{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/27076"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/27076","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Heat transfer, adiabatic effectiveness and injectant distribution downstream of single and double rows of film-cooling holes with compound angles.","abstract":"Experimental results are presented which describe the development and structure of flow downstream of one row and downstream of two staggered rows of film-cooling holes with compound angle orientations. Results presented include distributions of iso-energetic Stanton number ratios, and adiabatic film-cooling effectiveness deduced from Stanton numbers using superposition. Also presented are plots showing the streamwise development of injectant distributions and streamwise development of mean velocity distributions. Spanwise averaged values of the adiabatic film-cooling effectiveness are highest for blowing ratio m=0.5 and decrease as blowing ratio increases for x/d less than 20. At farther downstream positions, spanwise averaged effectiveness values increase with blowing ratio, except for data obtained downstream of two rows of holes with a blowing ratio of 3.0 and data obtained downstream of two rows of holes with a blowing ratio of 3.0 and data obtained downstream of one row of holes with a blowing ratio of 4.0, where severe lift-off of injectant occurs. Spanwise averaged iso-energetic Stanton number ratios range between 1.0 and 1.4 and show little variation as x/d increases for each value of blowing ratio, however for each x/d, values increase with increasing blowing ratio.","abstract_html":"Experimental results are presented which describe the development and structure of flow downstream of one row and downstream of two staggered rows of film-cooling holes with compound angle orientations. Results presented include distributions of iso-energetic Stanton number ratios, and adiabatic film-cooling effectiveness deduced from Stanton numbers using superposition. Also presented are plots showing the streamwise development of injectant distributions and streamwise development of mean velocity distributions. Spanwise averaged values of the adiabatic film-cooling effectiveness are highest for blowing ratio m=0.5 and decrease as blowing ratio increases for x/d less than 20. At farther downstream positions, spanwise averaged effectiveness values increase with blowing ratio, except for data obtained downstream of two rows of holes with a blowing ratio of 3.0 and data obtained downstream of two rows of holes with a blowing ratio of 3.0 and data obtained downstream of one row of holes with a blowing ratio of 4.0, where severe lift-off of injectant occurs. Spanwise averaged iso-energetic Stanton number ratios range between 1.0 and 1.4 and show little variation as x/d increases for each value of blowing ratio, however for each x/d, values increase with increasing blowing ratio.","abstract_has_math":false,"creators":["Wigle, James Michael"],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":"Naval Postgraduate School","contributors":[],"advisors":["Ligrani, Phillip M."],"committee_chairs":[],"committee_members":[],"year":1991,"date_issued":"1991-12","date_published":"1991-12","updated_at":"2026-11-21T22:44:27Z","subjects":[],"languages":[],"rights":["Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/27076","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/27076","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F27076","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F27076","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ligrani, Phillip M."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School"]},{"key":"dc:contributor.school","label":"School","values":["Naval Postgraduate School"]},{"key":"dc:creator","label":"Author","values":["Wigle, James Michael"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-01-23T22:09:12Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-01-23T22:09:12Z"]},{"key":"dc:date.issued","label":"Date","values":["1991-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["compound angle injection","film-cooling","turbulent boundary layer"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/27076"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Experimental results are presented which describe the development and structure of flow downstream of one row and downstream of two staggered rows of film-cooling holes with compound angle orientations. Results presented include distributions of iso-energetic Stanton number ratios, and adiabatic film-cooling effectiveness deduced from Stanton numbers using superposition. Also presented are plots showing the streamwise development of injectant distributions and streamwise development of mean velocity distributions. Spanwise averaged values of the adiabatic film-cooling effectiveness are highest for blowing ratio m=0.5 and decrease as blowing ratio increases for x/d less than 20. At farther downstream positions, spanwise averaged effectiveness values increase with blowing ratio, except for data obtained downstream of two rows of holes with a blowing ratio of 3.0 and data obtained downstream of two rows of holes with a blowing ratio of 3.0 and data obtained downstream of one row of holes with a blowing ratio of 4.0, where severe lift-off of injectant occurs. Spanwise averaged iso-energetic Stanton number ratios range between 1.0 and 1.4 and show little variation as x/d increases for each value of blowing ratio, however for each x/d, values increase with increasing blowing ratio."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/heattransferdiab1094527076"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["244 p.;28 cm."]},{"key":"dc:title","label":"Title","values":["Heat transfer, adiabatic effectiveness and injectant distribution downstream of single and double rows of film-cooling holes with compound angles."]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant Commander, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ligrani, Phillip M."],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["Naval Postgraduate School"],"dc:contributor.school":["Naval Postgraduate School"],"dc:creator":["Wigle, James Michael"],"dc:date.accessioned":["2013-01-23T22:09:12Z"],"dc:date.available":["2013-01-23T22:09:12Z"],"dc:date.issued":["1991-12"],"dc:description.abstract":["Experimental results are presented which describe the development and structure of flow downstream of one row and downstream of two staggered rows of film-cooling holes with compound angle orientations. Results presented include distributions of iso-energetic Stanton number ratios, and adiabatic film-cooling effectiveness deduced from Stanton numbers using superposition. Also presented are plots showing the streamwise development of injectant distributions and streamwise development of mean velocity distributions. Spanwise averaged values of the adiabatic film-cooling effectiveness are highest for blowing ratio m=0.5 and decrease as blowing ratio increases for x/d less than 20. At farther downstream positions, spanwise averaged effectiveness values increase with blowing ratio, except for data obtained downstream of two rows of holes with a blowing ratio of 3.0 and data obtained downstream of two rows of holes with a blowing ratio of 3.0 and data obtained downstream of one row of holes with a blowing ratio of 4.0, where severe lift-off of injectant occurs. Spanwise averaged iso-energetic Stanton number ratios range between 1.0 and 1.4 and show little variation as x/d increases for each value of blowing ratio, however for each x/d, values increase with increasing blowing ratio."],"dc:description.uri":["http://archive.org/details/heattransferdiab1094527076"],"dc:format.extent":["244 p.;28 cm."],"dc:identifier.uri":["https://hdl.handle.net/10945/27076"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["Approved for public release; distribution is unlimited."],"dc:subject.keyword":["compound angle injection","film-cooling","turbulent boundary layer"],"dc:title":["Heat transfer, adiabatic effectiveness and injectant distribution downstream of single and double rows of film-cooling holes with compound angles."],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant Commander, United States Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T22:44:27Z"}