{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/26995"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/26995","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Differential Loran-C using three secondary stations.","abstract":"Loran-C time difference (TD) readings were taken consecutively at several survey stations near Monterey, CA, over a period of three days. One station, Range-7, was designated the 'known' point of a differential Loran-C system. Readings from the known point were used to correct readings from a second survey station, Luces Point. A method of improving the precision of Loran-C TD readings based on the redundancy and relative accuracy of three LOP's was developed and applied to the data. Since only one receiver was available, a linear regression of TD vs time was calculated and used in the differential correction. Based on 496 sets of data taken at 5-second intervals at Range-7 in two groups, before and after about 250 readings at Luces Point, the absolute accuracy of Luces Point data was improved from about 385 m to about 48 m compared to the known position of the point. Precision was improved from about 14.9 m to about 12.6 m circular error (CEP) using the three-station correction. Further improvement would probably have resulted if two receivers were available for real time corrections. Keywords: LORAN; Differential corrections; Corrections using three secondary stations; Circular error probable; Error ellipse; Time difference; Geographic position; LOP(Line Of Position); Absolute accuracy. Theses","abstract_html":"Loran-C time difference (TD) readings were taken consecutively at several survey stations near Monterey, CA, over a period of three days. One station, Range-7, was designated the &#x27;known&#x27; point of a differential Loran-C system. Readings from the known point were used to correct readings from a second survey station, Luces Point. A method of improving the precision of Loran-C TD readings based on the redundancy and relative accuracy of three LOP&#x27;s was developed and applied to the data. Since only one receiver was available, a linear regression of TD vs time was calculated and used in the differential correction. Based on 496 sets of data taken at 5-second intervals at Range-7 in two groups, before and after about 250 readings at Luces Point, the absolute accuracy of Luces Point data was improved from about 385 m to about 48 m compared to the known position of the point. Precision was improved from about 14.9 m to about 12.6 m circular error (CEP) using the three-station correction. Further improvement would probably have resulted if two receivers were available for real time corrections. Keywords: LORAN; Differential corrections; Corrections using three secondary stations; Circular error probable; Error ellipse; Time difference; Geographic position; LOP(Line Of Position); Absolute accuracy. Theses","abstract_has_math":false,"creators":["Purdy, David F."],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Hydrographic Sciences","degree_level":"Masters","degree_discipline":"Hydrographic Science","degree_department":"Hydrographic Science","school":"NA","contributors":[],"advisors":["Tucker, Stevens P."],"committee_chairs":[],"committee_members":[],"year":1989,"date_issued":"1989","date_published":"1989","updated_at":"2026-11-21T22:49:18Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["ocm23377617"],"render_values":[{"text":"ocm23377617","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/26995","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/26995","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F26995","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F26995","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Tucker, Stevens P."]},{"key":"dc:contributor.department","label":"Department","values":["Hydrographic Science"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["NA"]},{"key":"dc:contributor.school","label":"School","values":["NA"]},{"key":"dc:creator","label":"Author","values":["Purdy, David F."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-01-23T22:08:36Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-01-23T22:08:36Z"]},{"key":"dc:date.issued","label":"Date","values":["1989"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Hydrographic Science"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Hydrographic Sciences"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["ocm23377617"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/26995"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Loran-C time difference (TD) readings were taken consecutively at several survey stations near Monterey, CA, over a period of three days. One station, Range-7, was designated the 'known' point of a differential Loran-C system. Readings from the known point were used to correct readings from a second survey station, Luces Point. A method of improving the precision of Loran-C TD readings based on the redundancy and relative accuracy of three LOP's was developed and applied to the data. Since only one receiver was available, a linear regression of TD vs time was calculated and used in the differential correction. Based on 496 sets of data taken at 5-second intervals at Range-7 in two groups, before and after about 250 readings at Luces Point, the absolute accuracy of Luces Point data was improved from about 385 m to about 48 m compared to the known position of the point. Precision was improved from about 14.9 m to about 12.6 m circular error (CEP) using the three-station correction. Further improvement would probably have resulted if two receivers were available for real time corrections. Keywords: LORAN; Differential corrections; Corrections using three secondary stations; Circular error probable; Error ellipse; Time difference; Geographic position; LOP(Line Of Position); Absolute accuracy. Theses"]},{"key":"dc:description.award","label":"Dc Description Award","values":["NA"]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["NA"]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/differentiallora1094526995"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["88 p."]},{"key":"dc:title","label":"Title","values":["Differential Loran-C using three secondary stations."]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Tucker, Stevens P."],"dc:contributor.department":["Hydrographic Science"],"dc:contributor.other":["NA"],"dc:contributor.school":["NA"],"dc:creator":["Purdy, David F."],"dc:date.accessioned":["2013-01-23T22:08:36Z"],"dc:date.available":["2013-01-23T22:08:36Z"],"dc:date.issued":["1989"],"dc:description.abstract":["Loran-C time difference (TD) readings were taken consecutively at several survey stations near Monterey, CA, over a period of three days. One station, Range-7, was designated the 'known' point of a differential Loran-C system. Readings from the known point were used to correct readings from a second survey station, Luces Point. A method of improving the precision of Loran-C TD readings based on the redundancy and relative accuracy of three LOP's was developed and applied to the data. Since only one receiver was available, a linear regression of TD vs time was calculated and used in the differential correction. Based on 496 sets of data taken at 5-second intervals at Range-7 in two groups, before and after about 250 readings at Luces Point, the absolute accuracy of Luces Point data was improved from about 385 m to about 48 m compared to the known position of the point. Precision was improved from about 14.9 m to about 12.6 m circular error (CEP) using the three-station correction. Further improvement would probably have resulted if two receivers were available for real time corrections. Keywords: LORAN; Differential corrections; Corrections using three secondary stations; Circular error probable; Error ellipse; Time difference; Geographic position; LOP(Line Of Position); Absolute accuracy. Theses"],"dc:description.award":["NA"],"dc:description.sponsorship":["NA"],"dc:description.uri":["http://archive.org/details/differentiallora1094526995"],"dc:format.extent":["88 p."],"dc:identifier.oclc":["ocm23377617"],"dc:identifier.uri":["https://hdl.handle.net/10945/26995"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:title":["Differential Loran-C using three secondary stations."],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_discipline":["Hydrographic Science"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Hydrographic Sciences"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T22:49:18Z"}