiation field caused by a highly relativistic electron beam in liquid Nitrogen at various path lengths out to 2 radiation lengths. The off-axis dose in Silicon was calculated using electron/photon transport code CYLTRAN and measured using thermal luminescent dosimeters (TLD's). Calculations were performed on a CDC-7600 computer ar Los Alamos National Laboratory and measurements were made using the Naval Postgraduate School 100 Mev Linac. Comparison of the results is made and CYLTRAN is found to be in agreement with experimentally measured values. The CYLTRAN results are extended to the off-axis dose caused by a 100 Mev electron beam in air at Standard Temperature and Pressure (STP)","abstract_html":"In this thesis results are presented from a study of the off-axis X and Gamma radiation field caused by a highly relativistic electron beam in liquid Nitrogen at various path lengths out to 2 radiation lengths. The off-axis dose in Silicon was calculated using electron/photon transport code CYLTRAN and measured using thermal luminescent dosimeters (TLD&#x27;s). Calculations were performed on a CDC-7600 computer ar Los Alamos National Laboratory and measurements were made using the Naval Postgraduate School 100 Mev Linac. Comparison of the results is made and CYLTRAN is found to be in agreement with experimentally measured values. The CYLTRAN results are extended to the off-axis dose caused by a 100 Mev electron beam in air at Standard Temperature and Pressure (STP)","abstract_has_math":false,"creators":["Cromar, Patrick F."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S. in Physics","degree_level":"Masters","degree_discipline":"Physics","degree_department":"Department of Physics","school":null,"contributors":[],"advisors":["Buskirk, Fred R."],"committee_chairs":[],"committee_members":["Neighbours, J. R."],"year":1984,"date_issued":"1984-12-01","date_published":"1984-12-01","updated_at":"2026-11-24T23:54:39Z","subjects":["Physics"],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/26928","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/26928","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F26928","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F26928","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Buskirk, Fred R."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Neighbours, J. R."]},{"key":"dc:contributor.department","label":"Department","values":["Department of Physics"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Cromar, Patrick F."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["December 1984"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-01-23T22:08:04Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-01-23T22:08:04Z"]},{"key":"dc:date.issued","label":"Date","values":["1984-12-01"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Air Dose","Off-axis dose","Off- axis radiation","Bremsstrahlung"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/26928"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In this thesis results are presented from a study of the off-axis X and Gamma radiation field caused by a highly relativistic electron beam in liquid Nitrogen at various path lengths out to 2 radiation lengths. The off-axis dose in Silicon was calculated using electron/photon transport code CYLTRAN and measured using thermal luminescent dosimeters (TLD's). Calculations were performed on a CDC-7600 computer ar Los Alamos National Laboratory and measurements were made using the Naval Postgraduate School 100 Mev Linac. Comparison of the results is made and CYLTRAN is found to be in agreement with experimentally measured values. The CYLTRAN results are extended to the off-axis dose caused by a 100 Mev electron beam in air at Standard Temperature and Pressure (STP)"]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/comparisonofcalc1094526928"]},{"key":"dc:title","label":"Title","values":["Comparison of calculations and measurements of the off-axis radiation dose (Si) in liquid nitrogen as a function of radiation length"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Buskirk, Fred R."],"dc:contributor.committeemember":["Neighbours, J. R."],"dc:contributor.department":["Department of Physics"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Cromar, Patrick F."],"dc:date":["December 1984"],"dc:date.accessioned":["2013-01-23T22:08:04Z"],"dc:date.available":["2013-01-23T22:08:04Z"],"dc:date.issued":["1984-12-01"],"dc:description.abstract":["In this thesis results are presented from a study of the off-axis X and Gamma radiation field caused by a highly relativistic electron beam in liquid Nitrogen at various path lengths out to 2 radiation lengths. The off-axis dose in Silicon was calculated using electron/photon transport code CYLTRAN and measured using thermal luminescent dosimeters (TLD's). Calculations were performed on a CDC-7600 computer ar Los Alamos National Laboratory and measurements were made using the Naval Postgraduate School 100 Mev Linac. Comparison of the results is made and CYLTRAN is found to be in agreement with experimentally measured values. The CYLTRAN results are extended to the off-axis dose caused by a 100 Mev electron beam in air at Standard Temperature and Pressure (STP)"],"dc:description.uri":["http://archive.org/details/comparisonofcalc1094526928"],"dc:identifier.uri":["https://hdl.handle.net/10945/26928"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Air Dose","Off-axis dose","Off- axis radiation","Bremsstrahlung"],"dc:subject.lcsh":["Physics"],"dc:title":["Comparison of calculations and measurements of the off-axis radiation dose (Si) in liquid nitrogen as a function of radiation length"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Physics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-24T23:54:39Z"}